Bộ điều khiển bù công suất phản kháng JKW
Bộ điều khiển bù công suất phản kháng JKW

Bộ điều khiển bù công suất phản kháng JKW

Mã sản phẩm: Dòng JKWD
Bộ điều khiển bù công suất phản kháng tự động.
Số lượng đặt hàng tối thiểu: 100 chiếc
Thời gian giao hàng: 7–15 ngày

What Is Power Compensation Controller?

The ZHIMING JKWD Series JKW Reactive Power Compensation Controller is an intelligent auto-compensation device designed for self-regulating capacitor banks in low-voltage distribution systems. Based on full digital AC sampling technology, this Reactive Power Compensation Controller uses reactive power as the primary controlling physical quantity to achieve high-precision power factor correction. It enhances power transformer operating efficiency, reduces line losses, and improves voltage regulation — ultimately increasing ROI and grid reliability. With support for 1 to 12 output loops, dual manual/automatic working modes, and comprehensive digital display of power factor, reactive power, voltage, and current (primary side), the JKW Controller provides a complete solution for power quality management in industrial and commercial electrical networks.

Code And Implication of the Power Compensation Controller

JKW Reactive Power Compensation Controller(code)

Working Conditions of the JKW Reactive Power Compensation Controller

Thông số kỹ thuật sản phẩm

Tham sốThông số kỹ thuật
Điện áp định mứcAC 380V +10% (IEC 60038)
Dòng điện định mứcAC 0–5A (max. continuous)
Tần số định mức50 Hz ±51 TP3T
Tham số điều khiển
Sensitivity100mA (dòng điện hoạt động tối thiểu)
Target PF Setting0.70–0.99 (adjustable, 0.01 resolution; factory default: 0.98)
Switching DelayTransient mode: 0.5ms–200s; Steady-state mode: 2–200s
CT Ratio Range50:5 đến 3000:5 (độ phân giải 1:1; cài đặt mặc định của nhà sản xuất: 500:5)
Output CapacityTransient: DC 12V @ 50mA/channel; Steady-state: 380V AC @ 7A/channel or 200V AC @ 5A/channel
Độ chính xác của phép đo
Điện ápLoại 1.0 (±1,01 TP3T khi đọc)
Hiện tạiLoại 1.0 (±1,01 TP3T khi đọc)
Hệ số công suất±1,01 TP3T
Công suất phản khángLoại 2.0 (±2,01 TP3T khi đọc)
JKW Reactive Power Compensation Controller(diagram)

Kích thước sản phẩm

Kích thước lỗ cắt trên bảng điều khiển

Mô hình bộ điều khiểnKích thước lỗ cắt (Cao × Rộng)Sự khoan dungLưu ý khi lắp đặt
JKWD5-16138,0 × 138,0 mm±0,5 mmLỗ khoét hình vuông với bán kính ≤0,5 mm tại các góc
JKWD5113,0 × 113,0 mm±0,5 mmĐộ dày tấm tối đa: 3,0 mm

Yêu cầu cài đặt quan trọng:

1.Surface Flatness: ≤0.5 mm across cutout area
2. Bề mặt cạnh: Không có gờ (Ra tối đa 6,3 μm)
3. Khoảng trống: ≥20 mm phía sau tấm ốp để lắp đặt đầu nối dây
4. Chống thấm: Sử dụng miếng đệm IP54 (đi kèm) khi sử dụng trong môi trường ô nhiễm

Engineering Drawing Notation:

JKWD5-16         
  Ø4,3 × 4 M4      
  Lỗ lắp đặt  
  (thông thường) 

Hình 1: Kích thước cắt tiêu chuẩn với vị trí các bulông M4 (tất cả các kích thước tính bằng mm)

Why Choose ZHIMING's Power Compensation Controller?

Full Digital Control & High-Precision PF Regulation

The JKW Reactive Power Compensation Controller adopts AC sampling technology with digital integration and filtration, making it insensitive to harmonic interference. Using reactive power as the primary controlling physical quantity, it achieves high-precision automatic power factor correction with adjustable target PF from 0.70 to 0.99.

Intelligent Switching Optimization & Extended System Life

An optimized automatic control scheme minimizes unnecessary capacitor switching cycles — reducing contactor wear and extending the service life of the entire compensation system. Built-in over-voltage and under-voltage judgment with fast cutoff protects capacitor banks from abnormal voltage conditions, while the configurable 200-second re-insertion delay ensures complete capacitor discharge before reconnection.

Strong Anti-Interference & Data Protection

Capable of withstanding up to 2000V interference pulses from the direct power supply, this Reactive Power Compensation Controller maintains stable operation without crashing or losing data. All control parameters are stored in non-volatile memory, ensuring data integrity even during power failures.

Flexible Configuration & User-Friendly Operation

Equipped with both manual and automatic working modes, the controller supports easy on-site commissioning and debugging. The digital display provides real-time readout of power factor, reactive power, voltage, and current (primary side), while the current sampling input resistance below 0.05Ω allows direct connection from measuring loops without additional signal conditioning.

Câu hỏi thường gặp

What is the main purpose of this Reactive Power Compensation Controller?

The JKW Reactive Power Compensation Controller automatically regulates capacitor banks in low-voltage distribution systems to maintain the target power factor. By minimizing reactive power drawn from the grid, it improves transformer efficiency, reduces line losses, and lowers electricity costs while enhancing overall voltage stability.

The JKWD Series supports 1 to 12 output loops, configurable based on the compensation system size. Each loop can operate in either transient mode (DC 12V @ 50mA) or steady-state mode (AC 380V @ 7A / AC 220V @ 5A), accommodating various contactor and thyristor switching configurations.

Yes. The target power factor is programmable from 0.70 to 0.99 with 0.01 resolution (factory default: 0.98). All control parameters — including CT ratio (50:5 to 3000:5), switching delay, and sensitivity — are fully adjustable via the digital interface and retained in non-volatile memory after power-off.

The controller continuously monitors voltage and automatically executes fast cutoff of capacitor banks when over-voltage or under-voltage is detected, preventing capacitor damage. The built-in re-insertion delay (configurable up to 200 seconds per capacitor group) ensures complete discharge before reconnection, reducing inrush current impact on the electrical network.

The AC sampling and digital integration technology makes the controller insensitive to harmonic distortion, ensuring accurate reactive power measurement even in electrically noisy environments. Combined with the <0.05Ω current sampling input resistance, it delivers reliable Class 1.0 voltage/current accuracy and ±1.0% power factor precision without requiring external signal conditioners.

Hãy liên hệ với chúng tôi, chúng tôi sẽ đáp ứng mọi nhu cầu của bạn.

Hơn 30 năm cống hiến không ngừng,
Thúc đẩy sự phát triển, nâng cao chất lượng cuộc sống.

Liên hệ ngay
Vui lòng bật JavaScript trong trình duyệt của bạn để hoàn tất biểu mẫu này.

Liên hệ với chúng tôi ngay!

Vui lòng bật JavaScript trong trình duyệt của bạn để hoàn tất biểu mẫu này.