Controlador de compensación de potencia reactiva JKW
Controlador de compensación de potencia reactiva JKW

Controlador de compensación de potencia reactiva JKW

N.º de modelo: Serie JKWD
Controlador de compensación automática de potencia reactiva.
Pedido mínimo: 100 unidades
Plazo de entrega: 7-15 días

What Is Power Compensation Controller?

The ZHIMING JKWD Series JKW Reactive Power Compensation Controller is an intelligent auto-compensation device designed for self-regulating capacitor banks in low-voltage distribution systems. Based on full digital AC sampling technology, this Reactive Power Compensation Controller uses reactive power as the primary controlling physical quantity to achieve high-precision power factor correction. It enhances power transformer operating efficiency, reduces line losses, and improves voltage regulation — ultimately increasing ROI and grid reliability. With support for 1 to 12 output loops, dual manual/automatic working modes, and comprehensive digital display of power factor, reactive power, voltage, and current (primary side), the JKW Controller provides a complete solution for power quality management in industrial and commercial electrical networks.

Code And Implication of the Power Compensation Controller

JKW Reactive Power Compensation Controller(code)

Working Conditions of the JKW Reactive Power Compensation Controller

Parámetros del producto

ParámetroEspecificaciones
Tensión nominalCA 380 V +10% (IEC 60038)
Corriente nominalAC 0–5A (max. continuous)
Frecuencia nominal50 Hz ±51 TP3T
Parámetros de control
Sensitivity100 mA (corriente mínima de funcionamiento)
Target PF Setting0.70–0.99 (adjustable, 0.01 resolution; factory default: 0.98)
Switching DelayTransient mode: 0.5ms–200s; Steady-state mode: 2–200s
CT Ratio Range50:5 a 3000:5 (resolución 1:1; valor predeterminado de fábrica: 500:5)
Output CapacityTransient: DC 12V @ 50mA/channel; Steady-state: 380V AC @ 7A/channel or 200V AC @ 5A/channel
Precisión de medición
VoltajeClase 1.0 (±1,01 TP3T de lectura)
ActualClase 1.0 (±1,01 TP3T de lectura)
Factor de potencia±1,01 TP3T
Potencia reactivaClase 2.0 (±2,01 TP3T de lectura)
JKW Reactive Power Compensation Controller(diagram)

Tamaño del producto

Dimensiones del recorte del panel

Modelo de controladorDimensiones del recorte (alto × ancho)ToleranciaNotas de montaje
JKWD5-16138,0 × 138,0 mm±0,5 mmRecorte cuadrado con un radio ≤0,5 mm en las esquinas
JKWD5113,0 × 113,0 mm±0,5 mmEspesor máximo del panel: 3,0 mm

Requisitos de instalación imprescindibles:

1.Surface Flatness: ≤0.5 mm across cutout area
2. Acabado de los bordes: sin rebabas (máx. Ra 6,3 μm)
3. Espacio libre: ≥20 mm detrás del panel para la conexión de los cables
4. Sellado: Utilice una junta IP54 (incluida) cuando se utilice en entornos contaminados

Engineering Drawing Notation:

JKWD5-16         
  Ø4,3 × 4 M4      
  Orificios de montaje  
  (típico) 

Fig. 1: Recorte estándar con posiciones de los tornillos M4 (todas las dimensiones en mm)

Why Choose ZHIMING's Power Compensation Controller?

Full Digital Control & High-Precision PF Regulation

The JKW Reactive Power Compensation Controller adopts AC sampling technology with digital integration and filtration, making it insensitive to harmonic interference. Using reactive power as the primary controlling physical quantity, it achieves high-precision automatic power factor correction with adjustable target PF from 0.70 to 0.99.

Intelligent Switching Optimization & Extended System Life

An optimized automatic control scheme minimizes unnecessary capacitor switching cycles — reducing contactor wear and extending the service life of the entire compensation system. Built-in over-voltage and under-voltage judgment with fast cutoff protects capacitor banks from abnormal voltage conditions, while the configurable 200-second re-insertion delay ensures complete capacitor discharge before reconnection.

Strong Anti-Interference & Data Protection

Capable of withstanding up to 2000V interference pulses from the direct power supply, this Reactive Power Compensation Controller maintains stable operation without crashing or losing data. All control parameters are stored in non-volatile memory, ensuring data integrity even during power failures.

Flexible Configuration & User-Friendly Operation

Equipped with both manual and automatic working modes, the controller supports easy on-site commissioning and debugging. The digital display provides real-time readout of power factor, reactive power, voltage, and current (primary side), while the current sampling input resistance below 0.05Ω allows direct connection from measuring loops without additional signal conditioning.

Preguntas frecuentes

What is the main purpose of this Reactive Power Compensation Controller?

The JKW Reactive Power Compensation Controller automatically regulates capacitor banks in low-voltage distribution systems to maintain the target power factor. By minimizing reactive power drawn from the grid, it improves transformer efficiency, reduces line losses, and lowers electricity costs while enhancing overall voltage stability.

The JKWD Series supports 1 to 12 output loops, configurable based on the compensation system size. Each loop can operate in either transient mode (DC 12V @ 50mA) or steady-state mode (AC 380V @ 7A / AC 220V @ 5A), accommodating various contactor and thyristor switching configurations.

Yes. The target power factor is programmable from 0.70 to 0.99 with 0.01 resolution (factory default: 0.98). All control parameters — including CT ratio (50:5 to 3000:5), switching delay, and sensitivity — are fully adjustable via the digital interface and retained in non-volatile memory after power-off.

The controller continuously monitors voltage and automatically executes fast cutoff of capacitor banks when over-voltage or under-voltage is detected, preventing capacitor damage. The built-in re-insertion delay (configurable up to 200 seconds per capacitor group) ensures complete discharge before reconnection, reducing inrush current impact on the electrical network.

The AC sampling and digital integration technology makes the controller insensitive to harmonic distortion, ensuring accurate reactive power measurement even in electrically noisy environments. Combined with the <0.05Ω current sampling input resistance, it delivers reliable Class 1.0 voltage/current accuracy and ±1.0% power factor precision without requiring external signal conditioners.

Contáctanos, damos respuesta a tus necesidades.

Más de 30 años de compromiso constante,
Impulsando el progreso, empoderando vidas.

Contáctenos ahora
Por favor, active JavaScript en su navegador para completar este formulario.

¡Contáctanos ahora!

Por favor, active JavaScript en su navegador para completar este formulario.