A Zero Sequence Current Transformer (ZSCT) , also called a core balance CT or residual current CT, detects ground fault currents in three-phase systems. Unlike standard CTs on individual phases, a ZSCT encircles all three phase conductors (and neutral if present). Under normal balanced conditions, the vector sum of currents equals zero. When a ground fault occurs, the unbalanced current produces a secondary output proportional to the fault current. This signal goes to a protection relay (e.g., 50N/51N or 50G/51G) which trips the breaker. Typical applications include solidly grounded, low-resistance grounded, or high-resistance grounded systems from 120V to 35kV.
| Chức năng | Mô tả |
|---|---|
| Ground Fault Detection | Senses residual current from 50mA to 100% of rated primary current. Outputs analog signal (mA or A) to relay. |
| High-Impedance Fault Identification | Detects low-magnitude faults (e.g., 1–5A) that standard overcurrent relays may miss. |
| Directional Ground Fault Indication | When paired with voltage reference, helps locate fault direction on radial systems. |
| Harmonic Filtering (Built-in) | Some models include low-pass filtering to ignore high-frequency noise (e.g., from VFDs) above 300Hz. |
| Split-Core for Retrofit | Allows installation without disconnecting primary cables. Hinged or U-shape design. |
| Relay Interface | Provides 5A or 1A secondary output (standard) or 0–10V output for electronic relays. |
This table helps engineers and procurement teams quickly match the right zero sequence current transformer to their system requirements.
| Tham số | Typical Range / Value |
|---|---|
| Primary Current (Residual) | 1A to 1000A (continuous); 10× rated for 1 second |
| Secondary Output | 5A, 1A, 0.333V, 0–10V (selectable by model) |
| Inner Diameter | 30mm, 60mm, 100mm, 150mm, 200mm, 300mm |
| Core Material | Nanocrystalline (for low current) or silicon steel (for high current) |
| Accuracy Class | 1, 3, 5 (per IEC 61869-2 or IEEE C57.13) |
| Tần số | 50/60 Hz (wideband version up to 400Hz) |
| Max Voltage | 720V AC (low voltage) / 35kV (medium voltage with insulation) |
| Nhiệt độ hoạt động | -25°C to +70°C |
| Enclosure Rating | IP20 (indoor) / IP65 (outdoor with seal kit) |
| Dielectric Withstand | 3kV for 1 minute (primary to secondary) |
| Mounting | Panel mount, busbar mount, or cable clamp |
Where a Zero Sequence Current Transformer Solves Ground Fault Blind Spots
A standard phase CT won’t tell you if a motor winding is leaking 2A to ground. A Biến áp dòng điện chuỗi không catches exactly that. Below are typical installations where our ZSCT helps locate arcing ground faults before they cause a fire, works with existing relays (GE, SEL, ABB), and eliminates nuisance trips caused by leakage currents in cable shielding.
Uses nanocrystalline or high-permeability silicon steel. Detects residual currents as low as 10mA. This Zero Sequence Current Transformer maintains linearity from 1mA to 200A, covering both leakage and fault ranges.
Built-in electrostatic and magnetic shielding. Reduces false trips caused by nearby busbars or motors. A reliable Zero Sequence Current Transformer must reject common-mode noise — ours achieves >60dB rejection at 50Hz.
Available from 30mm to 300mm opening. Fits single cables, busbars, or multiple conductors. You don’t need to disconnect cables; the split-core version clamps around existing wiring in under 2 minutes.
Rated for -25°C to +70°C continuous. No phase shift drift over 20 years. This Zero Sequence Current Transformer uses low-loss material, so accuracy remains ±1% from -10°C to +60°C.
Same mounting holes as ABB, SEL, or GE models. Direct replacement without drilling new holes. Comes with standard 4-meter twisted pair leads; extension up to 100m without signal degradation.
Every unit is tested with a primary injection report. ZHIMING engineers help with relay matching. We also provide a free sizing tool — just enter cable diameter and fault current, and the correct Zero Sequence Current Transformer is selected automatically.
Một nhà sản xuất tụ điện công suất hàng đầu với hơn 25 năm kinh nghiệm sẵn sàng giải đáp mọi thắc mắc của quý khách — bao gồm các vấn đề liên quan đến sản phẩm, câu hỏi về kinh doanh hoặc các vấn đề liên quan đến dịch vụ.
Vẫn còn thắc mắc? Chúng tôi luôn sẵn sàng hỗ trợ bạn
Bạn chưa tìm thấy thứ mình cần?
Liên hệ với chúng tôi bất cứ lúc nào
Yes. For solidly grounded systems, the ZSCT detects low-level ground faults (e.g., 5–20A). Choose a lower ratio (e.g., 50:5) for better sensitivity.
A ZSCT has one core encircling all phases, giving better balance and higher accuracy for low currents (<5% of CT rating). Three-CT residual method has larger errors due to phase CT mismatch.
Yes, but select secondary output accordingly: 5A for electromechanical (e.g., GE IAC), 1A or 0.333V for electronic relays. Our model has dual taps.
Use a ZSCT with a higher pickup threshold (e.g., 500mA instead of 100mA) or add a time delay (0.5–1s) in the relay. Do not filter below 50Hz.
Minor eccentricity (<10% of ID) has negligible effect on accuracy for fault-level currents (>1A). For low-level leakage (<100mA), keep conductors roughly centered to avoid stray field errors.