Pengukur Tegangan Fase Tunggal Digital
Pengukur Tegangan Fase Tunggal Digital

Pengukur Tegangan Fase Tunggal Digital

Model No: ZM – V, DV Series
This device offers high-precision AC/DC voltage measurement, programmable settings, multi-interface support (RS-485, analog, switch I/O), wide-range power supply, and versatile form factors for various cabinet applications.
Pesanan Minimum: 100 buah
Waktu Stok: 7-15 Hari

What Is Single-phase Voltage Meter?

The ZHIMING ZM-V, DV Series Digital Single-phase Voltage Meter delivers high-precision single-phase AC and DC voltage measurement with a digital display and local data query function, making it a reliable choice for real-time power monitoring. It features programmable voltage ratio settings, RS-485 communication using Modbus-RTU protocol, and supports switch input/output and analog signal output for flexible system integration. With a wide-range auxiliary power supply of AC/DC 80V–270V or AC 220V and multiple form factor options, this Digital Single-phase Voltage Meter adapts to various cabinet layouts in industrial and commercial applications.

Code And Implication of the Single-phase Voltage Meter

Digital Single-phase Voltage Meter(code)

Main Technical Schematic of the Single-phase Voltage Meter

Catatan: Model spesifikasi khusus lainnya disediakan sesuai dengan kebutuhan pengguna

Working Conditions of the Single-phase Voltage Meter

Parameter Produk

ParameterSpesifikasi
AkurasiVoltage: Class 0.5
Catu Daya TambahanAC/DC 80V–270V, AC 220V; Power consumption <4VA
Antarmuka Komunikasi1× RS-485, Modbus-RTU protocol; Baud rate 1200–9600 bps (default 2400 bps)
Switch Input2 dry contact inputs
Switch Output2 relay outputs, AC 250V/5A, DC 30V/5A
Analog Output1× 0/4–20mA or 0–5/10V
Connection ModeSingle phase
Tegangan PengenalAC 57.7V, 100V, 220V, 380V; DC 2V, 20V, 200V, 600V
Kapasitas Kelebihan Beban1.2× rated continuous, 2× rated / 1s instantaneous
Signal Power Consumption<1VA per phase
Input Impedance>300kΩ
Frequency Range45–65Hz
Resistensi Isolasi>100MΩ
AC Withstand VoltageAC 2kV
Electrostatic Discharge (ESD)Class 4
Electrical Fast Transient BurstClass 4
Surge (Impact)Class 4

Why Choose ZHIMING's Single-phase Voltage Meter?

Class 0.5 High-Precision Measurement

The Digital Single-phase Voltage Meter delivers Class 0.5 accuracy for both AC and DC single-phase voltage measurement, providing reliable data for power monitoring and control applications.

Multi-Interface Integration

With RS-485 Modbus-RTU communication, dual switch inputs, dual relay outputs, and an analog output channel (0/4–20mA or 0–5/10V), this Digital Single-phase Voltage Meter connects directly to PLCs, SCADA, and energy management platforms without extra signal converters.

Wide-Range Power Supply & Rugged Reliability

An ultra-wide auxiliary power input of AC/DC 80V–270V or AC 220V ensures stable operation under fluctuating supply conditions, while Class 4 EMC immunity, >100MΩ insulation resistance, and AC 2kV withstand voltage guarantee dependable performance in harsh industrial environments.

Flexible Installation & Standards Compliance

Multiple form factors suit various cabinet layouts for simplified panel integration. Fully compliant with GB/T 22264.1-2008 and GB/T 22264.7-2008, backed by competitive factory pricing (MOQ 100 pieces) and dedicated engineering support.

PERTANYAAN YANG SERING DIAJUKAN

What voltage types can this Digital Single-phase Voltage Meter measure??

The ZM-V, DV Series supports both single-phase AC voltage (57.7V, 100V, 220V, 380V) and DC voltage (2V, 20V, 200V, 600V). The rated input range covers common low-voltage distribution and control circuit requirements, with an overload capacity of 1.2× continuous and 2× instantaneous.

The Digital Single-phase Voltage Meter features one RS-485 communication channel operating on the Modbus-RTU protocol. The baud rate is configurable from 1200 to 9600 bps (default 2400 bps), allowing it to connect directly to PLCs, HMIs, SCADA systems, and energy management platforms for remote data reading and parameter configuration.

Yes. In addition to the RS-485 digital interface, this Digital Single-phase Voltage Meter provides one analog output channel (0/4–20mA or 0–5/10V, programmable) and two relay outputs (AC 250V/5A, DC 30V/5A) for alarm signaling or load control. Two dry contact switch inputs are also available for status monitoring or external trigger functions.

The Digital Single-phase Voltage Meter is offered in multiple form factors to fit various panel and cabinet layouts. Please refer to the Specification & Dimensions section or contact ZHIMING’s engineering team with your cabinet dimensions for the most suitable model recommendation.

The meter operates reliably in ambient temperatures from -10°C to +55°C, with storage tolerance from -25°C to +70°C. Relative humidity should not exceed 93% without corrosive gases, and installation altitude is limited to 2500m maximum.

Hubungi kami, kami memenuhi kebutuhan Anda.

Komitmen terfokus selama lebih dari 30 tahun,
Mendorong kemajuan, memberdayakan kehidupan.

Hubungi sekarang