Zhiming Group fokus pada komponen tegangan tinggi dan rendah serta peralatan lengkap. Kebutuhan Anda adalah titik awal, dan kami merancang dan menyesuaikan produksi untuk memastikan bahwa setiap peralatan dibuat untuk memenuhi kebutuhan daya Anda.
Memaksimalkan Efisiensi & Faktor Daya
A High Voltage Capacitor Contactor is an electrically operated switching device specifically designed for energizing and de-energizing capacitor banks in high-voltage power systems (typically 1kV to 35kV). Unlike ordinary contactors, it incorporates pre-insertion resistors or damping circuits to suppress inrush current and overvoltage during capacitor switching. This component is critical for power factor correction, voltage regulation, and harmonic filtering in industrial and utility substations.
| Fungsi | Typical Performance / Data |
|---|---|
| Inrush current suppression | Peak limited to ≤ 50× rated current (or < 100× depending on design) |
| Switching frequency | Up to 10–30 operations per hour (depending on capacitor size) |
| Dielectric withstand | Main circuit: 2.5× rated voltage (1 min); Control circuit: 2kV |
| Daya tahan mekanis | 500,000 – 1,000,000 operations |
| Electrical endurance | 100,000 – 200,000 operations under rated conditions |
| Kisaran suhu sekitar | -25°C to +55°C (derating may apply above 40°C) |
This table helps engineers and procurement teams quickly match the right high voltage capacitor contactor to their system requirements.
| Parameter | Common Value Range |
|---|---|
| Rated voltage (Ue) | 3.6kV, 7.2kV, 12kV, 24kV, 36kV |
| Rated current (Ie) | 400A – 1250A (for capacitor switching) |
| Capacitor bank power | 50 kvar – 2000 kvar |
| Short-circuit withstand (Icw) | 10kA – 31.5kA for 1 second |
| Control voltage (Us) | AC 110V, 220V, 230V, 400V / DC 24V, 48V, 110V, 220V |
| Nilai resistor pra-penyisipan | 50Ω – 200Ω (typically) |
| Closing time | 30 – 80 ms |
| Opening time | 30 – 60 ms |
| Coil power consumption | 50 – 300 VA (sealed) |
| Kelas perlindungan | IP20 (cabinet), IP54 (optional) |
Where a high voltage capacitor contactor makes the difference
Switching power factor correction capacitors isn’t a one-size-fits-all job. A high voltage capacitor contactor is the key to handling tough conditions. Below are real-world cases where this component cuts inrush spikes, protects capacitor life, and ensures stable voltage during reactive power compensation.
Limits inrush current to safe levels, extending capacitor bank lifespan by up to 40%. Even under back‑to‑back capacitor switching, our High Voltage Capacitor Contactor keeps peak current below 50× rated value, which most standard units cannot guarantee.
eliably interrupts capacitive loads without restrike, even under voltage fluctuation. This chamber design uses magnetic blow‑out technology, making ZHIMING’s High Voltage Capacitor Contactor suitable for systems with unstable grid voltage or frequent daily operations.
From 3.6kV to 36kV / 50 to 2000 kvar, matching most substation and industrial needs. Instead of stocking multiple models, a single High Voltage Capacitor Contactor series from ZHIMING covers both medium‑voltage motor centers and large capacitor bank panels.
Reduces coil holding power by over 80%, lowering panel heat and energy waste. For projects that prioritize energy efficiency, this High Voltage Capacitor Contactor draws power only during switching transitions, keeping the control cabinet cool without external fans.
Proven durability for automatic capacitor banks that switch dozens of times per day. Field data shows that after three years of continuous use, this High Voltage Capacitor Contactor still operates with contact resistance below factory limits, while ordinary contactors often fail within months.
Mounting dimensions and control terminals align with common European and Asian contactor footprints. Engineers can replace an aging competitor’s High Voltage Capacitor Contactor in under 30 minutes without drilling new holes or rewriting control schematics, reducing downtime significantly.
Produsen kapasitor daya terkemuka dengan pengalaman lebih dari 25 tahun siap menjawab semua pertanyaan Anda-meliputi masalah terkait produk, pertanyaan bisnis, atau masalah terkait layanan.
Masih Ada Pertanyaan? Kami Siap Membantu
Tidak menemukan yang Anda cari?
Hubungi Kami Kapan Saja
No. Standard contactors lack pre‑insertion resistors and proper arc extinguishing for capacitive loads, leading to contact welding and premature failure.
Match the contactor’s rated current (Ie) to at least 1.3× the capacitor’s fundamental current. Also verify the inrush current suppression rating and short‑circuit withstand.
Periodically check contact erosion, resistor integrity, and coil insulation. For frequent switching (e.g., >20 times/day), inspect every 6 months.
Yes, ZHIMING models are designed for up to 20% harmonic current distortion. For high‑harmonic environments (e.g., variable‑speed drives), a series reactor should be added.
AC 110V, 220V, 230V, 400V (50/60Hz) and DC 24V, 48V, 110V, 220V. Low‑power DC versions are ideal for PLC‑based automatic power factor controllers.
Hubungi kami, kami memenuhi kebutuhan Anda.
Komitmen terfokus selama lebih dari 30 tahun,
Mendorong kemajuan, memberdayakan kehidupan.