The ZM-AA/DA digital ammeter series measures single-phase AC or DC current with high accuracy. It features a bright 7-segment display, programmable CT/shunt ratio, RS-485 (Modbus-RTU), optional digital I/O, and analog retransmission (4–20 mA/voltage), wide-range auxiliary power, and multiple panel sizes (48/72/96 mm) to fit different switchgear and PFC cabinets.

Technical Index

Accuracy of measurement

Current: class 0.5

Signal input

Connection mode: Single phase

Rated current :AC 1A, AC 5A, DC 20mA, DC 1A, DC5A, DC 75mV

Overload: 1.2 times (Continued), 10times for/5 seconds (instantaneous)

Power consumption:<0.4VA/phase

Impedance:<20mΩ

Frequency: 45~65Hz 

Auxiliary power supply

Working range: AC/DC 80V~270V, AC220V

Power consumption:<4VA

Function Module

Communication interface 1 way RS-485 communication, Modbus-RTU protocol 

baud rate:1200~9600bps, the default 2400bps

Switch input: support 2 stem node input

Switch output: supports 2 relay outputs, capacity: AC 250V/5A, DC 30V/5A

Transmission output: supports 1 analog

output: 0/4~20mAor 0~5/10V

Environment

Working temperature: -10℃~+55℃

Storage temperature: -25℃~+70℃

Relative humidity is less than 93%, no corrosive gas

Altitude: 2500m

Safety

Insulation resistance : >100MΩ

AC withstand voltage: AC 2KV

1. High precision to measure single-phase alternating current or DC current

2. Provide the digital tube display, local data query

3. Current ratio programmable settings

4. Support for RS-485 communication, Modbus-RTU protocol

5. Support for switching input, output, and analog quantity transmitting output

6. Auxiliary power supply: AC/DC 80V~270V, AC220V

7. A variety of shapes, to meet the different requirements of the cabinet body electric circuit

Electromagnetic compatibility

ESD: Class 4

Electrical fast transient burst: Class 4

Surge(impact): Class 4

Outline Dimensions

12.jpg

Performance Characteristics

1. High precision to measure single-phase alternating current or DC current

2. Provide the digital tube display, local data query

3. Current ratio programmable settings

4. Support for RS-485 communication, Modbus-RTU protocol

5. Support for switching input, output, analog quantity transmitting output

6. Auxiliary power supply: AC/DC 80V~270V , AC220V

7. A variety of shapes, to meet the different requirements of the cabinet body electric circuit

Hubungi kami, kami memenuhi kebutuhan Anda.

Komitmen terfokus selama lebih dari 30 tahun,
Mendorong kemajuan, memberdayakan kehidupan.

Hubungi sekarang
Harap aktifkan JavaScript di browser Anda untuk mengisi formulir ini.