Zhiming Group fokus pada komponen tegangan tinggi dan rendah serta peralatan lengkap. Kebutuhan Anda adalah titik awal, dan kami merancang dan menyesuaikan produksi untuk memastikan bahwa setiap peralatan dibuat untuk memenuhi kebutuhan daya Anda.
Memaksimalkan Efisiensi & Faktor Daya
A low voltage capacitor contactor is an electromagnetic switching device specifically engineered for the safe connection and disconnection of low voltage power factor correction capacitor banks (typically ≤1000 V AC). Unlike general-purpose contactors, a low voltage capacitor contactor integrates pre-insertion resistors or early-make auxiliary contacts that limit inrush current and suppress voltage transients during capacitor energization. This design prevents contact welding, reduces harmonic distortion, and ensures compliance with IEC 60947‑4‑1 standards. Low voltage capacitor contactors are the core switching elements in automatic power factor correction panels for industrial plants, commercial buildings, and utility substations.
| Fungsi | Data / Deskripsi Khas |
|---|---|
| Tegangan operasional terukur (Ue) | 220 V – 690 V AC (up to 1000 V available) |
| Rated frequency | 50 / 60 Hz |
| Capacitor switching capacity | 5 kvar – 100 kvar per contactor |
| Batasan arus masuk | ≤ 50× to 100× rated rms current |
| Nilai resistor pra-penyisipan | 1.5 Ω – 4.7 Ω (typical) |
| Waktu pra-penyisipan | 5 – 15 ms |
| Daya tahan mekanis | 1 - 2 juta operasi |
| Electrical endurance (AC‑6b) | 100.000 - 300.000 operasi |
| Kisaran suhu sekitar | -25 °C hingga +55 °C |
This table helps engineers and procurement teams quickly match the low voltage capacitor contactor to their system requirements.
| Parameter | Value Range / Example |
|---|---|
| Tegangan isolasi terukur (Ui) | 690 V – 1000 V |
| Nilai arus termal (Ith) | 25 A, 40 A, 63 A, 80 A, 125 A |
| Capacitor current (AC‑6b) | 20 A – 100 A (depending on model) |
| Switching power (400 V / 50 Hz) | 10 kvar, 15 kvar, 25 kvar, 50 kvar, 100 kvar |
| Pembatasan puncak arus lonjakan | ≤ 100 × I rms (with pre-insertion resistors) |
| Control coil voltage options | AC: 24 V, 110 V, 230 V, 400 V, 415 V; DC: 24 V, 110 V |
| Coil inrush VA | 50 – 150 VA |
| Coil sealing VA | 5 – 15 VA |
| Number of auxiliary contacts | 1 NO + 1 NC (standard), optional up to 2 NO+2 NC |
| Terminal protection degree | IP20 (dengan penutup) |
| Jenis pemasangan | 35 mm DIN rail or screw fixing |
| Standards compliance | IEC 60947‑4‑1, EN 60947‑4‑1, CE, RoHS |
Where Our Low Voltage Capacitor Contactor Delivers Proven Results with Power Factor Correction Capacitors
A low voltage capacitor contactor is not a one-size-fits-all switching device. Below are typical scenarios where our low voltage capacitor contactor, when combined with a power factor correction capacitor, reduces reactive energy penalties, improves voltage stability, and lowers harmonic distortion — by ensuring transient‑free switching and protecting both the capacitor and the network.
Designed specifically for ≤690 V AC networks, ensuring perfect compatibility with standard power factor correction panels.
Eliminates dangerous inrush currents and contact welding, extending capacitor life by up to 50%.
Rated for over 200,000 AC‑6b electrical operations under full capacitive load, our low voltage capacitor contactor delivers reliable performance even in harsh industrial environments with frequent switching cycles.
With sealed power consumption as low as 5–10 VA, this low voltage capacitor contactor minimizes panel internal heating and reduces standby energy costs, making it ideal for 24/7 automated power factor correction systems.
Available in AC control voltages from 24 V to 415 V (50/60 Hz) as well as DC options, ZHIMING‘s low voltage capacitor contactor accepts direct output from most PLCs, energy meters, and power factor controllers without external interface relays.
Certified to IEC 60947‑4‑1 and bearing CE marking, our low voltage capacitor contactor meets international safety and performance standards, ensuring worry‑free installation and global acceptance.
Produsen kapasitor daya terkemuka dengan pengalaman lebih dari 25 tahun siap menjawab semua pertanyaan Anda-meliputi masalah terkait produk, pertanyaan bisnis, atau masalah terkait layanan.
Masih Ada Pertanyaan? Kami Siap Membantu
Tidak menemukan yang Anda cari?
Hubungi Kami Kapan Saja
No. A standard contactor lacks pre-insertion resistors, causing inrush currents up to 200× the capacitor’s rated current. This leads to contact welding, harmonic resonance, and rapid failure. Always choose a dedicated low voltage capacitor contactor.
Match the contactor’s AC‑6b switching power (kvar) to your capacitor step size at the same voltage. For example, a 25 kvar capacitor at 400 V requires a low voltage capacitor contactor rated ≥ 25 kvar at 400 V. Add 20% margin if harmonics are present.
Under normal conditions (≤50 switching operations per day), a quality low voltage capacitor contactor can achieve 100,000–300,000 electrical operations, equivalent to 5–10 years of reliable service.
No. ZHIMING‘s low voltage capacitor contactors have built‑in pre‑insertion resistors, so no external damping components are needed. Simply wire the capacitor directly to the contactor output terminals.
Yes, provided the contactor is rated for the single‑phase voltage and current. However, most low voltage capacitor contactors are designed for three‑phase systems; for single‑phase applications, consult the wiring diagram or use three contactor poles in parallel.
Hubungi kami, kami memenuhi kebutuhan Anda.
Komitmen terfokus selama lebih dari 30 tahun,
Mendorong kemajuan, memberdayakan kehidupan.