Tek fazlı Dijital Pano Ampermetresi
Tek fazlı Dijital Pano Ampermetresi

Tek fazlı Dijital Pano Ampermetresi

The ZM-AA/DA digital ammeter series measures single-phase AC or DC current with high accuracy. It features a bright 7-segment display, programmable CT/shunt ratio, RS-485 (Modbus-RTU), optional digital I/O, and analog retransmission (4–20 mA/voltage), wide-range auxiliary power, and multiple panel sizes (48/72/96 mm) to fit different switchgear and PFC cabinets.

What Is Single-phase Digital Panel Ammeter?

The ZHIMING ZM-AA/DA Series Single-phase Digital Panel Ammeter delivers Class 0.5 high-precision measurement of single-phase AC and DC current with a bright 7-segment digital tube display and local data query function. It features programmable CT/shunt ratio settings, RS-485 communication using Modbus-RTU protocol, and supports switch input/output and analog retransmission (4–20mA or voltage) for flexible system integration. With a wide-range auxiliary power supply of AC/DC 80V–270V or AC 220V and multiple panel sizes including 48mm, 72mm, and 96mm, this Digital Panel Ammeter adapts to various switchgear, PFC cabinets, and electrical panel configurations.

Working Conditions of the Single-phase Digital Panel Ammeter

Ürün Parametreleri

ParametreŞartname
DoğrulukCurrent: Class 0.5
Connection ModeSingle phase
Nominal AkımAC 1A, AC 5A; DC 20mA, DC 1A, DC 5A, DC 75mV
Overload Capacity1.2× rated continuous, 10× rated / 5s instantaneous
Signal Power Consumption<0.4VA per phase
Impedance<20mΩ
Frequency Range45–65Hz
Auxiliary Power SupplyAC/DC 80V–270V, AC 220V; Power consumption <4VA
İletişim Arayüzü1× RS-485, Modbus-RTU protocol; Baud rate 1200–9600 bps (default 2400 bps)
Switch Input2 dry contact inputs
Switch Output2 relay outputs, AC 250V/5A, DC 30V/5A
Analog Output1× 0/4–20mA or 0–5/10V
İzolasyon Direnci>100MΩ
AC Withstand VoltageAC 2kV
Electrostatic Discharge (ESD)Class 4
Electrical Fast Transient BurstClass 4
Surge (Impact)Class 4
Single-phase Digital Panel Ammeter(dimensions)

Why Choose ZHIMING's Single-phase Digital Panel Ammeter?

Class 0.5 High-Precision Current Measurement

The Single-phase Digital Panel Ammeter achieves Class 0.5 accuracy for both AC and DC current measurement, supporting a wide rated input range from AC 1A/5A to DC 20mA/1A/5A/75mV shunt input.

Multi-Interface Communication & I/O

Equipped with RS-485 Modbus-RTU communication, dual switch inputs, dual relay outputs (AC 250V/5A, DC 30V/5A), and one analog retransmission channel (0/4–20mA or 0–5/10V), this Digital Panel Ammeter integrates seamlessly into automation and SCADA systems.

Wide-Range Power Supply & EMC Protection

An ultra-wide auxiliary power input of AC/DC 80V–270V or AC 220V ensures reliable operation under fluctuating supply conditions, while Class 4 EMC immunity (ESD, EFT, Surge), >100MΩ insulation resistance, and AC 2kV withstand voltage guarantee stable performance in harsh electrical environments.

Flexible Panel Sizes & Easy Installation

Available in three standard panel sizes — 48mm, 72mm, and 96mm — this Digital Panel Ammeter fits diverse switchgear, PFC cabinets, and control panel cutouts. The 7-segment LED display and local data query function enable quick on-site reading without additional tools or software.

SSS

What current types and ranges can this Single-phase Digital Panel Ammeter measure?

The ZM-AA/DA Series supports single-phase AC current (1A, 5A) and DC current (20mA, 1A, 5A, 75mV shunt input). The CT or shunt ratio is programmable, allowing the display to scale to virtually any primary current range for flexible application in different metering scenarios.

The ammeter features one RS-485 channel operating on the Modbus-RTU protocol, with configurable baud rates from 1200 to 9600 bps (default 2400 bps). It connects directly to PLCs, HMIs, and energy management platforms for remote monitoring, data logging, and parameter configuration.

The Single-phase Digital Panel Ammeter comes in three standard form factors: 48mm, 72mm, and 96mm panel cutout sizes, covering most common switchgear, PFC cabinet, and control panel requirements.

Yes. In addition to RS-485 digital communication, it provides one analog retransmission output (0/4–20mA or 0–5/10V, programmable) and two relay outputs for alarm signaling or load control. Two dry contact switch inputs are also available for status monitoring.

The meter operates reliably in ambient temperatures from -10°C to +55°C, with storage tolerance from -25°C to +70°C. Relative humidity should not exceed 93% without corrosive gases, and the maximum installation altitude is 2500m.

Bize ulaşın, ihtiyaçlarınıza güç katalım.

30 yılı aşkın süredir odaklanmış bağlılık,
İlerlemeye güç katıyor, yaşamları güçlendiriyor.

Şimdi iletişime geçin