Premium Low Voltage Current Transformer Solutions

Verimliliği ve Güç Faktörünü En Üst Düzeye Çıkarın

Ürün Kategorisi

What Is A Low Voltage Current Transformer?

alçak geri̇li̇m akim transformatörü is a passive device used to reduce high primary currents to a standardized, lower secondary current for measurement or protection. It is designed for systems up to 1 kV AC, which covers most industrial distribution panels, commercial meter cabinets, and motor control centers. Unlike power transformers, a Low Voltage Current Transformer prioritizes accuracy and phase fidelity over power throughput. Typical secondary outputs are 5 A or 1 A, allowing standard meters and relays to operate safely without direct contact with high current lines. You often see them installed on busbars, cables, or windings inside low voltage switchgear.

Core Functions of a Low Voltage Current Transformer

FonksiyonDescriptionTypical Data / Range
Current MeasurementReduces primary line current to a safe secondary valuePrimary: 5 A up to 5000 A
Energy MeteringFeeds accurate current signals to kWh metersAccuracy Class: 0.2, 0.5, 1.0
Protection RelayingDrives overcurrent or earth fault relaysBurden: 2.5 VA – 30 VA
Electrical IsolationSeparates measuring instruments from high current circuitsInsulation level: 0.72/3 kV
Güç Kalitesi İzlemeSends waveform data for harmonic analysisFrequency: 50 Hz or 60 Hz

Teknik Özellikler Tablosu

This table helps engineers and procurement teams quickly match the low voltage current transformer to their system requirements.

ParametreTypical Value / RangeNotes
Rated Primary Current100 A to 3000 ALower values available on request
Rated Secondary Current5 A or 1 A1 A reduces line drop over long cables
Accuracy Class (Metering)0.2, 0.5, 1.00.2S / 0.5S for wide measuring range
Accuracy Class (Protection)5P10, 10P10, 5P20ALF (Accuracy Limit Factor)
Rated Burden (VA)1.5, 2.5, 5, 10, 15, 30Depends on core cross‑section
Short‑time Thermal Current20 × rated primary for 1 secondWithstands fault current
Rated Insulation Voltage0.72/3 kV (full wave)50/60 Hz dielectric test
Operating Frequency50 Hz / 60 HzSame unit works for both
Ambient Temperature Range–25°C to +55°CIndoor or outdoor enclosure options
Construction TypeWound primary / Bar primary / Split‑coreSplit‑core suited for retrofits

Endüstri Uygulamaları

Where Our Low Voltage Current Transformer Delivers Proven Results

A low voltage current transformer is not a one‑size‑fits‑all component either. Below are field scenarios where our low voltage current transformer improves measurement consistency, supports selective protection coordination, and delivers reliable current data for energy accounting — without interrupting the main conductor during installation.

Neden ZHIMING'in Alçak Gerilim Akım Transformatörünü Seçmelisiniz?

High accuracy under real load

Our low voltage current transformer maintains Class 0.2S accuracy from 1% to 120% of the rated primary current. Many standard units only perform well near full load, but ZHIMING devices give you reliable readings even when the line runs lightly loaded — for example, overnight or during seasonal low production.

Split‑core design saves significant downtime

The split‑core version of our low voltage current transformer opens around existing cables or busbars without disconnecting the primary conductor. You do not need to shut down a whole production line or pull a switchgear apart just to add a metering point.

Wide burden range from 1.5 VA up to 30 VA

Not every installation has the meter sitting right next to the transformer. With a ZHIMING low voltage current transformer, you can drive long cable runs to a central panel, or connect multiple instruments in series, without exceeding the rated burden.

One part number works for both 50 Hz and 60 Hz systems

Whether your plant operates on a 50 Hz grid in Europe or a 60 Hz grid in North America, the same ZHIMING low voltage current transformer covers both.

Higher saturation knee point prevents false protection trips

Some low voltage current transformers saturate too early when an electric motor starts or when a transformer energizes, causing the protection relay to see a distorted current waveform and trip unnecessarily.

Fast lead time for modified specifications

If your project needs a non‑standard primary current rating, a different window size, or a special secondary output, ZHIMING does not start from zero. We keep premade cores, enclosures, and terminals in stock, so a modification typically takes days instead of months.

Sorularınız mı var?
Cevaplarımız Var

Önde gelen bir güç kondansatörü üreticisi, 25 yılı aşkın deneyimiyle ürünle ilgili sorunlar, işle ilgili sorular veya hizmetle ilgili endişeler dahil olmak üzere tüm sorularınızı yanıtlamak için burada.

Hala Sorularınız mı Var? Yardım İçin Buradayız

Aradığınızı bulamadınız mı?

İstediğiniz Zaman Bize Ulaşın

8093446000

Yes, if your safety procedures allow it. ZHIMING split‑core models include a non‑magnetic latch and self‑closing mechanism. However, you must follow local lockout/tagout rules first.

Dangerous high voltage will appear at the secondary terminals. It can cause arcing, damage insulation, or injure personnel. Always short the secondary terminals before removing a connected meter.

Use 5 A when the distance to the meter is short (≤10 meters) and your meter accepts 5 A directly. Choose 1 A when the cable run exceeds 20 meters, or when you want to minimize burden losses.

Generally no. Metering cores saturate earlier to protect the meter; protection cores need to remain linear under fault currents. If you need both functions from one device, select a dual‑winding low voltage current transformer.

Yes. Above 55°C core losses change and ratio error increases. ZHIMING low voltage current transformers include temperature coefficients per IEC 61869‑2. For outdoor hot climates, choose a down‑rated primary current or a larger window size.

Bize ulaşın, ihtiyaçlarınıza güç katalım.

30 yılı aşkın süredir odaklanmış bağlılık,
İlerlemeye güç katıyor, yaşamları güçlendiriyor.

Şimdi iletişime geçin
Bu formu doldurmak için lütfen tarayıcınızda JavaScript'i etkinleştirin.

Şimdi Bize Ulaşın!

Bu formu doldurmak için lütfen tarayıcınızda JavaScript'i etkinleştirin.