ZMCF Serisi Otomatik Reaktif Güç Kompanzasyon Kondansatörü Harmonik Kontrol Cihazı
ZMCF Serisi Otomatik Reaktif Güç Kompanzasyon Kondansatörü Harmonik Kontrol Cihazı

ZMCF Serisi Otomatik Reaktif Güç Kompanzasyon Kondansatörü Harmonik Kontrol Cihazı

Model No: ZMCF Serisi
Reaktif Güç Otomatik Kompanzasyon Kontrolörü.
Minimum Sipariş: 100 adet
Stok Süresi :7-15Gün

What Is Capacitor Harmonic Controller?

The ZHIMING ZMCF Series Automatic Reactive Power Compensation Capacitor Controller is designed for use in low-voltage power distribution systems. It automatically regulates capacitor banks to maintain the power factor at a preset level, thereby improving transformer efficiency, reducing line losses, and enhancing voltage stability and power quality. Built around fundamental reactive power calculation and harmonic-immune measurement, the ZMCF delivers stable and accurate reactive power compensation in demanding electrical environments.

Code And Implication of the Capacitor Harmonic Controller

ZMFC(code)

Working Conditions of the Capacitor Harmonic Controller

Ürün Parametreleri

ÖğeŞartname
Rated Operating VoltageAC 220V
Rated Operating CurrentAC 0-5A
Rated Frequency Range45Hz-65Hz
Power Factor Display AccuracyGecikme 0.001 / Kurşun 0.001
Reactive Power Measurement Range0-9999 kVar
Active Power Measurement Range0-9999 kW
UnderVoltage Protection ThresholdAC 300V
Output Contact CapacityAC 220V / 7A
Current Detection Sensitivity≥ 20mA
Total Power Consumption≤ 10VA
Display TypeLCD
Protection DegreeIP40 (Muhafaza)

Main Technical Data of the Capacitor Harmonic Controller

Not: Diğer özel spesifikasyon modelleri kullanıcı gereksinimlerine göre tedarik edilir

ÖğeŞartname
Mounting TypePanel montajlı
Outline Dimensions (W × H × D)144 × 144 × 100 mm
Cut-out Size138 × 138 mm
AğırlıkYaklaşık 0,8 kg
Wiring ModeArka paneldeki terminal bloğu bağlantısı

Why Choose ZHIMING's Capacitor Harmonic Controller?

Fundamental Reactive Power Calculation for Stable Switching

The ZMCF calculates compensation capacity based on fundamental reactive power, preventing switching oscillation that plagues conventional power factor controllers. This approach ensures stable and precise capacitor bank regulation, protecting switching equipment from repeated inrush stress and extending the service life of the compensation system.

Harmonic-Immune Measurement with Real-Time THD Monitoring

Even in the presence of harmonics, the controller accurately displays the system power factor with high precision and a wide display range. It monitors total power factor (PF) in real time and simultaneously displays voltage and current total harmonic distortion (THD), giving operators complete visibility into power quality.

Comprehensive Voltage and Harmonic Protection

Built-in over-voltage and under-voltage protection safeguard the compensation system from abnormal grid conditions, while protection against excessive voltage harmonics prevents harmonic-induced equipment damage. Multi-level protection ensures reliable operation and reduces maintenance costs in fluctuating power environments.

Flexible Dual-Mode Operation with Permanent Data Retention

The ZMCF supports dual operation modes — Automatic and Manual — through a user-friendly human-machine interface with digital display of multiple control parameters for intuitive configuration. Non-volatile memory ensures data retention in the event of power failure, while low input impedance for the current signal (≤0.01Ω) enables accurate measurement with minimal signal loss.

SSS

What is the ZMCF Automatic Reactive Power Compensation Capacitor Controller used for?

The ZMCF is designed for low-voltage power distribution systems, where it automatically regulates capacitor banks to maintain the power factor at a preset level. This improves transformer efficiency, reduces line losses, and enhances voltage stability and power quality.

The controller calculates compensation capacity based on fundamental reactive power rather than total apparent power. This fundamental-based calculation prevents capacitor switching oscillation, ensuring stable and accurate regulation even in systems with significant harmonic content.

The ZMCF operates at a rated voltage of AC 220V and a rated current of AC 0–5A, with a rated frequency range of 45Hz–65Hz. Its total power consumption is ≤10VA, and it features a low current-signal input impedance of ≤0.01Ω.

The controller includes built-in over-voltage and under-voltage protection, as well as protection against excessive voltage harmonics. These safeguards protect both the controller and the connected capacitor banks from abnormal voltage conditions and harmonic-induced stress.

Yes. The Capacitor Harmonic Controller uses non-volatile memory, ensuring that all configured parameters are retained in the event of a power failure. No reconfiguration is required after power is restored, minimizing downtime in unattended installations. 

Bize ulaşın, ihtiyaçlarınıza güç katalım.

30 yılı aşkın süredir odaklanmış bağlılık,
İlerlemeye güç katıyor, yaşamları güçlendiriyor.

Şimdi iletişime geçin

Şimdi Bize Ulaşın!