Split-Phase Capacitor Controller
Split-Phase Capacitor Controller

Split-Phase Capacitor Controller

Model No: JKWF-12 Series
Reactive power auto-compensation controller.
Minimum Order: 100 pieces
Stock Time: 7-15 days

Uygulama

ZHIMING  brand of JKWF-12 Series Reactive Power Auto-compensation Controller.

1.1 Fully digital design with true AC sampling and a user-friendly human-machine interface featuring a large LCD display in English.

1.2 Modular structure with an optimized, professional appearance.

1.3 Real-time display of system parameters, including:
  – Power factor
  – Voltage
  – Current
  – Active power
  – Reactive power
  – Voltage total harmonic distortion (THD)
  – Current total harmonic distortion (THD)
  – System frequency (average)
  – Capacitor switching status (on/off)

1.4 Capacitor control modes:
  – Three-phase compensation
  – Comprehensive (balanced) compensation

1.5 Compensation modes:
  – Manual mode
  – Automatic mode

1.6 Reactive power factor is used as the control sampling value, with integrated harmonic detection and protection functions.

1.7 Equipped with an RS-485 communication interface and MODBUS protocol, enabling easy integration with intelligent power distribution cabinets.

Technical Specifications

Measurement Data

  • Voltage Measurement Range: 100V – 290V
  • Primary Current Measurement Range: 0 – 6000A
  • Secondary Current Sensitivity: ≥ 50mA
  • Power Factor Display Range: Lagging 0.200 ~ Leading 0.200
  • Operating Voltage: 220V ± 20%
  • Frequency Range: 47 – 53Hz
  • Active Power Measurement Range: 0 – 6553 kW
  • Reactive Power Measurement Range: 0 – 6553 kVar
  • Voltage Total Harmonic Distortion (THD): 0.0% – 100.0%
  • Current Total Harmonic Distortion (THD): 0.0% – 100.0%

Input / Output Signals

  • Voltage Sampling Inputs: L1, L2, L3 phases
  • Current Sampling Input: Bus current transformer (CT), secondary 0 – 5A
  • Control Output: Relay output

Communication Interface

  • Communication Port: RS-485
  • Protocol: MODBUS RTU
  • Baud Rate: 9600 bps

Settings and Adjustable Parameters

  • CT Ratio Setting (Primary/Secondary): 50 – 9999 (/5)
  • Input/Disconnection Delay Time: 1 – 240 seconds
  • Input Threshold Limit (cosφ): 0.7 ~ –0.7
  • Over-Voltage Protection Threshold: 220V – 260V
  • Under-Voltage Protection Threshold: 180V – 220V
  • Voltage Harmonic Protection Limit: 1% – 99%
    • Note: Setting at 99% disables protection
  • Current Harmonic Protection Limit: 1% – 99%
    • Note: Setting at 99% disables protection

Wiring Diagram

Bize ulaşın, ihtiyaçlarınıza güç katalım.

30 yılı aşkın süredir odaklanmış bağlılık,
İlerlemeye güç katıyor, yaşamları güçlendiriyor.

Şimdi iletişime geçin
Bu formu doldurmak için lütfen tarayıcınızda JavaScript'i etkinleştirin.