Split-Faz Kondansatör Kontrolörü
Split-Faz Kondansatör Kontrolörü

Split-Faz Kondansatör Kontrolörü

Model No: JKWF-12 Series
Reactive power auto-compensation controller.
Minimum Sipariş: 100 adet
Stok Süresi: 7-15 gün

Uygulama

ZHIMING  brand of JKWF-12 Series Reactive Power Auto-compensation Controller.

1.1 Fully digital design with true AC sampling and a user-friendly human-machine interface featuring a large LCD display in English.

1.2 Modular structure with an optimized, professional appearance.

1.3 Real-time display of system parameters, including:
  – Power factor
  – Voltage
  – Current
  – Active power
  – Reactive power
  – Voltage total harmonic distortion (THD)
  – Current total harmonic distortion (THD)
  – System frequency (average)
  – Capacitor switching status (on/off)

1.4 Capacitor control modes:
  – Three-phase compensation
  – Comprehensive (balanced) compensation

1.5 Compensation modes:
  – Manual mode
  – Automatic mode

1.6 Reactive power factor is used as the control sampling value, with integrated harmonic detection and protection functions.

1.7 Equipped with an RS-485 communication interface and MODBUS protocol, enabling easy integration with intelligent power distribution cabinets.

Teknik Özellikler

Measurement Data

  • Voltage Measurement Range: 100V – 290V
  • Primary Current Measurement Range: 0 – 6000A
  • Secondary Current Sensitivity: ≥ 50mA
  • Power Factor Display Range: Lagging 0.200 ~ Leading 0.200
  • Operating Voltage: 220V ± 20%
  • Frequency Range: 47 – 53Hz
  • Aktif Güç Ölçüm Aralığı: 0 – 6553 kW
  • Reaktif Güç Ölçüm Aralığı: 0 – 6553 kVar
  • Voltage Total Harmonic Distortion (THD): 0.0% – 100.0%
  • Current Total Harmonic Distortion (THD): 0.0% – 100.0%

Input / Output Signals

  • Voltage Sampling Inputs: L1, L2, L3 phases
  • Current Sampling Input: Bus current transformer (CT), secondary 0 – 5A
  • Control Output: Relay output

İletişim Arayüzü

  • Communication Port: RS-485
  • Protocol: MODBUS RTU
  • Baud Rate: 9600 bps

Settings and Adjustable Parameters

  • CT Ratio Setting (Primary/Secondary): 50 – 9999 (/5)
  • Input/Disconnection Delay Time: 1 – 240 seconds
  • Input Threshold Limit (cosφ): 0.7 ~ –0.7
  • Over-Voltage Protection Threshold: 220V – 260V
  • Düşük Voltaj Koruma Eşiği: 180V – 220V
  • Voltage Harmonic Protection Limit: 1% – 99%
    • Note: Setting at 99% disables protection
  • Current Harmonic Protection Limit: 1% – 99%
    • Note: Setting at 99% disables protection