Wielofunkcyjny miernik mocy do monitorowania i sterowania
Wielofunkcyjny miernik mocy do monitorowania i sterowania

Wielofunkcyjny miernik mocy do monitorowania i sterowania

Model No: ZM-3D Series
The Multifunction Power Meter is designed for accurate measurement, monitoring, and analysis of electrical parameters in power systems. It provides real-time readings of voltage, current, active/reactive power, power factor, energy consumption, frequency, and harmonic content, with communication interfaces for integration into automation systems.
Minimalne zamówienie: 100 szt.
Czas magazynowania: 7-15 dni

Kod i implikacje

12.jpg

Zastosowanie

ZHIMING  brand of multi-functional monitoring and control meter is a high-performance intelligent instrument designed for real-time measurement and monitoring of power parameters and harmonics. It provides the following key functions:

  • Real-time measurement of voltage, current, active power, reactive power, apparent power, power factor, and frequency
  • Measurement of forward and reverse active/reactive energy
  • Time-sharing and fixed-time energy metering
  • Harmonic analysis (up to the 31st order for voltage and current)
  • Real-time waveform display and power quality analysis
  • Event logging and demand recording

The device includes multiple I/O interfaces for field-level monitoring and control, and is equipped with an RS-485 communication port supporting integration with intelligent power distribution systems and energy management platforms. This meter offers a high performance-to-price ratio and can fully replace traditional power transmitters, energy meters, and associated measurement instruments. It is widely used in:

  • Energy management systems
  • Power monitoring systems
  • Industrial enterprises
  • Public utilities
  • Smart buildings
  • Intelligent switchgear systems

Standardy zgodności

  • GB/T 22264.1-2008 – Mounted digital display electrical measuring instruments – Part 1: Definitions and general requirements
  • GB/T 22264.7-2008 – Part 7: Special requirements for multi-functional meters
  • GB/T 22264.8-2008 – Part 8: Recommended test methods
  • GB/T 17215.322-2008 – AC static active energy meters (Class 0.2S and 0.5S)
  • GB/T 17215.323-2008 – AC static reactive energy meters (Class 2 and 3)
  • Multi-functional energy meters
  • Electrical fire protection detector
  • Code for Fire Protection Design of Tall Civil Buildings
  • Code for Low Voltage Distribution Design
  • Code for Residential Building Design
  • Installation and Operation of Residual Current Devices (RCDs)
  • Code for Building Fire Protection Design

Specyfikacja techniczna

Dokładność pomiaru

  • Voltage: Class 0.5
  • Current: Class 0.5
  • Active Power: Class 0.5
  • Reactive Power: Class 0.5
  • Frequency: ±0.02 Hz
  • Active Energy: Class 0.5S or 0.2S
  • Reactive Energy: Class 1 or 2
  • Power Factor: ±0.5%

Auxiliary Power Supply

  • Operating Voltage: AC/DC 80V ~ 270V
  • Power Consumption: <4VA

Communication & I/O

  • RS-485 Interface: 1 channel, Modbus-RTU protocol
    • Baud rate: 1200 ~ 9600bps (default: 2400bps)
  • Digital Inputs: 4 dry contact inputs
  • Relay Outputs: 3 outputs (AC 250V/5A, DC 30V/5A)
  • Analog Outputs: 3 channels (0/420mA or 05/10V)
  • Energy Pulse Outputs: 2 channels
    • Pulse constant: 8000 imp/kWh (or kvarh)

Warunki środowiskowe

  • Operating Temperature: -10℃ ~ +55℃
  • Storage Temperature: -25℃ ~ +70℃
  • Relative Humidity: ≤93% (non-condensing, no corrosive gases)
  • Altitude: ≤2500m

Signal Input

  • Wiring Mode: Three-phase four-wire / three-phase three-wire
  • Rated Voltage: AC 57.7V, 100V, 220V, 380V
  • Rated Current: AC 1A or 5A
  • Overload Capacity:
    • Voltage: 1.2x (continuous), 2x/1s (instantaneous)
    • Current: 1.2x (continuous), 10x/5s (instantaneous)
  • Power Consumption:
    • Voltage: <1VA per phase
    • Current: <0.4VA per phase
  • Input Impedance:
    • Voltage: >300kΩ
    • Current: <20mΩ
  • Frequency Range: 45 ~ 65Hz

Electrical Safety

  • Insulation Resistance: >100MΩ
  • Dielectric Strength: AC 2kV (1 min)

Electromagnetic Compatibility (EMC)

  • Electrostatic Discharge (ESD): IEC Level 4
  • Electrical Fast Transients (EFT): IEC Level 4
  • Surge Immunity: IEC Level 4

Rozmiar produktu

Specyfikacja i wymiary

12.jpg
MeasurementsHarmonic AnalysisCommunication InterfacesAlarm OutputsReverse power
Three-phase voltage and currentSupports Total Harmonic Distortion (THD) measurementModbus RTU / Modbus TCPOvervoltage / undervoltageHarmonic limit exceedance
Active, reactive, and apparent powerMulti-order harmonic measurementsRS485Overcurrent / undercurrentOther user-definable alarm conditions
Współczynnik mocyEthernet
CzęstotliwośćRS232 (optional, per configuration)
Import/export energy (forward and reverse energy)
DisplayRecording FunctionsAccuracy ClassMontażPower SupplyZgodność z normami
LCD or color backlit screenEvent logging (faults, alarms, operations)Class 0.2S or 0.5S (selectable/model-dependent)DIN-rail mountingAC or DC power input (specify voltage range)IEC 62053 series (accuracy and metering standards)
Configurable display pages for parameters, trends, and alarmsData logging (interval or triggered)Panel mountingIEC 61000 series (EMC, immunity/emission)
Energy consumption trend curves or profilesOther relevant industry standards as required
Other user-definable alarm conditions

Skontaktuj się z nami, zaspokoimy Twoje potrzeby.