Dławik wyjściowy falownika
Dławik wyjściowy falownika

Dławik wyjściowy falownika

Model No: OCL Series
This product adopted high-quality foreign silicone steel sheet and copper wire being processed by use of advanced technology, with such features as small size, low temperature rise, no noise and etc..
Minimalne zamówienie: 100 szt.
Stock Time:7-15Days

The ZHIMING OCL Series Inverter Output Reactor is an electrical component installed between a variable frequency drive (VFD) and the motor it controls. Built with high-quality imported silicon steel laminations and high-purity copper windings, this Inverter Output Reactor suppresses the steep voltage rise rate (dV/dt) of PWM output waveforms and limits capacitive charging currents in long motor cables. By smoothing the inverter output waveform, it improves power quality, boosts the system power factor, and protects motor windings from insulation stress. Compact, quiet, and thermally efficient, the OCL Series complies with IEC 289:1987 and is suitable for a wide range of industrial drive applications.

Parametry produktu

ParametrSpecyfikacja
Rated Operating Voltage380V / 50Hz
Voltage Drop1%–2%
Electric StrengthIron core–winding: 3000VAC / 50Hz / 10mA / 60s, no arcing, no breakdown
Insulation ResistanceIron core–winding: 1000VDC, ≥100MΩ
Noise Level<35dB (measured 1m horizontally from reactor)
Temperature Rise<60K

Main Technical Data of the Inverter Output Reactor

Dławik wyjściowy falownika

Note: The below-mentioned data is the reference for typical models; we can design and produce according to the special requirements of the user. We reserve the right to change the technical data.

ModelPower Adapter (kW)Rated Current (A)Voltage DropInsulation GradeWymiary (mm)Mounting (mm)Otwór
OCL-80.75 (1.5)82%, 1%F, H140×100×12075×556
OCL-102.2102%, 1%F, H140×100×12075×556
OCL-102.5 (4.0)102%, 1%F, H140×100×12075×556
OCL-155.5152%, 1%F, H140×100×12075×556
OCL-207.5202%, 1%F, H140×100×12075×556
OCL-3011302%, 1%F, H170×130×14580×656
OCL-4015402%, 1%F, H170×130×14580×656
OCL-5018502%, 1%F, H170×130×14580×6510
OCL-6022602%, 1%F, H210×130×170110×6510
OCL-8030802%, 1%F, H210×130×170110×6510
OCL-110371102%, 1%F, H210×130×170110×6510
OCL-120451202%, 1%F, H210×150×170110×8510
OCL-150551502%, 1%F, H210×160×215110×9510
OCL-200752002%, 1%F, H210×160×215110×9510
OCL-250902502%, 1%F, H210×160×215110×9510
OCL-2801102802%, 1%F, H250×180×260133×11010
OCL-3001323002%, 1%F, H250×180×260133×11010
OCL-4001604002%, 1%F, H280×190×260170×11510
OCL-4501874502%, 1%F, H280×190×260170×11510
OCL-5002005002%, 1%F, H280×190×260170×11510
OCL-6002506002%, 1%F, H280×210×260170×13512
OCL-8003158002%, 1%F, H320×230×290200×12012
OCL-100040010002%, 1%F, H320×260×290200×13012
OCL-110045011002%, 1%F, H350×260×320200×13012

Why Choose ZHIMING's Inverter Output Reactor?

Premium Core & Winding Materials

The OCL Series Inverter Output Reactor uses high-grade grain-oriented silicon steel laminations and high-purity oxygen-free copper conductors, achieving excellent magnetic performance with minimal core losses. This material selection directly translates to lower heat generation and higher energy efficiency across the entire operating range.

Low-Noise, Low-Temperature-Rise Operation

Engineered with core clamping techniques, precision winding tensioning, and vacuum pressure impregnation (VPI), this Inverter Output Reactor operates at less than 35dB — exceptionally quiet for industrial environments. Temperature rise stays under 60K thanks to an optimized thermal design that maximizes heat dissipation through core geometry and ventilation.

Superior Insulation & Dielectric Strength

Class F/H insulation materials combined with VPI processing provide outstanding dielectric endurance. The Inverter Output Reactor withstands 3000VAC between core and winding with insulation resistance exceeding 100MΩ at 1000VDC, ensuring long-term reliability even under the high dV/dt stress of modern IGBT-based drives.

Flexible Sizing & Compact Footprint

With 24 standard models spanning 0.75kW to 450kW motor power, the OCL Series covers virtually all common industrial drive applications. Each unit is designed for space-efficient panel mounting with standardized fixing points, anti-corrosion finishes, and accessible copper terminals for secure low-resistance connections.

FAQ

What does an Inverter Output Reactor do in a VFD system?

The OCL Series Inverter Output Reactor is installed between the VFD and the motor to limit the voltage rise rate (dV/dt) of PWM output pulses and reduce capacitive charging currents in long motor cables. This protects motor insulation from premature aging, reduces electromagnetic interference, and improves overall power quality.

The OCL Series spans 24 models covering motor adapters from 0.75kW to 450kW, with rated currents from 8A to 1100A. Custom designs beyond this range can be produced upon request.

The OCL Series is designed for low acoustic noise emission, measuring less than 35dB at a distance of 1 meter horizontally from the reactor. This is achieved through core clamping, precision winding tensioning, and full vacuum pressure impregnation.

The Inverter Output Reactor features Class F or H insulation and passes a 3000VAC / 50Hz / 60s dielectric test between core and winding without arcing or breakdown. Insulation resistance exceeds 100MΩ when tested at 1000VDC.

Yes. The data table represents typical models, but ZHIMING can design and produce OCL reactors to meet special requirements including non-standard current ratings, voltage ratings, mounting dimensions, and environmental conditions. Contact the manufacturer with your specifications for a customized solution.

Skontaktuj się z nami, zaspokoimy Twoje potrzeby.

Ponad 30 lat skoncentrowanego zaangażowania,
Napędzamy postęp, wzmacniamy życie.

Kontakt teraz

Skontaktuj się z nami już teraz!