Zhiming Group fokus pada komponen tegangan tinggi dan rendah serta peralatan lengkap. Kebutuhan Anda adalah titik awal, dan kami merancang dan menyesuaikan produksi untuk memastikan bahwa setiap peralatan dibuat untuk memenuhi kebutuhan daya Anda.
Memaksimalkan Efisiensi & Faktor Daya
A Power Capacitor is a passive electrical component that stores and releases electrical energy in AC circuits. Unlike batteries (which store DC energy), a power capacitor is designed to react rapidly to voltage changes, providing or absorbing reactive power to stabilize voltage and improve the power factor of an electrical system.
In industrial and commercial facilities, low power factor (e.g., 0.6–0.75) is mainly caused by inductive loads such as motors, transformers, and lighting ballasts. This leads to higher utility penalties, overheating of cables, and reduced system capacity. A power factor correction capacitor works by supplying leading reactive power locally, cancelling out the lagging reactive power drawn by inductive equipment. As a result, the total apparent power (kVA) decreases for the same real power (kW), lowering electricity bills and freeing up transformer capacity.
| Fungsi | Deskripsi |
|---|---|
| Koreksi Faktor Daya | Meningkatkan PF dari 0,6-0,8 menjadi ≥0,95, menghilangkan biaya penalti. |
| Stabilisasi Tegangan | Mengurangi penurunan tegangan selama penyalaan beban berat. |
| Penyaringan Harmonik (dengan reaktor yang diredam) | Melindungi peralatan dari distorsi arus. |
| Penghematan Energi | Menurunkan kerugian I²R pada kabel dan transformator sebesar 10-20%. |
This table helps engineers and procurement teams quickly match the right low voltage power capacitor or high voltage power capacitor to their system requirements.
| Parameter | Seri Tegangan Rendah (≤1kV) | Seri Tegangan Tinggi (1kV - 35kV) |
|---|---|---|
| Tegangan Pengenal | 230V, 400V, 690V, 1100V | 3.3kV, 6.6kV, 11kV, 33kV |
| Rentang Kapasitas | 1 - 100 kvar | 50 - 2000 kvar |
| Rugi Dielektrik (tan δ) | ≤0,15 W / kvar | ≤0,20 W / kvar |
| Kapasitas Kelebihan Beban | 1,5 × arus pengenal (kontinu) | 1,3 × arus pengenal (kontinu) |
| Resistensi Pelepasan | Built-in, debit ke ≤50V dalam 1 menit | External, ≤75V in 5 min |
| Standar | IEC 60831, UL 810, CE | IEC 60871, CE, ISO9001 |
| Seumur Hidup Khas | 120.000 jam | 150.000 jam |
| Note: All units feature self-healing technology, overpressure separation protection, and dry or semi-dry biodegradable fillers. | ||
Where Our Power Factor Correction Capacitor Delivers Proven Results
A power factor correction capacitor is not a one-size-fits-all device. Below are typical scenarios where our power capacitor reduces reactive energy penalties, improves voltage stability, and lowers harmonic distortion.
Our power capacitor uses high-grade polypropylene film with low loss and self-healing technology. Micro-breakdowns are instantly isolated, preventing catastrophic failure and extending service life to over 120,000 hours.
Each low voltage power capacitor features a patented internal overpressure disconnector. If internal pressure rises abnormally, the unit safely disconnects from the circuit – no explosion, no fire, no oil leakage.
Every power factor correction capacitor is subjected to a 72-hour burn-in at 1.2× rated voltage before shipment. Capacitance tolerance, dielectric loss, and thermal stability are individually recorded and traceable.
From 230V to 35kV, we manufacture both low voltage power capacitor and high voltage power capacitor with non‑standard ratings. MOQ flexible for OEM projects – your specifications, our fast turnaround.
ISO9001, CE, IEC 60831/60871, and National High-Tech Enterprise Certificate. Our power capacitor series is trusted by utilities and industrial plants in over 40 countries.
We stand behind our products. Extended warranty up to 8 years available. Our engineers provide free sizing assistance, harmonic analysis, and on-site troubleshooting – before and after the sale.
Produsen kapasitor daya terkemuka dengan pengalaman lebih dari 25 tahun siap menjawab semua pertanyaan Anda-meliputi masalah terkait produk, pertanyaan bisnis, atau masalah terkait layanan.
Masih Ada Pertanyaan? Kami Siap Membantu
Tidak menemukan yang Anda cari?
Hubungi Kami Kapan Saja
A low voltage power capacitor is designed for systems ≤1kV (e.g., 400V industrial panels), while a high voltage power capacitor operates at 1kV to 35kV, typically used in utility substations or large MV motor compensation. Their internal dielectric, terminal insulation, and discharge resistors differ accordingly.
You need three pieces of data:
Average power factor (from utility bill)
Target power factor (usually 0.95–0.98)
Monthly active energy (kWh) and reactive energy (kVARh)
Use the formula: Required kVAR = Active Power (kW) × (tanφ₁ – tanφ₂). Or simply send us 30 days of load data – we will calculate it for free.
Standard capacitors may overheat under harmonics. You need a detuned power factor correction capacitor with a series reactor (typically 7% or 14%). Our harmonic‑rated series is marked “HD” and includes over‑temperature protection.
Our power capacitor units are designed for 120,000–150,000 hours (over 15 years) at rated voltage and ≤45°C ambient. End‑of‑life signs include capacitance loss >10% or visible bulging – we offer free capacitance testing kits for bulk orders.
Yes. Custom voltages (e.g., 480V, 525V, 690V) and non‑standard kVAR steps are available with a minimum order quantity. Contact us with your specification sheet for a fast quotation.
Hubungi kami, kami memenuhi kebutuhan Anda.
Komitmen terfokus selama lebih dari 30 tahun,
Mendorong kemajuan, memberdayakan kehidupan.