What Is High Voltage Start Shunt Electrical Reactor?

A High Voltage Start Shunt Electrical Reactor (QKSG/QKSC series) is a dry-core reactor designed to limit inrush current when starting high-voltage motors in 6kV and 10kV systems. It utilizes premium imported silicon steel laminations with uniformly segmented columns and multiple epoxy-insulated air gaps, bonded by high-temperature structural adhesive to maintain gap stability during operation. The encapsulated coil windings are vacuum-impregnated with high-temperature insulating varnish, delivering exceptional dielectric properties, high mechanical integrity, and resistance to cracking under motor starting inrush currents and thermal shocks.

Code And Implication of the High Voltage Start Shunt Electrical Reactor

high voltage reactor(code)

Working Conditions of the High Voltage Start Shunt Electrical Reactor

Paramètres du produit

Type Capacité de démarrage Tension nominale Dimension
L x L x H
Puissance du moteur entraîné
QKSG-220 393  6kV,10kV 760x400x835    220 
QKSG-250 445  760x400x835    250 
QKSG-280 493  760x400x835    280 
QKSG-315 553  805x450x875    315 
QKSG-355 620  805x450x875    355 
QKSG-400 700  805x450x875    400 
QKSG-450 787  865x450x920    450 
QKSG-500 854  865x450x920    500 
QKSG-560 963  865x450x920    560 
QKSG-630 1081  865x450x920    630 
QKSG-710 1215  865x450x920    710 
QKSG-800 1366  895x450x960    800 
QKSG-900 1538  895x450x960    900 
QKSG-1000 1844  895x450x960    1000 
QKSG-1120 2040  955x450x1015    1120 
QKSG-1250 2273  955x450x1015    1250 
QKSG-1400 2543  955x450x1015    1400 

Remarque : D'autres modèles aux spécifications particulières sont fournis en fonction des besoins de l'utilisateur.

Schéma de câblage

high voltage reactor(diagram)

Main Technical Data of the High Voltage Start Shunt Electrical Reactor

ObjetSpécifications
Tension nominale6 kV / 10 kV
Insulation / Temperature ClassF grade (155°C)
Noise Level≤ 65 dB (not exceeding national standard)
LossLower than oil-immersed reactors
StructureDry-core, compact, lightweight, small footprint, simple structure, easy installation

Why Choose ZHIMING's High Voltage Start Shunt Electrical Reactor?

Premium Silicon Steel Core with Stable Epoxy Air Gaps

The High Voltage Start Shunt Electrical Reactor core uses imported silicon steel laminations with uniformly segmented columns and multiple epoxy-insulated air gaps, bonded by high-temperature structural adhesive. This construction maintains gap stability during operation while reducing operational noise and enhancing corrosion resistance for long-term reliability under repeated starts.

Dry-Core Design: Compact, Lightweight & Low Loss

The dry-core start reactor is smaller and lighter than traditional oil-immersed and air-core reactors, offering a simple structure, small footprint, and easy installation. Its loss is lower than that of oil-immersed reactors, reducing energy waste during motor starting and lowering total life-cycle operating cost.

Class F Thermal Rating (155°C) for Demanding Starts

Temperature resistance reaches F grade (155°C), allowing the reactor to withstand the thermal stress of repeated high-voltage motor starts. Combined with encapsulated winding technology, it delivers high mechanical integrity and resistance to cracking under inrush currents and thermal shocks, ensuring dependable performance in heavy industrial duty.

Low-Noise Encapsulated Winding Construction

Coils employ encapsulated winding technology with primary insulation vacuum-impregnated with high-temperature insulating varnish. This process yields exceptional dielectric properties and noise not exceeding the national standard (65 dB), making the reactor suitable for noise-sensitive installations while ensuring superior insulation performance.

FAQ

What is a High Voltage Start Shunt Electrical Reactor used for?

The High Voltage Start Shunt Electrical Reactor limits inrush current when starting high-voltage motors in 6kV and 10kV systems. By connecting in series with the motor during start-up, it suppresses the starting current surge, protecting the motor and upstream switchgear from excessive current stress.

The QKSG/QKSC dry-core starter reactor is smaller and lighter than traditional oil-immersed and air-core reactors, with a simpler structure, smaller footprint, and easier installation. It also features lower loss than oil-immersed reactors and eliminates oil handling and leakage concerns, making it safer and more environmentally friendly.

The reactor’s temperature resistance level reaches F grade (155°C). This thermal rating, combined with encapsulated winding and vacuum-impregnated high-temperature insulating varnish, allows it to withstand the heat generated by repeated motor starting cycles without insulation degradation.

The QKSG series covers driven motor power from 220 kW to 1400 kW, with 17 standard models (QKSG-220 through QKSG-1400). Each model corresponds to a specific start capacity and physical dimension, allowing engineers to match the reactor precisely to the motor’s starting requirements.

Yes. While the standard range covers 220–1400 kW motors at 6kV and 10kV, other special specification models are supplied according to user requirements. Custom start capacities, non-standard voltages, and special environmental adaptations can be provided on request. 