What Is A Panel Display Meter?

A Panel Display Meter is a digital instrument mounted on an electrical panel or switchgear door to measure and display one or more electrical parameters — such as voltage, current, frequency, power, or power factor. Unlike analog gauges or simple digital voltmeters, a Panel Display Meter often includes true RMS sampling, programmable alarms, and communication ports (RS485 / Modbus). It serves as the operator’s real‑time window into the health of low‑ or medium‑voltage circuits.

Core Functions of a Panel Display Meter

FonctionTypical Data / Performance
Parameter measurementVoltage (L‑N / L‑L), current (per phase), frequency, active/reactive power, power factor
True RMS samplingYes, up to 15th or 31st harmonic
Classe de précisionVoltage/current: ±0.5% of reading; Power: ±1.0%
Display typeLED (red/green) or LCD with backlight
Update rate0.5 – 2 seconds (adjustable)
Overload withstand2× rated voltage continuous; 20× rated current for 1 second

Types of Panel Display Meters We Offer

Compteur numérique à combinaison de tension et de courant

Compteur de courant/tension

Mesureur de tension triphasé numérique

Compteur multifonction

Tableau des spécifications techniques

This table helps engineers and procurement teams quickly match the right panel display meter to their system requirements.

ParamètresCommon Value Range
Input voltage range (direct connection)0 – 600V AC (L‑N)
Input current (via CT secondary)1A or 5A AC
Alimentation auxiliaireAC 85–265V or DC 24V, 48V, 110V, 220V
Display digits4‑digit or 3‑line multi‑function
CommunicationRS485 (Modbus RTU), optional Ethernet / Profibus
Digital inputs2 – 4 programmable (dry contact)
Digital outputs2 – 3 relay outputs (normally open)
Température de fonctionnement-10°C to +60°C
Panel cutout size96×96 mm, 72×72 mm, or 48×96 mm (common)

Applications industrielles

Where a Panel Display Meter Proves Its Real Value
A good panel display meter is not a one‑size‑fits‑all readout. Below are typical situations where our panel display meter catches hidden drift in voltage, flags imbalanced currents before breakers trip, and gives maintenance crews a clear second‑by‑second view of load changes.

Why Choose ZHIMING's Panel Display Meter?

True RMS sampling on all three phases

Keeps readings accurate even under strong harmonic distortion. While cheaper meters can misread by 10% or more with VFD loads, this Panel Display Meter stays within ±0.5% error across 3‑phase unbalanced systems.

Programmable high/low alarms with relay outputs

Lets the meter act as a simple controller, not just a display. You can set over‑voltage or under‑current thresholds directly on the Panel Display Meter and connect its relays to a buzzer or shunt trip – no PLC needed.

Universal auxiliary power (AC/DC 80–265V)

Eliminates voltage compatibility headaches in retrofit panels. Electricians often install this Panel Display Meter without swapping the existing control transformer, because it accepts anything from 110V AC to 220V DC.

Built‑in RS485 Modbus RTU as standard

Makes energy monitoring and data logging straightforward. Instead of buying an extra communication module, every Panel Display Meter comes ready to talk to SCADA or a cloud gateway, saving panel space and cost.

Compact 96×96 mm form factor with deep menu lock

Fits standard cutouts and prevents unauthorised changes. Once the configuration is set, a parameter lock on the Panel Display Meter keeps operators from accidentally resetting CT ratios or alarm setpoints.

Logs min/max values with time stamp

Simplifies troubleshooting of intermittent faults. When a mysterious voltage dip occurs only once a week, the Panel Display Meter’s internal memory shows the exact value and time of the event, cutting analysis time dramatically.

Vous avez des questions ?
Nous avons des réponses

L'un des principaux fabricants de condensateurs de puissance, fort de plus de 25 ans d'expérience, est là pour répondre à toutes vos questions, qu'il s'agisse de problèmes liés aux produits, de questions commerciales ou de problèmes de service.

Vous avez encore des questions ? Nous sommes là pour vous aider

Vous n'avez pas trouvé ce que vous cherchiez ?

Contactez-nous à tout moment

8093446000

Yes. A single 3‑phase Panel Display Meter typically shows voltage (L‑L and L‑N), current per phase, frequency, power, and power factor, replacing three or four analog meters.

Average‑responding meters are accurate only for pure sine waves. A true RMS Panel Display Meter is essential when your load includes VFDs, rectifiers, or LED lighting – otherwise you may see readings 20‑30% lower than the actual value.

For primary current above 5A or 10A, yes. This Panel Display Meter accepts standard 1A or 5A CT secondary inputs. For low‑current circuits (<5A), direct connection may be possible – check the specification sheet.

Yes. ZHIMING offers auxiliary power versions from 24V DC up to 220V DC, including 48V DC. Just order the correct model code or use the universal AC/DC supply that covers 80‑265V AC/DC.

Enter the programming menu (protected by a password), navigate to “system setup”, and key in your primary CT value (e.g., 600A for 600/5A CT). The Panel Display Meter automatically scales the current reading – no external scaling resistors needed.

Contactez-nous, nous sommes à l'écoute de vos besoins.

Plus de 30 ans d'engagement ciblé,
Favoriser le progrès, améliorer les conditions de vie.

Contact
Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.

Contactez-nous dès maintenant !

Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.