Numéro de modèle Série JKWD
Contrôleur de compensation automatique de la puissance réactive.
Commande minimale : 100 pièces
Délai de stockage : 7-15 jours

What Is Power Compensation Controller?

The ZHIMING JKWD Series JKW Reactive Power Compensation Controller is an intelligent auto-compensation device designed for self-regulating capacitor banks in low-voltage distribution systems. Based on full digital AC sampling technology, this Reactive Power Compensation Controller uses reactive power as the primary controlling physical quantity to achieve high-precision power factor correction. It enhances power transformer operating efficiency, reduces line losses, and improves voltage regulation — ultimately increasing ROI and grid reliability. With support for 1 to 12 output loops, dual manual/automatic working modes, and comprehensive digital display of power factor, reactive power, voltage, and current (primary side), the JKW Controller provides a complete solution for power quality management in industrial and commercial electrical networks.

Code And Implication of the Power Compensation Controller

JKW Reactive Power Compensation Controller(code)

Working Conditions of the JKW Reactive Power Compensation Controller

Paramètres du produit

ParamètresSpécifications
Tension nominaleAC 380V +10% (IEC 60038)
Courant nominalAC 0–5A (max. continuous)
Fréquence nominale50Hz ±5%
Paramètres de contrôle
Sensibilité100mA (courant de fonctionnement min.)
Target PF Setting0.70–0.99 (adjustable, 0.01 resolution; factory default: 0.98)
Switching DelayTransient mode: 0.5ms–200s; Steady-state mode: 2–200s
CT Ratio Range50:5 à 3000:5 (résolution 1:1 ; valeur par défaut : 500:5)
Output CapacityTransient: DC 12V @ 50mA/channel; Steady-state: 380V AC @ 7A/channel or 200V AC @ 5A/channel
Précision de la mesure
VoltageClasse 1.0 (±1,0% de la lecture)
CurrentClasse 1.0 (±1,0% de la lecture)
Facteur de puissance±1,0%
Reactive PowerClasse 2.0 (±2,0% de la lecture)
JKW Reactive Power Compensation Controller(diagram)

Taille du produit

Dimensions de la découpe du panneau

Modèle de contrôleurDimensions de la découpe (H × L)ToléranceNotes de montage
JKWD5-16138,0 × 138,0 mm±0,5 mmDécoupe carrée avec rayon ≤0,5 mm aux angles
JKWD5113,0 × 113,0 mm±0,5 mmÉpaisseur max. du panneau : 3,0 mm

Exigences critiques en matière d'installation :

1.Surface Flatness: ≤0.5 mm across cutout area
2. Finition des bords : sans bavure (Ra 6,3 μm max.)
3. Espace libre : ≥20 mm derrière le panneau pour la terminaison du câblage.
4. Joint d'étanchéité : Appliquer un joint IP54 (inclus) en cas d'utilisation dans des environnements pollués.

Engineering Drawing Notation:

JKWD5-16         
  Ø4.3×4 M4      
  Trous de montage  
  (typique) 

Fig. 1 : Découpe standard avec positions de fixation M4 (toutes les dimensions en mm)

Why Choose ZHIMING's Power Compensation Controller?

Full Digital Control & High-Precision PF Regulation

The JKW Reactive Power Compensation Controller adopts AC sampling technology with digital integration and filtration, making it insensitive to harmonic interference. Using reactive power as the primary controlling physical quantity, it achieves high-precision automatic power factor correction with adjustable target PF from 0.70 to 0.99.

Intelligent Switching Optimization & Extended System Life

An optimized automatic control scheme minimizes unnecessary capacitor switching cycles — reducing contactor wear and extending the service life of the entire compensation system. Built-in over-voltage and under-voltage judgment with fast cutoff protects capacitor banks from abnormal voltage conditions, while the configurable 200-second re-insertion delay ensures complete capacitor discharge before reconnection.

Strong Anti-Interference & Data Protection

Capable of withstanding up to 2000V interference pulses from the direct power supply, this Reactive Power Compensation Controller maintains stable operation without crashing or losing data. All control parameters are stored in non-volatile memory, ensuring data integrity even during power failures.

Flexible Configuration & User-Friendly Operation

Equipped with both manual and automatic working modes, the controller supports easy on-site commissioning and debugging. The digital display provides real-time readout of power factor, reactive power, voltage, and current (primary side), while the current sampling input resistance below 0.05Ω allows direct connection from measuring loops without additional signal conditioning.

FAQ

What is the main purpose of this Reactive Power Compensation Controller?

The JKW Reactive Power Compensation Controller automatically regulates capacitor banks in low-voltage distribution systems to maintain the target power factor. By minimizing reactive power drawn from the grid, it improves transformer efficiency, reduces line losses, and lowers electricity costs while enhancing overall voltage stability.

The JKWD Series supports 1 to 12 output loops, configurable based on the compensation system size. Each loop can operate in either transient mode (DC 12V @ 50mA) or steady-state mode (AC 380V @ 7A / AC 220V @ 5A), accommodating various contactor and thyristor switching configurations.

Yes. The target power factor is programmable from 0.70 to 0.99 with 0.01 resolution (factory default: 0.98). All control parameters — including CT ratio (50:5 to 3000:5), switching delay, and sensitivity — are fully adjustable via the digital interface and retained in non-volatile memory after power-off.

The controller continuously monitors voltage and automatically executes fast cutoff of capacitor banks when over-voltage or under-voltage is detected, preventing capacitor damage. The built-in re-insertion delay (configurable up to 200 seconds per capacitor group) ensures complete discharge before reconnection, reducing inrush current impact on the electrical network.

The AC sampling and digital integration technology makes the controller insensitive to harmonic distortion, ensuring accurate reactive power measurement even in electrically noisy environments. Combined with the <0.05Ω current sampling input resistance, it delivers reliable Class 1.0 voltage/current accuracy and ±1.0% power factor precision without requiring external signal conditioners.

Contactez-nous, nous sommes à l'écoute de vos besoins.

Plus de 30 ans d'engagement ciblé,
Favoriser le progrès, améliorer les conditions de vie.

Contact
Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.

Contactez-nous dès maintenant !

Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.