مقياس طاقة متعدد الوظائف للمراقبة والتحكم متعدد الوظائف
مقياس طاقة متعدد الوظائف للمراقبة والتحكم متعدد الوظائف

مقياس طاقة متعدد الوظائف للمراقبة والتحكم متعدد الوظائف

Model No: ZM-3D Series
The Multifunction Power Meter is designed for accurate measurement, monitoring, and analysis of electrical parameters in power systems. It provides real-time readings of voltage, current, active/reactive power, power factor, energy consumption, frequency, and harmonic content, with communication interfaces for integration into automation systems.
الحد الأدنى للطلب 100 قطعة
وقت المخزون: 7-15 يومًا

القانون والآثار المترتبة

12.jpg

التطبيق

زهيمنج  brand of multi-functional monitoring and control meter is a high-performance intelligent instrument designed for real-time measurement and monitoring of power parameters and harmonics. It provides the following key functions:

  • Real-time measurement of voltage, current, active power, reactive power, apparent power, power factor, and frequency
  • Measurement of forward and reverse active/reactive energy
  • Time-sharing and fixed-time energy metering
  • Harmonic analysis (up to the 31st order for voltage and current)
  • Real-time waveform display and power quality analysis
  • Event logging and demand recording

The device includes multiple I/O interfaces for field-level monitoring and control, and is equipped with an RS-485 communication port supporting integration with intelligent power distribution systems and energy management platforms. This meter offers a high performance-to-price ratio and can fully replace traditional power transmitters, energy meters, and associated measurement instruments. It is widely used in:

  • Energy management systems
  • Power monitoring systems
  • Industrial enterprises
  • Public utilities
  • Smart buildings
  • Intelligent switchgear systems

معايير الامتثال

  • GB/T 22264.1-2008 - أدوات القياس الكهربائية المثبتة على شاشات رقمية - الجزء 1: التعاريف والمتطلبات العامة
  • GB/T 22264.7-2008 - الجزء 7: المتطلبات الخاصة للعدادات متعددة الوظائف
  • GB/T 22264.8-2008 - الجزء 8: طرق الاختبار الموصى بها
  • GB/T 17215.322.322-2008 - عدادات الطاقة النشطة الثابتة بالتيار المتردد (الفئة 0.2S و0.5S)
  • GB/T 17215.323-2008 - عدادات الطاقة التفاعلية الساكنة بالتيار المتردد (الفئة 2 و3)
  • عدادات الطاقة متعددة الوظائف
  • كاشف كهربائي للحماية من الحرائق
  • كود تصميم الحماية من الحرائق للمباني المدنية الشاهقة
  • كود تصميم توزيع الجهد المنخفض
  • كود تصميم المباني السكنية
  • تركيب أجهزة التيار المتبقي وتشغيلها (RCDs)
  • كود تصميم الحماية من حرائق المباني

المواصفات الفنية

دقة القياس

  • Voltage: Class 0.5
  • Current: Class 0.5
  • Active Power: Class 0.5
  • Reactive Power: Class 0.5
  • Frequency: ±0.02 Hz
  • Active Energy: Class 0.5S or 0.2S
  • Reactive Energy: Class 1 or 2
  • Power Factor: ±0.5%

Auxiliary Power Supply

  • Operating Voltage: AC/DC 80V ~ 270V
  • Power Consumption: <4VA

Communication & I/O

  • RS-485 Interface: 1 channel, Modbus-RTU protocol
    • Baud rate: 1200 ~ 9600bps (default: 2400bps)
  • Digital Inputs: 4 dry contact inputs
  • Relay Outputs: 3 outputs (AC 250V/5A, DC 30V/5A)
  • Analog Outputs: 3 channels (0/420mA or 05/10V)
  • Energy Pulse Outputs: 2 channels
    • Pulse constant: 8000 imp/kWh (or kvarh)

الظروف البيئية

  • Operating Temperature: -10℃ ~ +55℃
  • Storage Temperature: -25℃ ~ +70℃
  • Relative Humidity: ≤93% (non-condensing, no corrosive gases)
  • Altitude: ≤2500m

Signal Input

  • Wiring Mode: Three-phase four-wire / three-phase three-wire
  • Rated Voltage: AC 57.7V, 100V, 220V, 380V
  • Rated Current: AC 1A or 5A
  • Overload Capacity:
    • Voltage: 1.2x (continuous), 2x/1s (instantaneous)
    • Current: 1.2x (continuous), 10x/5s (instantaneous)
  • Power Consumption:
    • Voltage: <1VA per phase
    • Current: <0.4VA per phase
  • Input Impedance:
    • Voltage: >300kΩ
    • Current: <20mΩ
  • Frequency Range: 45 ~ 65Hz

Electrical Safety

  • Insulation Resistance: >100MΩ
  • Dielectric Strength: AC 2kV (1 min)

Electromagnetic Compatibility (EMC)

  • Electrostatic Discharge (ESD): IEC Level 4
  • Electrical Fast Transients (EFT): IEC Level 4
  • Surge Immunity: IEC Level 4

حجم المنتج

المواصفات والأبعاد

12.jpg
Measurementsالتحليل التوافقيCommunication InterfacesAlarm OutputsReverse power
Three-phase voltage and currentSupports Total Harmonic Distortion (THD) measurementModbus RTU / Modbus TCPOvervoltage / undervoltageHarmonic limit exceedance
Active, reactive, and apparent powerMulti-order harmonic measurementsRS485Overcurrent / undercurrentOther user-definable alarm conditions
Power factorEthernet
الترددRS232 (optional, per configuration)
Import/export energy (forward and reverse energy)
DisplayRecording FunctionsAccuracy ClassMountingPower SupplyStandards Compliance
LCD or color backlit screenEvent logging (faults, alarms, operations)Class 0.2S or 0.5S (selectable/model-dependent)DIN-rail mountingAC or DC power input (specify voltage range)IEC 62053 series (accuracy and metering standards)
Configurable display pages for parameters, trends, and alarmsData logging (interval or triggered)Panel mountingIEC 61000 series (EMC, immunity/emission)
Energy consumption trend curves or profilesOther relevant industry standards as required
Other user-definable alarm conditions

اتصل بنا، فنحن ندعم احتياجاتك.

أكثر من 30 عاماً من الالتزام المركّز,
تعزيز التقدم وتمكين الحياة.

اتصل بنا الآن