وحدة التحكم التلقائي في تعويض الطاقة التفاعلية
وحدة التحكم التلقائي في تعويض الطاقة التفاعلية

وحدة التحكم التلقائي في تعويض الطاقة التفاعلية

Model No: JKL/JKG Series
وحدة التحكم في الطاقة التفاعلية التلقائي للتعويض التلقائي.
الحد الأدنى للطلب 100 قطعة
وقت المخزون: 7-15 يومًا

زهيمنج  brand of Automatic Reactive Power Compensation Controller. This series of controllers employs a high-performance single-chip microcomputer as its hardware foundation. It fully utilizes the computer’s high-speed operational capabilities and logical judgment to achieve true digital intelligence. With advanced technology, comprehensive functionality, robust EMC performance, reliable operation, precise branch compensation, and a streamlined design, these controllers are the preferred solution for capacitive screen manufacturing.

Working Conditions of the Reactive Power Compensation Controller

المعلمة التقنية

المعلمةالمواصفات
طاقة التشغيلتيار متردد 220 فولت ±20% (50/60 هرتز)
الفولتية المقدرةتيار متردد 380 فولت/220 فولت (قابل للتخصيص)
دوائر التعويضات6/8/10/10/12/14/16 المخرجات (قابلة للتكوين)
قنوات التحكم6/8/10/10/12/14/16 قنوات
وقت الاستجابة≤20 مللي ثانية (نموذجي)
عبء أخذ العينات<0.05Ω (Current loop)
قوة العزل الكهربائي≥2500 فولت تيار متردد (1 دقيقة، عزل المدخلات عن المخرجات)
مقاومة العزل≥100 م (500 فولت تيار مستمر)
درجة الحرارة المحيطةالتشغيل: -25 درجة مئوية تحت الصفر إلى +65 درجة مئوية
التخزين: -40 درجة مئوية إلى +85 درجة مئوية
الرطوبة النسبية≤95% RH (بدون تكاثف)
الارتفاع≤2500م أ.س.س.ل.
تصنيف الحمايةIP40 (اللوحة الأمامية)
IP20 (القسم الطرفي)

Structure Features of the Reactive Power Compensation Controller

لماذا تختار وحدة التحكم في تعويض الطاقة التفاعلية من ZHIMING؟

Core Smart Tech

This Reactive Power Compensation Controller is built on a high-performance single-chip microcomputer. It adopts true RMS AC sampling and digital integration filtering for high-speed operation and precise judgment.

Strong EMC Stability

The Reactive Power Compensation Controller resists 2000V surge pulses (per IEC 61000-4-5). It ensures crash-free operation, data retention, and stable performance in harsh power environments.

Full Auto Calibration

No manual CT ratio configuration needed for this Reactive Power Compensation Controller. It auto-adapts to capacitor bank sizes and grid parameters, reducing commissioning workload.

Easy Operation & Protection

This Reactive Power Compensation Controller has manual/automatic dual modes. It features intuitive HMI and over-voltage protection, simplifying use and safeguarding capacitor banks.

Precise & Low-Burden

The Reactive Power Compensation Controller enables precise branch compensation. With input resistance <0.05Ω, it connects directly to CT secondary circuits without external shunts.

الأسئلة الشائعة

What’s the core hardware of Reactive Power Compensation Controller?
It uses a high-performance single-chip microcomputer as the hardware foundation, supporting high-speed operations and logical judgment for digital intelligence.
No. The Reactive Power Compensation Controller has automatic phase sequence detection and correction functions, avoiding manual adjustment errors.
It’s the preferred solution for capacitive screen manufacturing, and also applicable to various scenarios requiring reactive power compensation with high stability demands.
It digitally displays key grid parameters (power factor, over-voltage, current, control settings) via a direct-view digital interface for real-time monitoring.
Yes. Its streamlined design, dual operating modes, and automatic calibration simplify installation, commissioning, and testing processes.

اتصل بنا، فنحن ندعم احتياجاتك.

أكثر من 30 عاماً من الالتزام المركّز,
تعزيز التقدم وتمكين الحياة.

اتصل بنا الآن
يرجى تفعيل JavaScript في متصفحك لإكمال هذا النموذج.

اتصل بنا الآن!

يرجى تفعيل JavaScript في متصفحك لإكمال هذا النموذج.