{"id":229,"date":"2025-10-09T09:04:46","date_gmt":"2025-10-09T01:04:46","guid":{"rendered":"https:\/\/mediumslateblue-chimpanzee-835813.hostingersite.com\/?post_type=product&#038;p=229"},"modified":"2025-12-22T11:56:42","modified_gmt":"2025-12-22T03:56:42","slug":"digital-single-phase-voltage-meter","status":"publish","type":"product","link":"https:\/\/zmgs-global.com\/tr\/product\/digital-single-phase-voltage-meter","title":{"rendered":"Digital Single-phase Voltage Meter"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0130\u00e7indekiler<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/zmgs-global.com\/tr\/product\/digital-single-phase-voltage-meter\/#Code_and_Implication\" >Code and Implication<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/zmgs-global.com\/tr\/product\/digital-single-phase-voltage-meter\/#Application\" >Uygulama<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/zmgs-global.com\/tr\/product\/digital-single-phase-voltage-meter\/#Compliance_Standards\" >Compliance Standards<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/zmgs-global.com\/tr\/product\/digital-single-phase-voltage-meter\/#Technical_Specifications\" >Technical Specifications<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/zmgs-global.com\/tr\/product\/digital-single-phase-voltage-meter\/#Specification_Dimensions\" >Specification &amp; Dimensions<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Code_and_Implication\"><\/span><strong>Code and Implication<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image is-resized\"><img decoding=\"async\" src=\"https:\/\/www.zmgs-global.com\/static\/upload\/image\/20250327\/1743055131196031.jpg\" alt=\"12.jpg\" style=\"width:641px;height:auto\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Application\"><\/span><strong>Uygulama<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>ZHIMING&nbsp;&nbsp;<\/strong>brand of&nbsp;ZM-V, DV Series Digital Single-phase Voltage Meter\uff1b<\/p>\n\n\n\n<p>1. High-precision measurement of single-phase AC or DC voltage<br>2. Digital display with local data query function<br>3. Programmable voltage ratio<br>4. Supports RS-485 communication using Modbus-RTU protocol<br>5. Supports switch input\/output and analog signal output<br>6. Auxiliary power supply: AC\/DC 80V\u2013270V or AC 220V<br>7. Available in various form factors to meet different cabinet layout requirements<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Compliance_Standards\"><\/span><strong>Compliance Standards<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>GB\/T 22264.1-2008 \u2013 Mounted digital display electrical measuring instruments <\/li>\n\n\n\n<li>GB\/T 22264.7-2008 \u2013 Part 7: Special requirements for multi-functional meters<\/li>\n\n\n\n<li>GB\/T 22264.8-2008 \u2013 Part 8: Recommended test methods<\/li>\n\n\n\n<li>GB\/T 17215.322-2008 \u2013 AC static active energy meters (Class 0.2S and 0.5S)<\/li>\n\n\n\n<li>GB\/T 17215.323-2008 \u2013 AC static reactive energy meters (Class 2 and 3)<\/li>\n\n\n\n<li>Multi-functional energy meters<\/li>\n\n\n\n<li>Electrical fire protection detector<\/li>\n\n\n\n<li>Code for Fire Protection Design of Tall Civil Buildings<\/li>\n\n\n\n<li>Code for Low Voltage Distribution Design<\/li>\n\n\n\n<li>Code for Residential Building Design<\/li>\n\n\n\n<li>Installation and Operation of Residual Current Devices (RCDs)<\/li>\n\n\n\n<li>Code for Building Fire Protection Design<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Technical_Specifications\"><\/span><strong>Technical Specifications<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>Accuracy of measurement<\/strong><\/p>\n\n\n\n<p>Voltage: class 0.5<\/p>\n\n\n\n<p><strong>Auxiliary power supply<\/strong><\/p>\n\n\n\n<p>Working Voltage: AC\/DC 80V~270V, AC220V<\/p>\n\n\n\n<p>Power consumption: &lt;4VA<\/p>\n\n\n\n<p><strong>Function module<\/strong><\/p>\n\n\n\n<p>Communication interface: 1 way RS-485 communication, Modbus-RTU protocol<\/p>\n\n\n\n<p>baud rate:1200~9600bps, the default 2400bps<\/p>\n\n\n\n<p>Switch input: support 2 step node input<\/p>\n\n\n\n<p>Switch output: support 2 relay outputs, capacity: AC 250V\/5A, DC 30V\/5A<\/p>\n\n\n\n<p>Transmission output: support 1 analog output: 0\/4~20mAor 0~5\/10V<\/p>\n\n\n\n<p><strong>Environment<\/strong><\/p>\n\n\n\n<p>Working temperature: -10\u2103~+55\u2103<\/p>\n\n\n\n<p>Storage temperature: -25\u2103~+70\u2103<\/p>\n\n\n\n<p>Relative humidity is less than 93%, no corrosive gas<\/p>\n\n\n\n<p>Altitude: 2500m<\/p>\n\n\n\n<p><strong>Safety<\/strong><\/p>\n\n\n\n<p>Insulation resistance&gt;100M\u03a9<\/p>\n\n\n\n<p>AC withstand voltage AC 2KV<\/p>\n\n\n\n<p><strong>Electromagnetic compatibility<\/strong><\/p>\n\n\n\n<p>ESD: Class 4<\/p>\n\n\n\n<p>Electrical fast transient burst: Class 4<\/p>\n\n\n\n<p>Surge(impact): Class 4<\/p>\n\n\n\n<p><strong>Signal input<\/strong><\/p>\n\n\n\n<p>Connection mode: Single phase<\/p>\n\n\n\n<p>Rated voltage : AC 57.7V AC 100V AC 220V AC380V<\/p>\n\n\n\n<p>DC 2V DC20V DC200V DC600V<\/p>\n\n\n\n<p>Overload: 1.2 times(Continued), 2 times\/second (instantaneous)<\/p>\n\n\n\n<p>Power : &lt;1VA\/phase<\/p>\n\n\n\n<p>Impedance : &gt;300K\u03a9<\/p>\n\n\n\n<p>Frequency: 45~65Hz<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Specification_Dimensions\"><\/span><strong>Specification &amp; Dimensions<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image is-resized\"><img decoding=\"async\" src=\"https:\/\/yunpan.cdn.site.joinf.com\/5594599774213081\/dWQbtK8yZ4.png\" alt=\"\" style=\"width:391px;height:auto\"\/><\/figure>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"Code and Implication Application ZHIMING&nbsp;&nbsp;brand of&nbsp;ZM-V, DV Series Digital Single-phase Voltage Meter\uff1b 1. High-precision measurement of single-phase AC or DC voltage2. Digital display with local data query function3. Programmable voltage ratio4. Supports RS-485 communication using Modbus-RTU protocol5. Supports switch input\/output and analog signal output6. Auxiliary power supply: AC\/DC 80V\u2013270V or AC 220V7. Available in various [&hellip;]","protected":false},"featured_media":263,"menu_order":0,"template":"","meta":[],"products":[23],"class_list":["post-229","product","type-product","status-publish","has-post-thumbnail","hentry","products-current-voltage-meter"],"acf":[],"_links":{"self":[{"href":"https:\/\/zmgs-global.com\/tr\/wp-json\/wp\/v2\/product\/229","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zmgs-global.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zmgs-global.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/zmgs-global.com\/tr\/wp-json\/wp\/v2\/product\/229\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/tr\/wp-json\/wp\/v2\/media\/263"}],"wp:attachment":[{"href":"https:\/\/zmgs-global.com\/tr\/wp-json\/wp\/v2\/media?parent=229"}],"wp:term":[{"taxonomy":"products","embeddable":true,"href":"https:\/\/zmgs-global.com\/tr\/wp-json\/wp\/v2\/products?post=229"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}