{"id":220,"date":"2025-10-08T08:56:53","date_gmt":"2025-10-08T00:56:53","guid":{"rendered":"https:\/\/mediumslateblue-chimpanzee-835813.hostingersite.com\/?post_type=product&#038;p=220"},"modified":"2025-12-22T15:26:25","modified_gmt":"2025-12-22T07:26:25","slug":"jkw-reactive-power-compensation-controller","status":"publish","type":"product","link":"https:\/\/zmgs-global.com\/pl\/product\/jkw-reactive-power-compensation-controller","title":{"rendered":"Kontroler kompensacji mocy biernej JKW"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Spis tre\u015bci<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/zmgs-global.com\/pl\/product\/jkw-reactive-power-compensation-controller\/#Code_and_Implication\" >Kod i implikacje<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/zmgs-global.com\/pl\/product\/jkw-reactive-power-compensation-controller\/#Application\" >Zastosowanie<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/zmgs-global.com\/pl\/product\/jkw-reactive-power-compensation-controller\/#Structure_Features\" >Cechy struktury<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/zmgs-global.com\/pl\/product\/jkw-reactive-power-compensation-controller\/#Technical_Parameter\" >Parametry techniczne<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/zmgs-global.com\/pl\/product\/jkw-reactive-power-compensation-controller\/#Product_Size\" >Rozmiar produktu<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/zmgs-global.com\/pl\/product\/jkw-reactive-power-compensation-controller\/#Wiring_Diagram\" >Schemat po\u0142\u0105cze\u0144<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Code_and_Implication\"><\/span><strong>Kod i implikacje<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.zmgs-global.com\/static\/upload\/image\/20250327\/1743062338627369.jpg\" alt=\"12.jpg\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Application\"><\/span><strong>Zastosowanie<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>ZHIMING&nbsp;&nbsp;<\/strong>Kontroler kompensacji mocy biernej marki JKW jest przeznaczony do samoregulacji baterii kondensator\u00f3w w systemach dystrybucji niskiego napi\u0119cia. Zwi\u0119ksza on wydajno\u015b\u0107 operacyjn\u0105 transformatora mocy, redukuje straty linii i poprawia regulacj\u0119 napi\u0119cia - ostatecznie zwi\u0119kszaj\u0105c zwrot z inwestycji i niezawodno\u015b\u0107 sieci dzi\u0119ki zoptymalizowanej korekcji wsp\u00f3\u0142czynnika mocy.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Structure_Features\"><\/span><strong>Cechy struktury<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Przyj\u0119cie technologii pr\u00f3bkowania AC.<br>Integracja cyfrowa, filtracja, brak wra\u017cliwo\u015bci na fal\u0119 harmoniczn\u0105.<br>Je\u015bli chodzi o moc biern\u0105 jako kontroluj\u0105c\u0105 wielko\u015b\u0107 fizyczn\u0105, ma ona wysok\u0105 precyzj\u0119 sterowania.<br>Obs\u0142uga w pe\u0142ni cyfrowego parametru kontrolnego, \u0142atwa w u\u017cyciu, umieszczana we w\u0142a\u015bciwym miejscu w jednym kroku, a dane nie s\u0105 tracone w przypadku awarii zasilania.<br>Automatyczne przyj\u0119cie i optymalizacja doskona\u0142ego schematu sterowania, zmniejszenie liczby wej\u015b\u0107 i odci\u0119\u0107 oraz poprawa \u017cywotno\u015bci systemu.<br>Silna zdolno\u015b\u0107 przeciwzak\u0142\u00f3ceniowa mo\u017ce wytrzyma\u0107 impuls zak\u0142\u00f3caj\u0105cy 2000 V z bezpo\u015bredniego zasilania i nie ulega awarii, nie traci danych i jest w stanie pracowa\u0107 stabilnie.<br>Cyfrowy wy\u015bwietlacz wsp\u00f3\u0142czynnik\u00f3w mocy sieci elektrycznej, mocy biernej, napi\u0119cia, pr\u0105du (strona pierwotna) i parametr\u00f3w sterowania.<br>Dwa tryby pracy: r\u0119czny i automatyczny s\u0105 wygodne dla u\u017cytkownika podczas instalacji i debugowania.<br>Z funkcj\u0105 oceny przepi\u0119cia, podnapi\u0119cia oraz wy\u015bwietlania i szybkiego wy\u0142\u0105czania grupy kondensator\u00f3w, zapobiega pracy grupy kondensator\u00f3w w warunkach przepi\u0119cia.<br>Z funkcj\u0105 dost\u0119pnego wej\u015bcia i odci\u0119cia szokowania i blokowania.<br>Funkcja op\u00f3\u017anienia czasu wybranej pojedynczej grupy kondensator\u00f3w przez 200 sekund od wej\u015bcia odci\u0119cia, co sprawia, \u017ce kondensator ma obfity czas roz\u0142adowania po odci\u0119ciu i zmniejsza wp\u0142yw na sie\u0107 elektryczn\u0105 po ponownym u\u017cyciu.<br>Rezystancja wej\u015bciowa sygna\u0142u pr\u00f3bkowania pr\u0105du jest mniejsza ni\u017c 0,05\u03a9; mo\u017cna j\u0105 bezpo\u015brednio usun\u0105\u0107 z p\u0119tli pomiarowej.<br>P\u0119tle wyj\u015bciowe 1-12 P\u0119tla.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Technical_Parameter\"><\/span>Parametry techniczne<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">Parametr<\/td><td>Specyfikacja<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Napi\u0119cie znamionowe<\/strong><\/td><td>AC 380V +10% (IEC 60038)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Pr\u0105d znamionowy<\/strong><\/td><td>AC 0-5A (maks. ci\u0105g\u0142y)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Cz\u0119stotliwo\u015b\u0107 znamionowa<\/strong><\/td><td>50Hz \u00b15%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Parametry kontrolne<\/strong><\/td><td><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u25b6 Czu\u0142o\u015b\u0107<\/td><td>100 mA (min. pr\u0105d roboczy)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Docelowe ustawienie PF<\/td><td>0,70-0,99 (regulowany, rozdzielczo\u015b\u0107 0,01; domy\u015blne ustawienie fabryczne: 0,98)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\">Op\u00f3\u017anienie prze\u0142\u0105czania<\/td><td>Tryb przej\u015bciowy: 0,5ms-200s<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Tryb stanu ustalonego: 2-200 s<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Zakres wsp\u00f3\u0142czynnika CT<\/td><td>50:5 do 3000:5 (rozdzielczo\u015b\u0107 1:1; domy\u015blne ustawienie fabryczne: 500:5)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\">Wydajno\u015b\u0107 wyj\u015bciowa<\/td><td>Przej\u015bciowe: DC 12V @ 50mA\/kana\u0142<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Stan ustalony: 380V AC @ 7A\/kana\u0142 lub 200V AC @ 5A\/kana\u0142<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>Dok\u0142adno\u015b\u0107 pomiaru<\/strong><\/td><td><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Napi\u0119cie<\/td><td>Klasa 1.0 (\u00b11,0% odczytu)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u25b6 Pr\u0105d<\/td><td>Klasa 1.0 (\u00b11,0% odczytu)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Wsp\u00f3\u0142czynnik mocy<\/td><td>\u00b11,0%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Moc bierna<\/td><td>Klasa 2.0 (\u00b12,0% odczytu)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Product_Size\"><\/span>Rozmiar produktu<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>Wymiary wyci\u0119cia w panelu<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Model kontrolera<\/strong><\/td><td><strong>Wymiary wyci\u0119cia (wys. \u00d7 szer.)<\/strong><\/td><td><strong>Tolerancja<\/strong><\/td><td><strong>Uwagi dotycz\u0105ce monta\u017cu<\/strong><\/td><\/tr><tr><td>JKWD5-16<\/td><td>138,0 \u00d7 138,0 mm<\/td><td>\u00b10,5 mm<\/td><td>Kwadratowe wyci\u0119cie o promieniu \u22640,5 mm na rogach<\/td><\/tr><tr><td>JKWD5<\/td><td>113,0 \u00d7 113,0 mm<\/td><td>\u00b10,5 mm<\/td><td>Maks. grubo\u015b\u0107 panelu: 3,0 mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Krytyczne wymagania instalacyjne:<\/strong><br>1. P\u0142asko\u015b\u0107 powierzchni: \u22640,5 mm w ca\u0142ym obszarze wyci\u0119cia<br>2. Wyko\u0144czenie kraw\u0119dzi: bez zadzior\u00f3w (maks. Ra 6,3 \u03bcm)<br>3. Odst\u0119p: \u226520 mm za panelem na zako\u0144czenie okablowania<br>4. Uszczelnienie: Zastosowa\u0107 uszczelk\u0119 IP54 (w zestawie) w przypadku u\u017cytkowania w zanieczyszczonym \u015brodowisku<\/p>\n\n\n\n<p><strong>Notacja rysunku technicznego<\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>&nbsp; JKWD5-16&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>&nbsp; \u00d84,3\u00d74 M4&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>&nbsp; Otwory monta\u017cowe&nbsp;&nbsp;<br>&nbsp; (typowy)&nbsp;&nbsp;&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><em>Rys. 1: Standardowe wyci\u0119cie z pozycjami mocowania M4 (wszystkie wymiary w mm)<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wiring_Diagram\"><\/span>Schemat po\u0142\u0105cze\u0144<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.zmgs-global.com\/static\/upload\/image\/20250611\/1749606848118755.png\" alt=\"image.png\" title=\"1749606848118755.png\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/www.zmgs-global.com\/static\/upload\/image\/20250611\/1749606912161617.png\" alt=\"image.png\" title=\"1749606912161617.png\"\/><\/figure>","protected":false},"excerpt":{"rendered":"Code and Implication Application ZHIMING&nbsp;&nbsp;brand of JKW Reactive Power Compensation Controller is designed for self-regulating capacitor banks in low-voltage distribution systems. It enhances power transformer operating efficiency, reduces line losses, and improves voltage regulation \u2013 ultimately increasing ROI and grid reliability through optimized power factor correction. Structure Features \u25cf Adopt AC sampling technology.\u25cfDigital integration, filtration, [&hellip;]","protected":false},"featured_media":280,"menu_order":0,"template":"","meta":[],"products":[16],"class_list":["post-220","product","type-product","status-publish","has-post-thumbnail","hentry","products-three-phase-capacitor-controller"],"acf":[],"_links":{"self":[{"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/product\/220","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/product\/220\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/media\/280"}],"wp:attachment":[{"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/media?parent=220"}],"wp:term":[{"taxonomy":"products","embeddable":true,"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/products?post=220"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}