{"id":2513,"date":"2026-04-15T14:59:52","date_gmt":"2026-04-15T06:59:52","guid":{"rendered":"https:\/\/zmgs-global.com\/?p=2513"},"modified":"2026-04-21T15:00:06","modified_gmt":"2026-04-21T07:00:06","slug":"how-does-the-power-factor-correction-work","status":"publish","type":"post","link":"https:\/\/zmgs-global.com\/pl\/how-does-the-power-factor-correction-work.html","title":{"rendered":"Jak dzia\u0142a korekcja wsp\u00f3\u0142czynnika mocy?"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"2513\" class=\"elementor elementor-2513\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e5042f7 e-flex e-con-boxed e-con e-parent\" data-id=\"e5042f7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6ae67b1 elementor-widget elementor-widget-text-editor\" data-id=\"6ae67b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"3\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Power factor is one of those electrical concepts that sounds more complicated than it actually is. At its core, it\u2019s about how efficiently electrical power is being used. When the power factor is low, a lot of current is flowing through the system without doing any real work \u2014 just bouncing back and forth between the source and the load.<\/span><\/p><\/div><\/div><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"4\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">That\u2019s where <a href=\"https:\/\/zmgs-global.com\/products\/reactive-power-compensation-controller\"><strong>power factor correction<\/strong><\/a> comes in. It\u2019s not magic, but the way it works is pretty clever. By adding the right equipment in the right places, reactive power can be supplied locally instead of being drawn from the utility. The result? Lower current, reduced losses, and often a smaller electricity bill.<\/span><\/p><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d4704b elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"7d4704b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2026\/03\/Split-Phase-Capacitor-Controller.webp\" class=\"attachment-full size-full wp-image-2315\" alt=\"Capacitor Controller\" srcset=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2026\/03\/Split-Phase-Capacitor-Controller.webp 800w, https:\/\/zmgs-global.com\/wp-content\/uploads\/2026\/03\/Split-Phase-Capacitor-Controller-150x150.webp 150w, https:\/\/zmgs-global.com\/wp-content\/uploads\/2026\/03\/Split-Phase-Capacitor-Controller-768x768.webp 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-98d6436 elementor-widget elementor-widget-heading\" data-id=\"98d6436\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/zmgs-global.com\/pl\/how-does-the-power-factor-correction-work.html\/#The_Basic_Principle_Behind_Power_Factor_Correction\" >The Basic Principle Behind Power Factor Correction<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/zmgs-global.com\/pl\/how-does-the-power-factor-correction-work.html\/#How_Power_Factor_Correction_Equipment_Functions\" >How Power Factor Correction Equipment Functions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/zmgs-global.com\/pl\/how-does-the-power-factor-correction-work.html\/#Step-by-Step_How_Power_Factor_Correction_Works_in_Practice\" >Step-by-Step: How Power Factor Correction Works in Practice<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/zmgs-global.com\/pl\/how-does-the-power-factor-correction-work.html\/#The_Physics_of_Reactive_Power_Compensation\" >The Physics of Reactive Power Compensation<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/zmgs-global.com\/pl\/how-does-the-power-factor-correction-work.html\/#Practical_Considerations_in_How_Power_Factor_Correction_Works\" >Practical Considerations in How Power Factor Correction Works<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/zmgs-global.com\/pl\/how-does-the-power-factor-correction-work.html\/#FAQ\" >FAQ<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"The_Basic_Principle_Behind_Power_Factor_Correction\"><\/span>The Basic Principle Behind Power Factor Correction<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d54dc1 elementor-widget elementor-widget-text-editor\" data-id=\"3d54dc1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"6\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">To understand how power factor correction works, it helps to think about what\u2019s happening in an electrical system with inductive loads. Motors, transformers, and similar equipment need two types of power:<\/span><\/p><\/div><\/div><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"7\" data-node-type=\"list\"><div class=\"node-content\" data-v-37d25bc6=\"\"><ul class=\"list-node list-disc\" data-v-79057d57=\"\" data-v-37d25bc6=\"\"><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Active power (measured in kW) \u2014 does the actual work<\/span><\/p><\/div><\/div><\/div><\/li><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Reactive power (measured in kVAR) \u2014 creates magnetic fields but doesn\u2019t perform useful work<\/span><\/p><\/div><\/div><\/div><\/li><\/ul><\/div><\/div><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"8\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">The power factor is essentially the ratio of active power to total apparent power. When it\u2019s low, the system is drawing more current than necessary to deliver the same amount of useful work.<\/span><\/p><\/div><\/div><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"9\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Correction works by introducing capacitive reactive power to offset the inductive reactive power. Capacitors and inductors have opposite effects on the phase relationship between voltage and current. When balanced properly, they cancel each other out, bringing the power factor closer to unity.<\/span><\/p><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2043c1 elementor-widget elementor-widget-heading\" data-id=\"a2043c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"How_Power_Factor_Correction_Equipment_Functions\"><\/span>How Power Factor Correction Equipment Functions<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49073bb elementor-widget elementor-widget-text-editor\" data-id=\"49073bb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>The most common approach involves capacitor banks. These are connected in parallel with the load, either at the main distribution board or closer to individual pieces of equipment.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b76eb5 elementor-widget elementor-widget-heading\" data-id=\"6b76eb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">The Role of Capacitors<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4da6ac3 elementor-widget elementor-widget-text-editor\" data-id=\"4da6ac3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"13\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Capacitors store and release electrical energy in a way that\u2019s opposite to inductors. While an inductive load causes current to lag behind voltage, a capacitor causes current to lead. By introducing capacitive reactance into the system, the lagging current from inductive loads gets compensated.<\/span><\/p><\/div><\/div><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"14\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">It\u2019s a bit like balancing a seesaw. Too much inductive load tips it one way; adding capacitance tips it back toward equilibrium.<\/span><\/p><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-227a127 elementor-widget elementor-widget-heading\" data-id=\"227a127\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Fixed Versus Automatic Correction<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ca7564 elementor-widget elementor-widget-text-editor\" data-id=\"6ca7564\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"16\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Fixed capacitor banks provide a constant amount of reactive power compensation. They work fine when the load is steady, but they don\u2019t adjust if demand changes throughout the day.<\/span><\/p><\/div><\/div><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"17\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Automatic power factor correction panels solve this by switching capacitor stages on and off based on real-time measurements. A controller monitors the power factor continuously and engages or disengages capacitor steps as needed. This keeps the correction matched to the actual load, avoiding both under-correction and over-correction.<\/span><\/p><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-198ea96 e-flex e-con-boxed e-con e-parent\" data-id=\"198ea96\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fac9c2e elementor-widget elementor-widget-heading\" data-id=\"fac9c2e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Step-by-Step_How_Power_Factor_Correction_Works_in_Practice\"><\/span>Step-by-Step: How Power Factor Correction Works in Practice<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3f7ea14 elementor-widget elementor-widget-text-editor\" data-id=\"3f7ea14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"19\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Here\u2019s what happens when power factor correction is applied to a typical industrial facility:<\/span><\/p><\/div><\/div><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"20\" data-node-type=\"list\"><div class=\"node-content\" data-v-37d25bc6=\"\"><ol class=\"list-node list-decimal\" data-v-79057d57=\"\" data-v-37d25bc6=\"\"><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" value=\"1\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">The system initially operates with a low power factor (say, 0.75) due to inductive loads like motors<\/span><\/p><\/div><\/div><\/div><\/li><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" value=\"2\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Capacitor banks are installed at the main switchboard or distribution panels<\/span><\/p><\/div><\/div><\/div><\/li><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" value=\"3\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">The capacitors supply reactive power locally, reducing the amount drawn from the utility<\/span><\/p><\/div><\/div><\/div><\/li><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" value=\"4\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Total current flowing through the supply cables decreases<\/span><\/p><\/div><\/div><\/div><\/li><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" value=\"5\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Power factor improves (typically to 0.95 or higher)<\/span><\/p><\/div><\/div><\/div><\/li><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" value=\"6\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Voltage drop across the distribution system is reduced<\/span><\/p><\/div><\/div><\/div><\/li><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" value=\"7\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Losses in cables and transformers decrease<\/span><\/p><\/div><\/div><\/div><\/li><\/ol><\/div><\/div><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"21\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">The utility meter still records the same active power consumption (the actual work being done hasn\u2019t changed), but the reactive power demand drops significantly. In regions where utilities charge for reactive power or penalize low power factor, this translates directly into cost savings.<\/span><\/p><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53f8e0a elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"53f8e0a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/07\/Three-Phase-Low-Voltage-Shunt-Power-Capacitor-e1765777152302.webp\" class=\"attachment-full size-full wp-image-155\" alt=\"Three Phase Low Voltage Power Capacitor\" srcset=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/07\/Three-Phase-Low-Voltage-Shunt-Power-Capacitor-e1765777152302.webp 800w, https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/07\/elementor\/thumbs\/Three-Phase-Low-Voltage-Shunt-Power-Capacitor-e1765777152302-rg6gp412qqxvdx4g2po3uy58etbntwnf0dsjpmltpc.webp 400w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d9f56ce elementor-widget elementor-widget-heading\" data-id=\"d9f56ce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"The_Physics_of_Reactive_Power_Compensation\"><\/span>The Physics of Reactive Power Compensation<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e56a989 elementor-widget elementor-widget-text-editor\" data-id=\"e56a989\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"23\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Getting a bit more technical, the relationship between active power (P), reactive power (Q), and apparent power (S) forms what\u2019s called the power triangle. The power factor is the cosine of the angle between active and apparent power.<\/span><\/p><\/div><\/div><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"24\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">When capacitors are added:<\/span><\/p><\/div><\/div><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"25\" data-node-type=\"list\"><div class=\"node-content\" data-v-37d25bc6=\"\"><ul class=\"list-node list-disc\" data-v-79057d57=\"\" data-v-37d25bc6=\"\"><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">The inductive reactive power (QL) from the load remains the same<\/span><\/p><\/div><\/div><\/div><\/li><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">Capacitive reactive power (QC) is introduced<\/span><\/p><\/div><\/div><\/div><\/li><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">The net reactive power becomes QL &#8211; QC<\/span><\/p><\/div><\/div><\/div><\/li><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">The apparent power decreases<\/span><\/p><\/div><\/div><\/div><\/li><li class=\"list-item pl-1.5 my-2\" dir=\"auto\" data-v-7a618746=\"\" data-v-79057d57=\"\"><div class=\"markstream-vue markdown-renderer\" data-v-37d25bc6=\"\" data-v-7a618746=\"\"><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"0\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">The power factor angle reduces, improving the cosine value<\/span><\/p><\/div><\/div><\/div><\/li><\/ul><\/div><\/div><div class=\"node-slot\" data-v-37d25bc6=\"\" data-node-index=\"26\" data-node-type=\"paragraph\"><div class=\"node-content\" data-v-37d25bc6=\"\"><p class=\"paragraph-node\" dir=\"auto\" data-v-4e2afdbc=\"\" data-v-37d25bc6=\"\"><span class=\"whitespace-pre-wrap break-words text-node\" data-v-4e2afdbc=\"\">This is why power factor correction doesn\u2019t reduce the actual energy consumed by the equipment \u2014 it reduces the wasted energy circulating in the distribution system.<\/span><\/p><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2cfe323 elementor-widget elementor-widget-heading\" data-id=\"2cfe323\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Practical_Considerations_in_How_Power_Factor_Correction_Works\"><\/span>Practical Considerations in How Power Factor Correction Works<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d142b10 elementor-widget elementor-widget-heading\" data-id=\"d142b10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Harmonic Distortion<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa6bb49 elementor-widget elementor-widget-text-editor\" data-id=\"fa6bb49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Modern facilities often have variable frequency drives, LED lighting, and other non-linear loads that generate harmonics. Standard capacitors can amplify these harmonics or even create resonance conditions. That\u2019s why detuned reactors are often added in series with capacitors \u2014 they shift the resonant frequency away from problematic harmonics.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5420fa4 elementor-widget elementor-widget-heading\" data-id=\"5420fa4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Switching Transients<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-878062d elementor-widget elementor-widget-text-editor\" data-id=\"878062d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>When capacitor banks are energized, there\u2019s a brief inrush current. In automatic systems where stages switch frequently, this can cause voltage transients if not properly managed. Most APFC controllers include delay timers and soft-start features to minimize these effects. If you want to know more about power factor correction, please read\u00a0<a href=\"https:\/\/zmgs-global.com\/how-to-make-power-factor-correction.html\"><strong>How to make power factor correction<\/strong><\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-191a4cae e-con-full e-flex e-con e-parent\" data-id=\"191a4cae\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ff9ff01 elementor-widget__width-inherit elementor-widget elementor-widget-heading\" data-id=\"1ff9ff01\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"FAQ\"><\/span>FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-122237a8 elementor-widget elementor-widget-n-accordion\" data-id=\"122237a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordion. Open links with Enter or Space, close with Escape, and navigate with Arrow Keys\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3040\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-3040\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Does power factor correction reduce the electricity bill? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3040\" class=\"elementor-element elementor-element-56b2ff4d e-con-full e-flex e-con e-child\" data-id=\"56b2ff4d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-216be6d elementor-widget elementor-widget-text-editor\" data-id=\"216be6d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>It can, but not always in the way people expect. Power factor correction doesn\u2019t reduce the active energy consumption (kWh) \u2014 the equipment still uses the same amount of power to do its work. However, it reduces reactive power demand, which many utilities charge for separately. It also lowers demand charges in some rate structures and eliminates power factor penalties where they apply.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3041\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3041\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Can power factor correction improve voltage levels? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3041\" class=\"elementor-element elementor-element-6466ac77 e-con-full e-flex e-con e-child\" data-id=\"6466ac77\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1567ba2 elementor-widget elementor-widget-text-editor\" data-id=\"1567ba2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Yes, indirectly. By reducing the total current flowing through the distribution system, power factor correction reduces voltage drop across cables and transformers. This often results in slightly higher and more stable voltage at the load end, which can improve equipment performance and efficiency.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3042\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3042\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> How quickly does power factor correction respond to load changes? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3042\" class=\"elementor-element elementor-element-52224e12 e-con-full e-flex e-con e-child\" data-id=\"52224e12\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d8d1bc8 elementor-widget elementor-widget-text-editor\" data-id=\"d8d1bc8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>It depends on the type of system. Fixed capacitor banks don\u2019t respond at all \u2014 they provide constant compensation. Automatic systems with contactors typically respond within a few seconds. Thyristor-switched or active systems can respond in milliseconds, making them suitable for rapidly changing loads.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<script type=\"application\/ld+json\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Does power factor correction reduce the electricity bill?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It can, but not always in the way people expect. Power factor correction doesn\\u2019t reduce the active energy consumption (kWh) \\u2014 the equipment still uses the same amount of power to do its work. However, it reduces reactive power demand, which many utilities charge for separately. It also lowers demand charges in some rate structures and eliminates power factor penalties where they apply.\"}},{\"@type\":\"Question\",\"name\":\"Can power factor correction improve voltage levels?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, indirectly. By reducing the total current flowing through the distribution system, power factor correction reduces voltage drop across cables and transformers. This often results in slightly higher and more stable voltage at the load end, which can improve equipment performance and efficiency.\"}},{\"@type\":\"Question\",\"name\":\"How quickly does power factor correction respond to load changes?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It depends on the type of system. Fixed capacitor banks don\\u2019t respond at all \\u2014 they provide constant compensation. Automatic systems with contactors typically respond within a few seconds. Thyristor-switched or active systems can respond in milliseconds, making them suitable for rapidly changing loads.\"}}]}<\/script>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"Power factor is one of those electrical concepts that sounds more complicated than it actually is. At its core, it\u2019s about how efficiently electrical power is being used. When the power factor is low, a lot of current is flowing through the system without doing any real work \u2014 just bouncing back and forth between [&hellip;]","protected":false},"author":8,"featured_media":1400,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-2513","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge"],"acf":[],"_links":{"self":[{"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/posts\/2513","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/comments?post=2513"}],"version-history":[{"count":0,"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/posts\/2513\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/media\/1400"}],"wp:attachment":[{"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/media?parent=2513"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/categories?post=2513"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zmgs-global.com\/pl\/wp-json\/wp\/v2\/tags?post=2513"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}