{"id":237,"date":"2025-09-08T22:53:18","date_gmt":"2025-09-08T14:53:18","guid":{"rendered":"https:\/\/mediumslateblue-chimpanzee-835813.hostingersite.com\/?post_type=product&#038;p=237"},"modified":"2025-12-22T17:53:25","modified_gmt":"2025-12-22T09:53:25","slug":"jkg-series-phase-separation-compensation-capacitor-controller","status":"publish","type":"product","link":"https:\/\/zmgs-global.com\/fr\/product\/jkg-series-phase-separation-compensation-capacitor-controller","title":{"rendered":"Contr\u00f4leur de condensateur de compensation de s\u00e9paration de phase de la s\u00e9rie JKG (24 \u00e9tapes maximum)"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table des mati\u00e8res<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/zmgs-global.com\/fr\/product\/jkg-series-phase-separation-compensation-capacitor-controller\/#Code_and_Implication\" >Code et implications<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/zmgs-global.com\/fr\/product\/jkg-series-phase-separation-compensation-capacitor-controller\/#Application\" >Application<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/zmgs-global.com\/fr\/product\/jkg-series-phase-separation-compensation-capacitor-controller\/#Termination_function\" >Termination function<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/zmgs-global.com\/fr\/product\/jkg-series-phase-separation-compensation-capacitor-controller\/#Environmental_Conditions\" >Conditions environnementales<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/zmgs-global.com\/fr\/product\/jkg-series-phase-separation-compensation-capacitor-controller\/#Main_Technical_Data\" >Principales donn\u00e9es techniques<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/zmgs-global.com\/fr\/product\/jkg-series-phase-separation-compensation-capacitor-controller\/#Product_Size\" >Taille du produit<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Code_and_Implication\"><\/span><strong>Code et implications<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/yunpan.cdn.site.joinf.com\/5594599774213081\/HB4kk5wpWB.png\" alt=\"\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Application\"><\/span><strong>Application<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>ZHIMING&nbsp;&nbsp;<\/strong>brand of JKG Series Phase-Separation Compensation Controller.<\/p>\n\n\n\n<p>The JKG series is a new-generation phase-separation compensation capacitor controller designed for reactive power management in 0.4 kV, 50 Hz AC distribution systems. It integrates data acquisition, reactive power compensation, and system parameter analysis into a compact, intelligent unit.<br>Featuring a high-speed digital signal processor (DSP), the JKG controller performs precise real-time AC sampling. Its 128\u00d764 matrix LCD provides an intuitive interface for system monitoring, reactive compensation control, harmonic analysis, and adaptive frequency tracking. The device supports input frequency ranges from 45 Hz to 55 Hz, ensuring stable operation under varying grid conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Termination_function\"><\/span><strong>Termination function<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Real-Time Data Monitoring<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Phase A\/B\/C voltage, current, and power factor<\/li>\n\n\n\n<li>Switching the status (ON\/OFF) of capacitors for Phase A\/B\/C<\/li>\n\n\n\n<li>Active and reactive power for Phase A\/B\/C<\/li>\n\n\n\n<li>Total harmonic distortion (THD) of voltage and current waveforms (Phase A\/B\/C)<\/li>\n\n\n\n<li>System frequency<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Analyse harmonique<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Harmonic content (3rd, 5th, 7th, 9th, 11th, 13th) of phase voltage<\/li>\n\n\n\n<li>Harmonic content (3rd, 5th, 7th, 9th, 11th, 13th) of phase current<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Reactive Power Compensation<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Reactive power as the core control variable (sampling parameter)<\/li>\n\n\n\n<li>No switching oscillation during capacitor group operation<\/li>\n\n\n\n<li>Supports multiple compensation modes:\n<ul class=\"wp-block-list\">\n<li><strong>Y-type compensation<\/strong><\/li>\n\n\n\n<li><strong>A-type compensation<\/strong><\/li>\n\n\n\n<li><strong>Combined Y+A compensation<\/strong><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Environmental_Conditions\"><\/span><strong>Conditions environnementales<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Ambient Operating Temperature<\/strong>: \u221225\u00b0C to +65\u00b0C<br>The device is designed to operate reliably within this temperature range without performance degradation.<\/li>\n\n\n\n<li><strong>Humidit\u00e9 relative<\/strong>: Up to 90% at +20\u00b0C<br>Higher relative humidity is permissible at lower ambient temperatures. The device should not be subjected to condensation.<\/li>\n\n\n\n<li><strong>Altitude<\/strong>: Installation site altitude shall not exceed 2500 meters above sea level.<br>For installations above this altitude, derating or additional environmental protection measures may be required.<\/li>\n\n\n\n<li><strong>Atmospheric Conditions at Installation Site<\/strong>:\n<ul class=\"wp-block-list\">\n<li>The installation site must be free from flammable or explosive substances.<\/li>\n\n\n\n<li>No conductive dust or corrosive gases (such as hydrogen sulfide, chlorine, ammonia, etc.) should be present in the air.<\/li>\n\n\n\n<li>Adequate ventilation should be ensured to maintain internal temperature within operational limits.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Main_Technical_Data\"><\/span><strong>Principales donn\u00e9es techniques<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>Termination Function<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Supply Voltage<\/strong>: AC 220V \u00b120% \/ AC 380V \u00b120%<\/li>\n\n\n\n<li><strong>Sampling Voltage<\/strong>: AC 220V \u00b120% \/ AC 380V \u00b120%<\/li>\n\n\n\n<li><strong>Power Frequency<\/strong>: 50Hz \u00b15%<\/li>\n\n\n\n<li><strong>Sampling Current<\/strong>: 0\u20135A<\/li>\n<\/ul>\n\n\n\n<p><strong>Maximum Power Consumption<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>20W (depending on the power rating of the switching device)<\/li>\n<\/ul>\n\n\n\n<p><strong>Control Output Contacts<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>24 switching channels, each with DC 12V \u00d7 30mA output<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>Pr\u00e9cision de la mesure<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Voltage<\/strong>: \u00b10.5%<\/li>\n\n\n\n<li><strong>Current<\/strong>: \u00b10.5%<\/li>\n\n\n\n<li><strong>Active Power<\/strong>: \u00b11.0%<\/li>\n\n\n\n<li><strong>Reactive Power<\/strong>: \u00b11.0%<\/li>\n\n\n\n<li><strong>Fr\u00e9quence<\/strong>: \u00b10.5%<\/li>\n\n\n\n<li><strong>Facteur de puissance<\/strong>: \u00b11.0%<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p><strong>Param\u00e8tres de contr\u00f4le<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Control Sensitivity<\/strong>: 30mA<\/li>\n\n\n\n<li><strong>Target Power Factor (COS\u03c61)<\/strong>: 0.85\u20131.00 (step: 0.01, default: 1.00)<\/li>\n\n\n\n<li><strong>Target Power Factor (COS\u03c62)<\/strong>: 0.00\u20130.60 (step: 0.01, default: 2.2)<\/li>\n\n\n\n<li><strong>Threshold Coefficient<\/strong>: 0.5\u20131.2 (step: 0.1, default: 1.00)<\/li>\n\n\n\n<li><strong>Switching Delay (1)<\/strong>: 0\u2013600s (step: 1s \/ 0.02s, default: 30s)<\/li>\n\n\n\n<li><strong>Switching Delay (2)<\/strong>: 0\u2013300s (step: 1s, default: 30s)<\/li>\n\n\n\n<li><strong>Overvoltage Protection<\/strong>: 230\u2013280V \/ 400\u2013480V (step: 1V, default: 240V \/ 430V)<\/li>\n\n\n\n<li><strong>Undervoltage Protection<\/strong>: 180\u2013210V \/ 300\u2013360V (step: 1V, default: 190V \/ 330V)<\/li>\n\n\n\n<li><strong>Harmonic Voltage Over-limit<\/strong>: 0.0%\u201325.0% (step: 0.5%, default: 0.0%)<\/li>\n\n\n\n<li><strong>Harmonic Current Over-limit<\/strong>: 0.0%\u2013100.0% (step: 0.5%, default: 0.0%)<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Product_Size\"><\/span>Taille du produit<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Sp\u00e9cifications et dimensions<\/strong><\/h3>\n\n\n\n<p><strong>Panel Cutout Dimensions for JKG-24 Model<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Opening Dimensions<\/strong>: 138 mm \u00d7 138 mm (W \u00d7 H)<\/li>\n\n\n\n<li>This refers to the required cutout size in the panel or enclosure for proper flush mounting of the JKG-24 power factor controller. Ensure the panel cutout is clean and precise to guarantee secure installation and optimal display visibility.<\/li>\n<\/ul>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"Code and Implication Application ZHIMING&nbsp;&nbsp;brand of JKG Series Phase-Separation Compensation Controller. The JKG series is a new-generation phase-separation compensation capacitor controller designed for reactive power management in 0.4 kV, 50 Hz AC distribution systems. It integrates data acquisition, reactive power compensation, and system parameter analysis into a compact, intelligent unit.Featuring a high-speed digital signal processor [&hellip;]","protected":false},"featured_media":296,"menu_order":0,"template":"","meta":[],"products":[17],"class_list":["post-237","product","type-product","status-publish","has-post-thumbnail","hentry","products-split-phase-capacitor-controller"],"acf":[],"_links":{"self":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/product\/237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/product\/237\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/media\/296"}],"wp:attachment":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/media?parent=237"}],"wp:term":[{"taxonomy":"products","embeddable":true,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/products?post=237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}