{"id":1437,"date":"2025-12-01T15:14:12","date_gmt":"2025-12-01T07:14:12","guid":{"rendered":"https:\/\/zmgs-global.com\/product\/dgfc-series-reactive-power-auto-compen-sation-controllerstate-3"},"modified":"2025-12-23T10:17:56","modified_gmt":"2025-12-23T02:17:56","slug":"zm-spc-series-three-phase-unbalanced-device","status":"publish","type":"product","link":"https:\/\/zmgs-global.com\/fr\/product\/zm-spc-series-three-phase-unbalanced-device","title":{"rendered":"Dispositif asym\u00e9trique triphas\u00e9 de la s\u00e9rie ZM-SPC"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table des mati\u00e8res<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/zmgs-global.com\/fr\/product\/zm-spc-series-three-phase-unbalanced-device\/#Application\" >Application<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/zmgs-global.com\/fr\/product\/zm-spc-series-three-phase-unbalanced-device\/#Technical_Charactersitics\" >Caract\u00e9ristiques techniques<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/zmgs-global.com\/fr\/product\/zm-spc-series-three-phase-unbalanced-device\/#Main_technical_data\" >Principales donn\u00e9es techniques<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Application\"><\/span>Application<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Le dispositif de d\u00e9s\u00e9quilibre triphas\u00e9, un nouveau produit recherch\u00e9 par notre soci\u00e9t\u00e9 depuis longtemps et produit, est install\u00e9 en t\u00eate de ligne de distribution dans la r\u00e9gion, utilis\u00e9 pour r\u00e9duire le courant d\u00e9s\u00e9quilibr\u00e9 des trois phases \u00e0 l'avant du point d'installation des lignes de distribution (capable de limiter le taux de d\u00e9s\u00e9quilibre \u00e0 5%). Ce dispositif int\u00e8gre l'optimisation de la puissance r\u00e9active, la surveillance de l'\u00e9tat de fonctionnement de la zone de distribution, etc. Ce syst\u00e8me a adopt\u00e9 la technologie internationale avanc\u00e9e du niveau triphas\u00e9, capable d'augmenter la tension, de r\u00e9duire le taux de d\u00e9s\u00e9quilibre triphas\u00e9, d'am\u00e9liorer le facteur de puissance, de r\u00e9duire la perte de puissance et d'\u00e9conomiser la perte, d'am\u00e9liorer la qualit\u00e9 de l'\u00e9lectricit\u00e9. L'appareil peut fonctionner de mani\u00e8re stable sans n\u00e9cessiter de maintenance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Technical_Charactersitics\"><\/span>Caract\u00e9ristiques techniques<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>Compenser le courant de d\u00e9s\u00e9quilibre triphas\u00e9<\/strong> L'acquisition et l'analyse des donn\u00e9es par le contr\u00f4leur, l'action du lGBT, le transfert du courant d\u00e9s\u00e9quilibr\u00e9 de la phase de grand courant \u00e0 la phase de petit courant, la limitation du taux de d\u00e9s\u00e9quilibre des trois phases dans la limite de 5%.<br><strong>Compenser le courant r\u00e9actif<br><\/strong>L'acquisition des donn\u00e9es et leur analyse par le contr\u00f4leur permettent de calculer le manque de puissance r\u00e9active, de donner une r\u00e9ponse en quelques secondes, de compenser dynamiquement le courant r\u00e9actif, de maintenir le facteur de puissance \u00e0 plus de 0,98, d'\u00e9viter la chute de tension due au courant r\u00e9actif de la ligne et de r\u00e9duire les pertes en ligne.<br>R\u00e9guler la tension \u00c9chantillonner la tension \u00e0 partir du point de compensation, apr\u00e8s analyse par le contr\u00f4leur, identifier la tension dans la plage sp\u00e9cifi\u00e9e ou non, si non, ajuster le courant de sortie pour maintenir la tension de phase de chaque phase dans la plage sp\u00e9cifi\u00e9e.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Main_technical_data\"><\/span>Principales donn\u00e9es techniques<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Syst\u00e8me<\/strong>&nbsp;<strong>donn\u00e9es<\/strong><\/td><td>ZM-SPC30<\/td><td>ZM-SPC50<\/td><td>ZM-SPC100<\/td><\/tr><tr><td>Taux de vote nominal<\/td><td colspan=\"3\">400V<\/td><\/tr><tr><td>Plage de variation de la phase d'entr\u00e9e<\/td><td colspan=\"3\">40%~20%<\/td><\/tr><tr><td>Fr\u00e9quence du r\u00e9seau<\/td><td colspan=\"3\"> 50Hz\/60Hz (<strong>Gamme<\/strong> 45Hz-63Hz)<\/td><\/tr><tr><td>Efficacit\u00e9<\/td><td colspan=\"3\">&gt;97%<\/td><\/tr><tr><td>Structure du r\u00e9seau<\/td><td colspan=\"3\">Triphas\u00e9 trois fils, triphas\u00e9 quatre fils<\/td><\/tr><tr><td>Topologie du circuit<\/td><td colspan=\"3\">Trois niveaux<\/td><\/tr><tr><td colspan=\"4\"><strong>Performance<\/strong><\/td><\/tr><tr><td>Compensation de l'\u00e9quilibre triphas\u00e9<\/td><td colspan=\"3\">Compensation de d\u00e9s\u00e9quilibre \u00e0 50% ou moins<\/td><\/tr><tr><td>Courant nominal (ou courant de compensation d\u00e9s\u00e9quilibr\u00e9 maximal)<\/td><td>45A<\/td><td>75A<\/td><td>150A<\/td><\/tr><tr><td>Plage de compensation r\u00e9active<\/td><td colspan=\"3\">-1~1(r\u00e9glable)<\/td><\/tr><tr><td>Capacit\u00e9 de compensation de la puissance r\u00e9active<\/td><td>30kvar<\/td><td>50kvar<\/td><td>100kvar<\/td><\/tr><tr><td>Taux de compensation de la puissance r\u00e9active<\/td><td colspan=\"3\">&gt;99%<\/td><\/tr><tr><td>Temps de r\u00e9ponse<\/td><td colspan=\"3\">15ms<\/td><\/tr><tr><td>Fonction de protection<\/td><td colspan=\"3\">Protection contre les surtensions, protection contre les sous-tensions, protection contre les courts-circuits, protection contre les ponts invers\u00e9s, protection contre la surcompensation, protection contre la foudre Structure \u00e0 double couche<\/td><\/tr><tr><td>Fonction de distribution de l'\u00e9nergie<\/td><td colspan=\"2\">Analyse de puissance \u00e0 canal unique, avec fonction de protection contre la foudre de classe C<\/td><td>Analyse de puissance \u00e0 double canal, avec fonction de protection contre les \u00e9clairs de classe C<\/td><\/tr><tr><td colspan=\"4\"><strong>Communication<\/strong>&nbsp;<strong>contr\u00f4le<\/strong>&nbsp;<strong>fonction<\/strong><\/td><\/tr><tr><td>Afficher le contenu<\/td><td colspan=\"3\">Tension, courant, fr\u00e9quence, facteur de puissance, temp\u00e9rature de fonctionnement et autres informations de fonctionnement en temps r\u00e9el<\/td><\/tr><tr><td>Interface de communication<\/td><td colspan=\"3\">Port RS485\/CAN\/RS485\/CAN\/r\u00e9seau<\/td><\/tr><tr><td>Protocole<\/td><td colspan=\"3\">Modbus\/ protocole Modbus\/ protocole ma\u00eetre de l'\u00e9nergie<\/td><\/tr><tr><td colspan=\"4\"><strong>Caract\u00e9ristiques m\u00e9caniques<\/strong><\/td><\/tr><tr><td>Dimensions<\/td><td colspan=\"2\">L820\u00d7D350xH1180mm<\/td><td>L820xP400xH1180mm<\/td><\/tr><tr><td>Cokor<\/td><td colspan=\"3\">Acier inoxydable<\/td><\/tr><tr><td>Poids<\/td><td>58 kg<\/td><td>72 kg<\/td><td>135 kg<\/td><\/tr><tr><td>Installation<\/td><td colspan=\"3\">H\uff0cF<\/td><\/tr><tr><td>Angle de montage<\/td><td colspan=\"3\">&lt;5\u00b0<\/td><\/tr><tr><td colspan=\"4\"><strong>Environnement<\/strong><\/td><\/tr><tr><td>Temp\u00e9rature de fonctionnement<\/td><td colspan=\"3\">-10\u00b0\u2103~55\u2103<\/td><\/tr><tr><td>Alitude<\/td><td colspan=\"3\">1500 m\u00e8tres ou plus en accord avec GB\/T3859.2, veuillez utiliser le d\u00e9classement, ou contactez le concessionnaire.<\/td><\/tr><tr><td>IP Degr\u00e9 de protection<\/td><td colspan=\"3\">IP44<\/td><\/tr><tr><td>Capacit\u00e9 sismique<\/td><td colspan=\"3\">7Niveau<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"Application Three-phase unbalanced device, anew product researched by our company for longtime and produced,is installed in the head ofdistribution line in region,used to lessen theunbalanced current of three phases in the frontof installation point of the distribution lines(ableto limit the unbalance rate within 5%). This device integrates with reactive poweroptimization, monitoring running status of thedistribution [&hellip;]","protected":false},"featured_media":1458,"menu_order":0,"template":"","meta":[],"products":[28],"class_list":["post-1437","product","type-product","status-publish","has-post-thumbnail","hentry","products-panel-cabinet"],"acf":[],"_links":{"self":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/product\/1437","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/product\/1437\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/media\/1458"}],"wp:attachment":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/media?parent=1437"}],"wp:term":[{"taxonomy":"products","embeddable":true,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/products?post=1437"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}