{"id":2155,"date":"2026-02-10T14:51:12","date_gmt":"2026-02-10T06:51:12","guid":{"rendered":"https:\/\/zmgs-global.com\/?p=2155"},"modified":"2026-02-26T11:12:17","modified_gmt":"2026-02-26T03:12:17","slug":"how-to-check-if-a-capacitor-bank-is-working","status":"publish","type":"post","link":"https:\/\/zmgs-global.com\/fr\/how-to-check-if-a-capacitor-bank-is-working.html","title":{"rendered":"Comment v\u00e9rifier si une banque de condensateurs fonctionne ou non ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2155\" class=\"elementor elementor-2155\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-acf3dd7 e-flex e-con-boxed e-con e-parent\" data-id=\"acf3dd7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-de783d6 elementor-widget elementor-widget-text-editor\" data-id=\"de783d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Une batterie de condensateurs qui ne fonctionne pas correctement ne fait pas que gaspiller de l'argent. Elle ne corrige pas le facteur de puissance, laisse s'accumuler les p\u00e9nalit\u00e9s des services publics et cr\u00e9e potentiellement des risques pour la s\u00e9curit\u00e9. Pourtant, de nombreuses installations fonctionnent pendant des ann\u00e9es sans que personne ne v\u00e9rifie leur bon fonctionnement.<\/p><p>La question de savoir comment v\u00e9rifier si un <a href=\"https:\/\/zmgs-global.com\/fr\/products\/\"><strong>batterie de condensateurs<\/strong> <\/a>fonctionne semble simple. Dans la pratique, plusieurs approches sont n\u00e9cessaires, de la simple observation visuelle aux mesures \u00e9lectriques d\u00e9taill\u00e9es. Certaines v\u00e9rifications ne prennent que quelques minutes avec des outils de base. D'autres n\u00e9cessitent un \u00e9quipement et une expertise sp\u00e9cialis\u00e9s.<\/p><p>En sachant ce qu'il faut rechercher et quand il faut faire appel \u00e0 une aide professionnelle, les installations de batteries de condensateurs fonctionnent comme pr\u00e9vu.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b6da43 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"4b6da43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/High-Voltage-Shunt-Power-Capacitor.webp\" class=\"attachment-full size-full wp-image-1593\" alt=\"Condensateur de puissance haute tension\" srcset=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/High-Voltage-Shunt-Power-Capacitor.webp 400w, https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/High-Voltage-Shunt-Power-Capacitor-150x150.webp 150w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4eebb53 elementor-widget elementor-widget-heading\" data-id=\"4eebb53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table des mati\u00e8res<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/zmgs-global.com\/fr\/how-to-check-if-a-capacitor-bank-is-working.html\/#Visual_Inspection_of_a_Capacitor_Bank\" >Inspection visuelle d'une batterie de condensateurs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/zmgs-global.com\/fr\/how-to-check-if-a-capacitor-bank-is-working.html\/#Electrical_Testing_Methods_for_Capacitor_Bank_Verification\" >M\u00e9thodes de contr\u00f4le \u00e9lectrique pour la v\u00e9rification des batteries de condensateurs<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/zmgs-global.com\/fr\/how-to-check-if-a-capacitor-bank-is-working.html\/#Monitoring_Capacitor_Bank_Performance_Over_Time\" >Contr\u00f4le des performances des batteries de condensateurs dans le temps<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/zmgs-global.com\/fr\/how-to-check-if-a-capacitor-bank-is-working.html\/#FAQ\" >FAQ<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Visual_Inspection_of_a_Capacitor_Bank\"><\/span>Inspection visuelle d'une batterie de condensateurs<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32a29c7 elementor-widget elementor-widget-heading\" data-id=\"32a29c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ce qu'il faut rechercher \u00e0 l'ext\u00e9rieur<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28c64f2 elementor-widget elementor-widget-text-editor\" data-id=\"28c64f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>L'inspection visuelle permet de d\u00e9tecter un nombre surprenant de probl\u00e8mes, \u00e0 condition qu'elle soit effectu\u00e9e r\u00e9guli\u00e8rement. L'\u00e9tat physique des condensateurs en dit long sur leur sant\u00e9 interne.<\/p><p>Les signes d'alerte visibles de l'ext\u00e9rieur sont les suivants<\/p><ul><li>Bombement ou gonflement des bo\u00eetiers de condensateurs<\/li><li>Fuite d'huile au niveau des joints ou des raccords du carter<\/li><li>Marques de br\u00fblure ou d\u00e9coloration sur les \u00e9tuis<\/li><li>Corrosion des bornes et des connexions<\/li><li>Isolation du c\u00e2blage endommag\u00e9e ou d\u00e9t\u00e9rior\u00e9e<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-16b01ab elementor-widget elementor-widget-heading\" data-id=\"16b01ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Conditions d'environnement et de montage<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b793833 elementor-widget elementor-widget-text-editor\" data-id=\"b793833\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Au-del\u00e0 des condensateurs eux-m\u00eames, l'\u00e9tat g\u00e9n\u00e9ral de l'installation est important. L'accumulation de poussi\u00e8re r\u00e9duit l'efficacit\u00e9 du refroidissement. Les ouvertures de ventilation obstru\u00e9es provoquent une surchauffe. Un montage mal ajust\u00e9 permet d'endommager le condensateur par les vibrations au fil du temps.<\/p><p>Une \u00e9valuation environnementale rapide comprend des v\u00e9rifications :<\/p><ol><li>Les voies d'a\u00e9ration restent claires et d\u00e9gag\u00e9es<\/li><li>La temp\u00e9rature ambiante reste dans les limites nominales<\/li><li>Absence d'intrusion d'eau ou d'humidit\u00e9 excessive<\/li><li>Les connexions restent \u00e9tanches sans signes d'\u00e9chauffement<\/li><li>Les dispositifs de protection semblent intacts et correctement r\u00e9gl\u00e9s<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94872fa elementor-widget elementor-widget-heading\" data-id=\"94872fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Electrical_Testing_Methods_for_Capacitor_Bank_Verification\"><\/span>M\u00e9thodes de contr\u00f4le \u00e9lectrique pour la v\u00e9rification des batteries de condensateurs<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80eb90c elementor-widget elementor-widget-heading\" data-id=\"80eb90c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Mesures de base du courant<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c0eeee6 elementor-widget elementor-widget-text-editor\" data-id=\"c0eeee6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<table><tbody><tr><td><p><strong><b>R\u00e9sultat du test<\/b><\/strong><\/p><\/td><td><p><strong><b>Interpr\u00e9tation possible<\/b><\/strong><\/p><\/td><\/tr><tr><td><p>Courant au niveau attendu<\/p><\/td><td><p>Le banc de condensateurs fonctionne probablement normalement<\/p><\/td><\/tr><tr><td><p>Courant tr\u00e8s faible<\/p><\/td><td><p>Certains \u00e9l\u00e9ments n'ont pas \u00e9t\u00e9 ouverts<\/p><\/td><\/tr><tr><td><p>Courant plus \u00e9lev\u00e9 que pr\u00e9vu<\/p><\/td><td><p>Probl\u00e8mes d'harmoniques ou erreurs de mesure possibles<\/p><\/td><\/tr><tr><td><p>Pas de consommation de courant<\/p><\/td><td><p>D\u00e9faillance compl\u00e8te, fusible grill\u00e9 ou contacteur ouvert<\/p><\/td><\/tr><tr><td><p>Courants de phase d\u00e9s\u00e9quilibr\u00e9s<\/p><\/td><td><p>D\u00e9faillance d'un \u00e9l\u00e9ment interne dans une ou plusieurs phases<\/p><\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3565aa0 elementor-widget elementor-widget-text-editor\" data-id=\"3565aa0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Une pince amp\u00e8rem\u00e9trique rend ce contr\u00f4le rapide et non intrusif. Comparez les valeurs mesur\u00e9es aux valeurs nominales indiqu\u00e9es sur la plaque signal\u00e9tique, ajust\u00e9es \u00e0 la tension r\u00e9elle. Le courant doit \u00eatre proportionnel - une tension plus faible signifie un courant plus faible, une tension plus \u00e9lev\u00e9e signifie un courant plus \u00e9lev\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f2bb3c elementor-widget elementor-widget-heading\" data-id=\"1f2bb3c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tests de capacit\u00e9 et de facteur de puissance<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb4e13f elementor-widget elementor-widget-text-editor\" data-id=\"eb4e13f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Une \u00e9valuation plus d\u00e9taill\u00e9e n\u00e9cessite de mesurer les valeurs de capacit\u00e9 r\u00e9elles et de les comparer aux sp\u00e9cifications de la plaque signal\u00e9tique. Les tests de capacit\u00e9 permettent d'identifier les unit\u00e9s d\u00e9grad\u00e9es avant qu'une panne compl\u00e8te ne se produise.<\/p><p>Le test du facteur de puissance - en particulier la mesure du facteur de dissipation ou tan delta - r\u00e9v\u00e8le l'\u00e9tat di\u00e9lectrique. Les condensateurs sains pr\u00e9sentent un facteur de dissipation tr\u00e8s faible. Des valeurs en hausse indiquent un vieillissement ou une contamination qui finit par entra\u00eener une d\u00e9faillance.<\/p><p>Ces tests requi\u00e8rent g\u00e9n\u00e9ralement<\/p><ul><li>La batterie de condensateurs doit \u00eatre mise hors tension et isol\u00e9e.<\/li><li>Respect des proc\u00e9dures de d\u00e9charge<\/li><li>\u00c9quipement d'essai sp\u00e9cialis\u00e9 (capacim\u00e8tre, ensemble de test du facteur de puissance)<\/li><li>Connaissances techniques pour interpr\u00e9ter correctement les r\u00e9sultats<\/li><\/ul><p>La plupart des installations ne disposent pas de l'\u00e9quipement n\u00e9cessaire pour effectuer des tests de capacit\u00e9 sur place. Il est plus judicieux de confier les tests p\u00e9riodiques \u00e0 des entrepreneurs qualifi\u00e9s que d'acheter des instruments sp\u00e9cialis\u00e9s qui ne seront utilis\u00e9s qu'occasionnellement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f380137 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"f380137\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/high-voltage-power-capacitor-400x400-c.webp\" class=\"attachment-full size-full wp-image-1589\" alt=\"condensateur de puissance triphas\u00e9\" srcset=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/high-voltage-power-capacitor-400x400-c.webp 400w, https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/high-voltage-power-capacitor-400x400-c-150x150.webp 150w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f1c32f9 elementor-widget elementor-widget-heading\" data-id=\"f1c32f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"> \u00c9valuation par imagerie thermique<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-05d6bbf elementor-widget elementor-widget-text-editor\" data-id=\"05d6bbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>L'imagerie thermique infrarouge est devenue inestimable pour l'\u00e9valuation des batteries de condensateurs. Les points chauds r\u00e9v\u00e8lent des probl\u00e8mes invisibles \u00e0 l'\u0153il nu - connexions desserr\u00e9es, \u00e9l\u00e9ments surcharg\u00e9s, d\u00e9fauts internes g\u00e9n\u00e9rant de la chaleur.<\/p><p>Le balayage thermique donne de meilleurs r\u00e9sultats en fonctionnement normal, dans des conditions de charge typiques. La comparaison des temp\u00e9ratures de composants similaires permet d'identifier les valeurs aberrantes. Un condensateur fonctionnant \u00e0 une temp\u00e9rature nettement sup\u00e9rieure \u00e0 celle de ses voisins justifie une investigation, m\u00eame en l'absence d'autres sympt\u00f4mes \u00e9vidents.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-134b5bf elementor-widget elementor-widget-heading\" data-id=\"134b5bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Monitoring_Capacitor_Bank_Performance_Over_Time\"><\/span>Contr\u00f4le des performances des batteries de condensateurs dans le temps<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db800ae elementor-widget elementor-widget-heading\" data-id=\"db800ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Suivre les tendances du facteur de puissance<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53c7375 elementor-widget elementor-widget-text-editor\" data-id=\"53c7375\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Le contr\u00f4le permanent le plus pratique consiste peut-\u00eatre \u00e0 surveiller simplement le facteur de puissance au niveau du compteur d'\u00e9lectricit\u00e9 ou du tableau de distribution principal. Si le facteur de puissance se maintient aux niveaux vis\u00e9s, la batterie de condensateurs fait vraisemblablement son travail. Si le facteur de puissance diminue au fil du temps, quelque chose a chang\u00e9.<\/p><p>Les factures des services publics fournissent souvent des donn\u00e9es mensuelles sur le facteur de puissance. Le suivi de ces informations r\u00e9v\u00e8le une d\u00e9gradation progressive qui pourrait autrement passer inaper\u00e7ue. Les changements soudains donnent lieu \u00e0 une enqu\u00eate imm\u00e9diate.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1541b53 elementor-widget elementor-widget-heading\" data-id=\"1541b53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Diagnostic automatique du syst\u00e8me<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5113bd1 elementor-widget elementor-widget-text-editor\" data-id=\"5113bd1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Les batteries de condensateurs automatiques modernes comprennent des contr\u00f4leurs qui surveillent leur propre fonctionnement. Des sorties d'alarme indiquent les conditions de d\u00e9faillance. Des journaux d'exploitation enregistrent les activit\u00e9s de commutation et les param\u00e8tres mesur\u00e9s. Des interfaces de communication permettent une surveillance \u00e0 distance.<\/p><p>En tirant parti de ces diagnostics int\u00e9gr\u00e9s - en examinant r\u00e9ellement les donn\u00e9es plut\u00f4t qu'en les ignorant - les probl\u00e8mes sont d\u00e9tect\u00e9s \u00e0 un stade pr\u00e9coce. De nombreuses d\u00e9faillances donnent des signes d'avertissement visibles dans les tendances de fonctionnement bien avant que des sympt\u00f4mes \u00e9vidents n'apparaissent. Si vous souhaitez en savoir plus sur la batterie de condensateurs, lisez le document suivant <a href=\"https:\/\/zmgs-global.com\/fr\/what-is-the-lifespan-of-a-capacitor-bank.html\/\"><strong>Quelle est la dur\u00e9e de vie d'une batterie de condensateurs ?<\/strong><\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4476aff elementor-widget elementor-widget-heading\" data-id=\"4476aff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"FAQ\"><\/span>FAQ<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18d497a elementor-widget elementor-widget-n-accordion\" data-id=\"18d497a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accord\u00e9on. Ouvrez les liens avec Enter ou Space, fermez-les avec Escape et naviguez avec les touches fl\u00e9ch\u00e9es.\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2600\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-2600\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00c0 quelle fr\u00e9quence une batterie de condensateurs doit-elle \u00eatre inspect\u00e9e ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2600\" class=\"elementor-element elementor-element-a6d1ae2 e-con-full e-flex e-con e-child\" data-id=\"a6d1ae2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0bbf866 elementor-widget elementor-widget-text-editor\" data-id=\"0bbf866\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>La fr\u00e9quence des inspections d\u00e9pend de l'environnement d'exploitation et de la criticit\u00e9 de l'installation. La plupart des installations industrielles b\u00e9n\u00e9ficient d'une inspection visuelle trimestrielle et d'une \u00e9valuation \u00e9lectrique plus d\u00e9taill\u00e9e annuelle. Les environnements difficiles - temp\u00e9ratures \u00e9lev\u00e9es, poussi\u00e8res, fortes charges harmoniques - justifient une attention plus fr\u00e9quente, voire des contr\u00f4les visuels mensuels. Les installations des services publics suivent souvent des calendriers de maintenance sp\u00e9cifi\u00e9s par des normes de fiabilit\u00e9. La cl\u00e9 est la coh\u00e9rence plut\u00f4t qu'une attention occasionnelle et al\u00e9atoire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2601\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2601\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Une batterie de condensateurs peut-elle \u00eatre test\u00e9e sous tension ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2601\" class=\"elementor-element elementor-element-e65e8b7 e-con-full e-flex e-con e-child\" data-id=\"e65e8b7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e278241 elementor-widget elementor-widget-text-editor\" data-id=\"e278241\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Certains tests peuvent \u00eatre effectu\u00e9s en toute s\u00e9curit\u00e9 sur des \u00e9quipements sous tension, tandis que d'autres n\u00e9cessitent imp\u00e9rativement une mise hors tension. La mesure du courant \u00e0 l'aide de pinces amp\u00e8rem\u00e9triques se fait en toute s\u00e9curit\u00e9 avec une technique appropri\u00e9e et un \u00e9quipement de protection individuelle ad\u00e9quat. L'imagerie thermique exige sp\u00e9cifiquement que l'\u00e9quipement soit sous tension et sous charge. En revanche, les tests de capacit\u00e9 et l'inspection interne n\u00e9cessitent une mise hors tension compl\u00e8te, des proc\u00e9dures de verrouillage\/\u00e9tiquetage appropri\u00e9es et une d\u00e9charge v\u00e9rifi\u00e9e de l'\u00e9nergie stock\u00e9e. Les condensateurs conservent leur charge m\u00eame apr\u00e8s avoir \u00e9t\u00e9 d\u00e9connect\u00e9s - ils doivent \u00eatre d\u00e9charg\u00e9s \u00e0 l'aide de r\u00e9sistances appropri\u00e9es avant tout travail pratique.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2602\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2602\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> Qu'est-ce qui indique qu'une batterie de condensateurs doit \u00eatre remplac\u00e9e plut\u00f4t que r\u00e9par\u00e9e ? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2602\" class=\"elementor-element elementor-element-57434bf e-con-full e-flex e-con e-child\" data-id=\"57434bf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-15ac788 elementor-widget elementor-widget-text-editor\" data-id=\"15ac788\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Plusieurs facteurs poussent \u00e0 prendre la d\u00e9cision de remplacer les condensateurs. Lorsque plusieurs unit\u00e9s de condensateurs sont tomb\u00e9es en panne dans un court laps de temps, les unit\u00e9s restantes d'un \u00e2ge similaire sont probablement confront\u00e9es \u00e0 une panne imminente - continuer \u00e0 remplacer les unit\u00e9s individuelles devient peu pratique. Si la batterie de condensateurs utilise des mat\u00e9riaux di\u00e9lectriques obsol\u00e8tes ou contient des PCB, le remplacement est obligatoire, quel que soit l'\u00e9tat de fonctionnement. Lorsque les co\u00fbts de r\u00e9paration approchent 50-60% du co\u00fbt de remplacement, l'investissement dans un nouvel \u00e9quipement b\u00e9n\u00e9ficiant d'une nouvelle garantie et d'une conception moderne est plus judicieux d'un point de vue \u00e9conomique.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"A capacitor bank that isn&#8217;t working properly does more than just waste money. It leaves power factor uncorrected, allows utility penalties to accumulate, and potentially creates safety hazards. Yet many installations run for years without anyone actually verifying proper operation. The question of how to check if a capacitor bank is working seems straightforward. In [&hellip;]","protected":false},"author":8,"featured_media":760,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-2155","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge"],"acf":[],"_links":{"self":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/posts\/2155","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/comments?post=2155"}],"version-history":[{"count":0,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/posts\/2155\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/media\/760"}],"wp:attachment":[{"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/media?parent=2155"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/categories?post=2155"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zmgs-global.com\/fr\/wp-json\/wp\/v2\/tags?post=2155"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}