{"id":2171,"date":"2026-02-20T11:45:53","date_gmt":"2026-02-20T03:45:53","guid":{"rendered":"https:\/\/zmgs-global.com\/?p=2171"},"modified":"2026-02-26T11:13:35","modified_gmt":"2026-02-26T03:13:35","slug":"how-capacitor-bank-is-used-to-improve-power-factor","status":"publish","type":"post","link":"https:\/\/zmgs-global.com\/es\/how-capacitor-bank-is-used-to-improve-power-factor.html","title":{"rendered":"\u00bfC\u00f3mo se utiliza un banco de condensadores para mejorar el factor de potencia?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2171\" class=\"elementor elementor-2171\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a7d89d5 e-flex e-con-boxed e-con e-parent\" data-id=\"a7d89d5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a5cb50 elementor-widget elementor-widget-heading\" data-id=\"8a5cb50\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/zmgs-global.com\/es\/how-capacitor-bank-is-used-to-improve-power-factor.html\/#The_Connection_Between_a_Capacitor_Bank_and_Power_Factor\" >La relaci\u00f3n entre un banco de condensadores y el factor de potencia<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/zmgs-global.com\/es\/how-capacitor-bank-is-used-to-improve-power-factor.html\/#What_Power_Factor_Actually_Means_in_Electrical_Systems\" >Qu\u00e9 significa realmente el factor de potencia en los sistemas el\u00e9ctricos<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/zmgs-global.com\/es\/how-capacitor-bank-is-used-to-improve-power-factor.html\/#How_a_Capacitor_Bank_Corrects_Poor_Power_Factor\" >C\u00f3mo un banco de condensadores corrige un factor de potencia deficiente<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/zmgs-global.com\/es\/how-capacitor-bank-is-used-to-improve-power-factor.html\/#Types_of_Capacitor_Bank_Installations_for_Power_Factor_Improvement\" >Tipos de instalaciones de bancos de condensadores para la mejora del factor de potencia<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/zmgs-global.com\/es\/how-capacitor-bank-is-used-to-improve-power-factor.html\/#Benefits_Beyond_Power_Factor_When_Using_a_Capacitor_Bank\" >Ventajas m\u00e1s all\u00e1 del factor de potencia al utilizar un banco de condensadores<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/zmgs-global.com\/es\/how-capacitor-bank-is-used-to-improve-power-factor.html\/#Sizing_Considerations_for_Effective_Power_Factor_Improvement\" >Consideraciones sobre el dimensionamiento para una mejora eficaz del factor de potencia<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/zmgs-global.com\/es\/how-capacitor-bank-is-used-to-improve-power-factor.html\/#FAQ\" >Preguntas frecuentes<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"The_Connection_Between_a_Capacitor_Bank_and_Power_Factor\"><\/span>La relaci\u00f3n entre un banco de condensadores y el factor de potencia<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fceaa41 elementor-widget elementor-widget-text-editor\" data-id=\"fceaa41\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Las facturas de electricidad no dejan de subir. Para las instalaciones industriales y comerciales, las multas por factor de potencia suelen ser la gota que colma el vaso: cargos adicionales por un uso ineficiente de la energ\u00eda. \u00bfCu\u00e1l es la soluci\u00f3n que se encuentra en innumerables salas el\u00e9ctricas? Un <a href=\"https:\/\/zmgs-global.com\/es\/products\/\"><strong>banco de condensadores<\/strong><\/a>.<\/p><p>Esta tecnolog\u00eda existe desde hace d\u00e9cadas. No tiene nada de revolucionario. Sin embargo, muchos administradores de instalaciones a\u00fan no comprenden del todo c\u00f3mo funcionan realmente estos dispositivos para mejorar el factor de potencia. El concepto parece abstracto hasta que alguien explica los principios f\u00edsicos subyacentes en t\u00e9rminos pr\u00e1cticos.<\/p><p>Comprender esta relaci\u00f3n ayuda a justificar las decisiones de inversi\u00f3n y a optimizar las instalaciones para obtener el m\u00e1ximo beneficio.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-170a3bc elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"170a3bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"432\" src=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/07\/capacitor-bank061-e1770104994539.webp\" class=\"attachment-full size-full wp-image-62\" alt=\"banco de condensadores\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78bb0de elementor-widget elementor-widget-heading\" data-id=\"78bb0de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"What_Power_Factor_Actually_Means_in_Electrical_Systems\"><\/span>Qu\u00e9 significa realmente el factor de potencia en los sistemas el\u00e9ctricos<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30e9f16 elementor-widget elementor-widget-heading\" data-id=\"30e9f16\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Potencia activa frente a potencia reactiva<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f681cb7 elementor-widget elementor-widget-text-editor\" data-id=\"f681cb7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Las cargas el\u00e9ctricas consumen energ\u00eda de dos formas. La potencia real \u2014medida en kilovatios\u2014 realiza un trabajo efectivo. Hace girar motores, produce luz y genera calor. Esto es lo que las instalaciones realmente necesitan.<\/p><p>La potencia reactiva es diferente. Se mide en kVAR y circula de un lado a otro entre la fuente y la carga sin generar potencia \u00fatil. Los motores, los transformadores y la iluminaci\u00f3n fluorescente necesitan potencia reactiva para generar campos magn\u00e9ticos. No pueden funcionar sin ella.<\/p><p>\u00bfCu\u00e1l es el problema? La potencia reactiva consume capacidad del sistema sin contribuir a la producci\u00f3n efectiva.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3970db elementor-widget elementor-widget-heading\" data-id=\"e3970db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"> Definici\u00f3n del factor de potencia<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b1644f elementor-widget elementor-widget-text-editor\" data-id=\"6b1644f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>El factor de potencia representa la relaci\u00f3n entre la potencia real y la potencia aparente (la suma de la potencia real y la reactiva). Un factor de potencia de 1,0 significa que toda la potencia suministrada se est\u00e1 utilizando de manera productiva. Es decir, una eficiencia perfecta.<\/p><p>La mayor\u00eda de las instalaciones industriales funcionan, por lo general, con un factor de potencia de entre 0,75 y 0,85. Los motores y otras cargas inductivas reducen este valor. A las empresas de servicios p\u00fablicos no les gusta esto, ya que les obliga a generar y transmitir m\u00e1s corriente de la que las instalaciones consumen realmente de forma \u00fatil.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-026a34f elementor-widget elementor-widget-heading\" data-id=\"026a34f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"How_a_Capacitor_Bank_Corrects_Poor_Power_Factor\"><\/span>C\u00f3mo un banco de condensadores corrige un factor de potencia deficiente<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3bad1e8 elementor-widget elementor-widget-heading\" data-id=\"3bad1e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">El principio de compensaci\u00f3n<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a819f72 elementor-widget elementor-widget-text-editor\" data-id=\"a819f72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Las cargas inductivas (motores, transformadores) hacen que la corriente vaya por detr\u00e1s de la tensi\u00f3n. Las cargas capacitivas hacen que la corriente vaya por delante de la tensi\u00f3n. Cuando se combinan adecuadamente, estos efectos se anulan entre s\u00ed.<\/p><p>Un banco de condensadores suministra potencia reactiva a nivel local. En lugar de obtener corriente reactiva de la red el\u00e9ctrica a trav\u00e9s de kil\u00f3metros de l\u00edneas de transmisi\u00f3n, los equipos la obtienen de los condensadores instalados en las inmediaciones, a veces incluso en la misma sala.<\/p><p>El resultado:<\/p><ul><li>Disminuye el consumo de electricidad de la red p\u00fablica<\/li><li>El factor de potencia se aproxima a la unidad<\/li><li>Las p\u00e9rdidas del sistema se reducen<\/li><li>Se libera capacidad<\/li><\/ul><p>Es realmente elegante. La f\u00edsica simplemente funciona.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7528e20 elementor-widget elementor-widget-heading\" data-id=\"7528e20\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ejemplo pr\u00e1ctico<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45f4170 elementor-widget elementor-widget-text-editor\" data-id=\"45f4170\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Imaginemos una planta de fabricaci\u00f3n que consume 500 kW de potencia activa con un factor de potencia de 0,75. La potencia aparente es de 667 kVA, y la potencia reactiva alcanza los 441 kVAR.<\/p><p>La instalaci\u00f3n de un banco de condensadores con una potencia nominal de 300 kVAR lo cambia todo. La demanda reactiva de la red el\u00e9ctrica se reduce a 141 kVAR. El factor de potencia mejora hasta alcanzar aproximadamente 0,96. La potencia aparente se reduce a 520 kVA.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f62d79 elementor-widget elementor-widget-text-editor\" data-id=\"7f62d79\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<table><tbody><tr><td><p><strong><b>Par\u00e1metro<\/b><\/strong><\/p><\/td><td><p><strong><b>Antes de la correcci\u00f3n<\/b><\/strong><\/p><\/td><td><p><strong><b>Tras el banco de condensadores de 300 kVAR<\/b><\/strong><\/p><\/td><\/tr><tr><td><p>El poder real<\/p><\/td><td><p>500 kW<\/p><\/td><td><p>500 kW<\/p><\/td><\/tr><tr><td><p>Potencia reactiva<\/p><\/td><td><p>441 kVAR<\/p><\/td><td><p>141 kVAR<\/p><\/td><\/tr><tr><td><p>Potencia aparente<\/p><\/td><td><p>667 kVA<\/p><\/td><td><p>520 kVA<\/p><\/td><\/tr><tr><td><p>Factor de potencia<\/p><\/td><td><p>0.75<\/p><\/td><td><p>0.96<\/p><\/td><\/tr><tr><td><p>Consumo de corriente<\/p><\/td><td><p>M\u00e1s alto<\/p><\/td><td><p>22% Inferior<\/p><\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de1612b elementor-widget elementor-widget-heading\" data-id=\"de1612b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Types_of_Capacitor_Bank_Installations_for_Power_Factor_Improvement\"><\/span>Tipos de instalaciones de bancos de condensadores para la mejora del factor de potencia<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-df7b750 elementor-widget elementor-widget-heading\" data-id=\"df7b750\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Remuneraci\u00f3n fija<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-763bf71 elementor-widget elementor-widget-text-editor\" data-id=\"763bf71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>El m\u00e9todo m\u00e1s sencillo. Un banco de condensadores fijo proporciona potencia reactiva constante independientemente de las variaciones de carga. Funciona bien cuando:<\/p><ol><li>Las cargas se mantienen relativamente estables<\/li><li>La demanda reactiva m\u00ednima se mantiene estable<\/li><li>Las restricciones presupuestarias limitan las opciones<\/li><li>La simplicidad es m\u00e1s importante que la optimizaci\u00f3n<\/li><\/ol><p>Las instalaciones fijas tienen un costo inicial menor, pero pueden compensar en exceso durante los periodos de baja carga, lo que podr\u00eda provocar problemas de factor de potencia adelantado.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25d926f elementor-widget elementor-widget-heading\" data-id=\"25d926f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Compensaci\u00f3n autom\u00e1tica<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2cac642 elementor-widget elementor-widget-text-editor\" data-id=\"2cac642\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>M\u00e1s sofisticados. Los sistemas autom\u00e1ticos de bancos de condensadores utilizan controladores que supervisan el factor de potencia de forma continua. Estos activan y desactivan las etapas de condensadores a medida que var\u00edan las cargas.<\/p><p>Las ventajas incluyen:<\/p><ul><li>Factor de potencia constante en condiciones variables<\/li><li>Sin sobrecorrecci\u00f3n con cargas ligeras<\/li><li>Mejor optimizaci\u00f3n del nivel de correcci\u00f3n<\/li><li>Menor riesgo de problemas de resonancia<\/li><\/ul><p>El controlador mide la demanda reactiva y ajusta la compensaci\u00f3n en consecuencia. Algunos controladores modernos incluso se adaptan a las condiciones arm\u00f3nicas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-82c78ef elementor-widget elementor-widget-heading\" data-id=\"82c78ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Correcci\u00f3n individual frente a correcci\u00f3n central<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b2ac64 elementor-widget elementor-widget-text-editor\" data-id=\"3b2ac64\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>La ubicaci\u00f3n tambi\u00e9n es importante. La correcci\u00f3n central consiste en colocar el banco de condensadores en el panel de distribuci\u00f3n principal. Esto mejora el factor de potencia que percibe la empresa de servicios p\u00fablicos, pero no reduce las p\u00e9rdidas dentro de la instalaci\u00f3n.<\/p><p>La correcci\u00f3n individual \u2014condensadores en cada motor o carga\u2014 maximiza la eficiencia interna al reducir la corriente en todo el sistema de distribuci\u00f3n. Es m\u00e1s costosa y compleja, pero t\u00e9cnicamente superior.<\/p><p>Muchas instalaciones utilizan enfoques h\u00edbridos. La correcci\u00f3n central se encarga de las necesidades b\u00e1sicas, mientras que la correcci\u00f3n individual se ocupa de las cargas pesadas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-da2764f elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"da2764f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/high-voltage-power-capacitor-400x400-c.webp\" class=\"attachment-full size-full wp-image-1589\" alt=\"condensador trif\u00e1sico\" srcset=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/high-voltage-power-capacitor-400x400-c.webp 400w, https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/high-voltage-power-capacitor-400x400-c-150x150.webp 150w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b6a85bf elementor-widget elementor-widget-heading\" data-id=\"b6a85bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Benefits_Beyond_Power_Factor_When_Using_a_Capacitor_Bank\"><\/span>Ventajas m\u00e1s all\u00e1 del factor de potencia al utilizar un banco de condensadores<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-960c9cb elementor-widget elementor-widget-heading\" data-id=\"960c9cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Capacidad del sistema liberada<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65bd430 elementor-widget elementor-widget-text-editor\" data-id=\"65bd430\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Una corriente m\u00e1s baja significa que los cables, los transformadores y los equipos de conmutaci\u00f3n soportan menos carga. Esto libera capacidad para instalar equipos adicionales sin necesidad de mejorar la infraestructura. A veces, la capacidad liberada por s\u00ed sola ya justifica la inversi\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b50029 elementor-widget elementor-widget-heading\" data-id=\"9b50029\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Menor n\u00famero de p\u00e9rdidas<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e0dad3 elementor-widget elementor-widget-text-editor\" data-id=\"8e0dad3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>La corriente que circula por los conductores genera calor, lo que supone una p\u00e9rdida de energ\u00eda. Dado que un banco de condensadores reduce la corriente total, las p\u00e9rdidas disminuyen en todo el sistema. Los cables se calientan menos. Los transformadores funcionan con mayor eficiencia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3517a7 elementor-widget elementor-widget-heading\" data-id=\"b3517a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tensi\u00f3n mejorada<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3f4dd00 elementor-widget elementor-widget-text-editor\" data-id=\"3f4dd00\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Una corriente reactiva excesiva contribuye a la ca\u00edda de tensi\u00f3n. Con la compensaci\u00f3n adecuada, la tensi\u00f3n en los terminales de carga mejora. Los motores funcionan mejor. Los equipos sensibles operan de manera m\u00e1s confiable.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e457e74 elementor-widget elementor-widget-heading\" data-id=\"e457e74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Sizing_Considerations_for_Effective_Power_Factor_Improvement\"><\/span>Consideraciones sobre el dimensionamiento para una mejora eficaz del factor de potencia<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c34b40 elementor-widget elementor-widget-heading\" data-id=\"8c34b40\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Factor de potencia objetivo<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-119d02b elementor-widget elementor-widget-text-editor\" data-id=\"119d02b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>La mayor\u00eda de las instalaciones se fijan como objetivo un valor de entre 0,95 y 0,98 tras la correcci\u00f3n. Un valor superior a 0,98 ofrece rendimientos decrecientes. Algunas empresas de servicios p\u00fablicos penalizan el factor de potencia adelantado, por lo que una correcci\u00f3n excesiva conlleva riesgos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8a5badf elementor-widget elementor-widget-heading\" data-id=\"8a5badf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">M\u00e9todo de c\u00e1lculo<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e586512 elementor-widget elementor-widget-text-editor\" data-id=\"e586512\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>El enfoque b\u00e1sico consiste en:<\/p><ol><li>Medir la demanda de potencia real actual<\/li><li>Medir el factor de potencia actual<\/li><li>Determinar el factor de potencia objetivo<\/li><li>Calcular los kVAR necesarios utilizando f\u00f3rmulas o tablas est\u00e1ndar<\/li><\/ol><p>El dimensionamiento adecuado tambi\u00e9n tiene en cuenta las variaciones de carga, la expansi\u00f3n futura y las condiciones arm\u00f3nicas. Un banco de condensadores dimensionado \u00fanicamente para las cargas actuales puede resultar insuficiente a medida que las instalaciones crecen. Si desea obtener m\u00e1s informaci\u00f3n sobre los bancos de condensadores, lea <a href=\"https:\/\/zmgs-global.com\/es\/what-is-the-use-of-capacitor-bank.html\/\"><strong>\u00bfPara qu\u00e9 sirve un banco de condensadores?<\/strong><\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d9ec60 elementor-widget elementor-widget-heading\" data-id=\"5d9ec60\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"FAQ\"><\/span>Preguntas frecuentes<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a0acd6 elementor-widget elementor-widget-n-accordion\" data-id=\"4a0acd6\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Acorde\u00f3n. Abre los enlaces con la tecla Intro o la barra espaciadora, ci\u00e9rralos con la tecla Esc y navega con las teclas de flecha\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7760\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-7760\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfEn cu\u00e1nto tiempo se amortiza un banco de condensadores gracias a la mejora del factor de potencia? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7760\" class=\"elementor-element elementor-element-fe5539a e-con-full e-flex e-con e-child\" data-id=\"fe5539a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-64b5f47 elementor-widget elementor-widget-text-editor\" data-id=\"64b5f47\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>El plazo de amortizaci\u00f3n suele oscilar entre uno y tres a\u00f1os, aunque en ocasiones puede ser m\u00e1s corto en instalaciones con cargas reactivas importantes y sanciones por parte de la empresa de servicios p\u00fablicos. El c\u00e1lculo depende de las tarifas el\u00e9ctricas, el factor de potencia actual y los costos de instalaci\u00f3n. Las instalaciones que pagan sanciones sustanciales por el factor de potencia suelen obtener un retorno de la inversi\u00f3n en un plazo de 12 a 18 meses. Incluso sin sanciones directas, la reducci\u00f3n de los cargos por demanda y de las p\u00e9rdidas del sistema contribuyen a la amortizaci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7761\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7761\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfPuede un banco de condensadores corregir en exceso el factor de potencia? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7761\" class=\"elementor-element elementor-element-77f11e4 e-con-full e-flex e-con e-child\" data-id=\"77f11e4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-445a599 elementor-widget elementor-widget-text-editor\" data-id=\"445a599\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>S\u00ed, y esto genera problemas. La sobrecorrecci\u00f3n hace que el factor de potencia pase a ser adelantado, lo que significa que la instalaci\u00f3n exporta potencia reactiva a la red. Algunas empresas de servicios p\u00fablicos penalizan el factor de potencia adelantado de la misma manera que penalizan el atrasado. La sobrecorrecci\u00f3n tambi\u00e9n puede provocar aumentos de tensi\u00f3n y problemas de resonancia. Los sistemas autom\u00e1ticos de bancos de condensadores con controles adecuados evitan la sobrecorrecci\u00f3n al ajustar la compensaci\u00f3n a la demanda real.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-7762\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-7762\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfFunciona un banco de condensadores con todo tipo de cargas el\u00e9ctricas? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-7762\" class=\"elementor-element elementor-element-cde18f5 e-con-full e-flex e-con e-child\" data-id=\"cde18f5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c02d3c4 elementor-widget elementor-widget-text-editor\" data-id=\"c02d3c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Los bancos de condensadores corrigen principalmente las cargas inductivas \u2014motores, transformadores, balastos magn\u00e9ticos\u2014. No mejoran el factor de potencia de las cargas resistivas (elementos calefactores, iluminaci\u00f3n incandescente), ya que estas ya funcionan con un factor de potencia unitario. Las cargas no lineales, como los variadores de frecuencia, requieren una atenci\u00f3n especial. Los condensadores est\u00e1ndar pueden amplificar los arm\u00f3nicos procedentes de estas fuentes, lo que podr\u00eda causar m\u00e1s problemas de los que resuelven. Los sistemas desintonizados o filtrados son adecuados para estas aplicaciones.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"The Connection Between a Capacitor Bank and Power Factor Electricity bills keep climbing. For industrial and commercial facilities, power factor penalties often add insult to injury\u2014extra charges for using power inefficiently. The solution sitting in countless electrical rooms? A capacitor bank. This technology has been around for decades. Nothing revolutionary about it. Yet many facility [&hellip;]","protected":false},"author":8,"featured_media":1390,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[46],"tags":[],"class_list":["post-2171","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-guide"],"acf":[],"_links":{"self":[{"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/posts\/2171","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/comments?post=2171"}],"version-history":[{"count":0,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/posts\/2171\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/media\/1390"}],"wp:attachment":[{"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/media?parent=2171"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/categories?post=2171"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/tags?post=2171"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}