{"id":2155,"date":"2026-02-10T14:51:12","date_gmt":"2026-02-10T06:51:12","guid":{"rendered":"https:\/\/zmgs-global.com\/?p=2155"},"modified":"2026-02-26T11:12:17","modified_gmt":"2026-02-26T03:12:17","slug":"how-to-check-if-a-capacitor-bank-is-working","status":"publish","type":"post","link":"https:\/\/zmgs-global.com\/es\/how-to-check-if-a-capacitor-bank-is-working.html","title":{"rendered":"\u00bfC\u00f3mo comprobar si un banco de condensadores funciona o no?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2155\" class=\"elementor elementor-2155\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-acf3dd7 e-flex e-con-boxed e-con e-parent\" data-id=\"acf3dd7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-de783d6 elementor-widget elementor-widget-text-editor\" data-id=\"de783d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Un banco de condensadores que no funciona correctamente no solo supone un desperdicio de dinero. Impide corregir el factor de potencia, hace que se acumulen las multas de la empresa de servicios p\u00fablicos y puede generar riesgos de seguridad. Sin embargo, muchas instalaciones funcionan durante a\u00f1os sin que nadie compruebe realmente si funcionan correctamente.<\/p><p>La cuesti\u00f3n de c\u00f3mo comprobar si un <a href=\"https:\/\/zmgs-global.com\/es\/products\/\"><strong>banco de condensadores<\/strong> <\/a>El funcionamiento parece sencillo. En la pr\u00e1ctica, implica varios m\u00e9todos diferentes, desde la simple observaci\u00f3n visual hasta mediciones el\u00e9ctricas detalladas. Algunas comprobaciones se realizan en cuesti\u00f3n de minutos con herramientas b\u00e1sicas. Otras requieren equipo especializado y conocimientos t\u00e9cnicos.<\/p><p>Saber en qu\u00e9 fijarse y cu\u00e1ndo recurrir a la ayuda de un profesional garantiza que las instalaciones de bancos de condensadores funcionen seg\u00fan lo previsto.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b6da43 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"4b6da43\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/High-Voltage-Shunt-Power-Capacitor.webp\" class=\"attachment-full size-full wp-image-1593\" alt=\"Condensador de potencia de alta tensi\u00f3n\" srcset=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/High-Voltage-Shunt-Power-Capacitor.webp 400w, https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/High-Voltage-Shunt-Power-Capacitor-150x150.webp 150w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4eebb53 elementor-widget elementor-widget-heading\" data-id=\"4eebb53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/zmgs-global.com\/es\/how-to-check-if-a-capacitor-bank-is-working.html\/#Visual_Inspection_of_a_Capacitor_Bank\" >Inspecci\u00f3n visual de un banco de condensadores<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/zmgs-global.com\/es\/how-to-check-if-a-capacitor-bank-is-working.html\/#Electrical_Testing_Methods_for_Capacitor_Bank_Verification\" >M\u00e9todos de ensayo el\u00e9ctrico para la verificaci\u00f3n de bancos de condensadores<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/zmgs-global.com\/es\/how-to-check-if-a-capacitor-bank-is-working.html\/#Monitoring_Capacitor_Bank_Performance_Over_Time\" >Supervisi\u00f3n del rendimiento de los bancos de condensadores a lo largo del tiempo<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/zmgs-global.com\/es\/how-to-check-if-a-capacitor-bank-is-working.html\/#FAQ\" >Preguntas frecuentes<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Visual_Inspection_of_a_Capacitor_Bank\"><\/span>Inspecci\u00f3n visual de un banco de condensadores<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-32a29c7 elementor-widget elementor-widget-heading\" data-id=\"32a29c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Qu\u00e9 hay que tener en cuenta en el aspecto externo<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28c64f2 elementor-widget elementor-widget-text-editor\" data-id=\"28c64f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>La inspecci\u00f3n visual permite detectar una cantidad sorprendente de problemas, siempre y cuando se realice con regularidad. El estado f\u00edsico de los condensadores revela mucho sobre su estado interno.<\/p><p>Las se\u00f1ales de advertencia visibles desde el exterior incluyen:<\/p><ul><li>Abombamiento o hinchaz\u00f3n de las carcasas de los condensadores<\/li><li>Fugas de aceite alrededor de las juntas o en las uniones de la carcasa<\/li><li>Marcas de quemaduras o decoloraci\u00f3n en las carcasas<\/li><li>Corrosi\u00f3n en terminales y conexiones<\/li><li>Aislamiento del cableado da\u00f1ado o deteriorado<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-16b01ab elementor-widget elementor-widget-heading\" data-id=\"16b01ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Condiciones ambientales y de montaje<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b793833 elementor-widget elementor-widget-text-editor\" data-id=\"b793833\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>M\u00e1s all\u00e1 de las propias unidades de condensadores, el estado general de la instalaci\u00f3n es importante. La acumulaci\u00f3n de polvo reduce la eficiencia de refrigeraci\u00f3n. Las aberturas de ventilaci\u00f3n obstruidas provocan sobrecalentamiento. Un montaje flojo puede provocar da\u00f1os por vibraci\u00f3n con el paso del tiempo.<\/p><p>Una evaluaci\u00f3n ambiental r\u00e1pida incluye comprobar:<\/p><ol><li>Las v\u00edas de ventilaci\u00f3n deben permanecer despejadas y sin obstrucciones<\/li><li>La temperatura ambiente se mantiene dentro de los l\u00edmites especificados<\/li><li>No hay filtraciones de agua ni humedad excesiva<\/li><li>Las conexiones siguen bien ajustadas, sin signos de calentamiento<\/li><li>Los dispositivos de protecci\u00f3n parecen estar intactos y correctamente configurados<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94872fa elementor-widget elementor-widget-heading\" data-id=\"94872fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Electrical_Testing_Methods_for_Capacitor_Bank_Verification\"><\/span>M\u00e9todos de ensayo el\u00e9ctrico para la verificaci\u00f3n de bancos de condensadores<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80eb90c elementor-widget elementor-widget-heading\" data-id=\"80eb90c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Mediciones b\u00e1sicas de corriente<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c0eeee6 elementor-widget elementor-widget-text-editor\" data-id=\"c0eeee6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<table><tbody><tr><td><p><strong><b>Resultado de la prueba<\/b><\/strong><\/p><\/td><td><p><strong><b>Posible interpretaci\u00f3n<\/b><\/strong><\/p><\/td><\/tr><tr><td><p>La corriente se encuentra en el nivel previsto<\/p><\/td><td><p>Es probable que el banco de condensadores funcione con normalidad<\/p><\/td><\/tr><tr><td><p>Corriente significativamente baja<\/p><\/td><td><p>Algunos elementos se han quedado abiertos<\/p><\/td><\/tr><tr><td><p>Corriente superior a la prevista<\/p><\/td><td><p>Posibles problemas de arm\u00f3nicos o error de medici\u00f3n<\/p><\/td><\/tr><tr><td><p>Sin consumo de corriente<\/p><\/td><td><p>Fallo total, fusible fundido o contactor abierto<\/p><\/td><\/tr><tr><td><p>Corrientes de fase desequilibradas<\/p><\/td><td><p>Fallas en los componentes internos de una o m\u00e1s fases<\/p><\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3565aa0 elementor-widget elementor-widget-text-editor\" data-id=\"3565aa0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Un amper\u00edmetro de pinza permite realizar esta comprobaci\u00f3n de forma r\u00e1pida y sin necesidad de intervenir en el sistema. Compare los valores medidos con los valores nominales indicados en la placa de caracter\u00edsticas, ajustados al voltaje real. La corriente debe ser proporcional: un voltaje m\u00e1s bajo implica una corriente m\u00e1s baja, mientras que un voltaje m\u00e1s alto implica una corriente m\u00e1s alta.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f2bb3c elementor-widget elementor-widget-heading\" data-id=\"1f2bb3c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Pruebas de capacitancia y factor de potencia<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb4e13f elementor-widget elementor-widget-text-editor\" data-id=\"eb4e13f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Para realizar una evaluaci\u00f3n m\u00e1s detallada, es necesario medir los valores reales de capacitancia y compararlos con las especificaciones indicadas en la placa de identificaci\u00f3n. Las pruebas de capacitancia permiten identificar las unidades deterioradas antes de que se produzca una falla total.<\/p><p>Las pruebas del factor de potencia \u2014en concreto, la medici\u00f3n del factor de disipaci\u00f3n o tan delta\u2014 revelan el estado del diel\u00e9ctrico. Los condensadores en buen estado presentan un factor de disipaci\u00f3n muy bajo. El aumento de estos valores indica envejecimiento o contaminaci\u00f3n, lo que con el tiempo conduce a una falla.<\/p><p>Estas pruebas suelen requerir:<\/p><ul><li>El banco de condensadores debe desenergizarse y aislarse<\/li><li>Se han completado los procedimientos de descarga adecuados<\/li><li>Equipos de prueba especializados (capac\u00edmetro, equipo de medici\u00f3n del factor de potencia)<\/li><li>Conocimientos t\u00e9cnicos para interpretar correctamente los resultados<\/li><\/ul><p>La mayor\u00eda de las instalaciones carecen de equipos para realizar pruebas de capacitancia in situ. Realizar pruebas peri\u00f3dicas a cargo de contratistas calificados resulta m\u00e1s conveniente que adquirir instrumentos especializados que solo se utilizan de vez en cuando.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f380137 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"f380137\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/high-voltage-power-capacitor-400x400-c.webp\" class=\"attachment-full size-full wp-image-1589\" alt=\"condensador trif\u00e1sico\" srcset=\"https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/high-voltage-power-capacitor-400x400-c.webp 400w, https:\/\/zmgs-global.com\/wp-content\/uploads\/2025\/12\/high-voltage-power-capacitor-400x400-c-150x150.webp 150w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f1c32f9 elementor-widget elementor-widget-heading\" data-id=\"f1c32f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\"> Evaluaci\u00f3n por termograf\u00eda<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-05d6bbf elementor-widget elementor-widget-text-editor\" data-id=\"05d6bbf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>La termograf\u00eda infrarroja se ha convertido en una herramienta indispensable para la evaluaci\u00f3n de bancos de condensadores. Los puntos calientes revelan problemas invisibles a simple vista: conexiones sueltas, elementos sobrecargados y fallas internas que generan calor.<\/p><p>El escaneo t\u00e9rmico funciona mejor durante el funcionamiento normal, en condiciones de carga habituales. La comparaci\u00f3n de temperaturas entre componentes similares permite identificar valores at\u00edpicos. Un condensador que se caliente mucho m\u00e1s que los que lo rodean justifica una investigaci\u00f3n, incluso sin que haya otros s\u00edntomas evidentes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-134b5bf elementor-widget elementor-widget-heading\" data-id=\"134b5bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"Monitoring_Capacitor_Bank_Performance_Over_Time\"><\/span>Supervisi\u00f3n del rendimiento de los bancos de condensadores a lo largo del tiempo<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db800ae elementor-widget elementor-widget-heading\" data-id=\"db800ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Seguimiento de las tendencias del factor de potencia<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53c7375 elementor-widget elementor-widget-text-editor\" data-id=\"53c7375\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Quiz\u00e1s la comprobaci\u00f3n continua m\u00e1s pr\u00e1ctica consista simplemente en supervisar el factor de potencia en el medidor de la compa\u00f1\u00eda el\u00e9ctrica o en el cuadro el\u00e9ctrico principal. Si el factor de potencia se mantiene en los niveles deseados, es de suponer que el banco de condensadores est\u00e1 funcionando correctamente. Si el factor de potencia va disminuyendo con el tiempo, es que algo ha cambiado.<\/p><p>Las facturas de servicios p\u00fablicos suelen incluir datos sobre el factor de potencia cada mes. El seguimiento de esta informaci\u00f3n permite detectar un deterioro gradual que, de otro modo, podr\u00eda pasar desapercibido. Los cambios repentinos requieren una investigaci\u00f3n inmediata.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1541b53 elementor-widget elementor-widget-heading\" data-id=\"1541b53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Diagn\u00f3stico autom\u00e1tico del sistema<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5113bd1 elementor-widget elementor-widget-text-editor\" data-id=\"5113bd1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Los bancos de condensadores autom\u00e1ticos modernos incluyen controladores que supervisan su propio funcionamiento. Las salidas de alarma indican situaciones de fallo. Los registros de funcionamiento recogen la actividad de conmutaci\u00f3n y los par\u00e1metros medidos. Las interfaces de comunicaci\u00f3n permiten la supervisi\u00f3n remota.<\/p><p>Aprovechar estas funciones de diagn\u00f3stico integradas \u2014es decir, analizar los datos en lugar de ignorarlos\u2014 permite detectar los problemas a tiempo. Muchas fallas dan se\u00f1ales de advertencia que se reflejan en las tendencias de funcionamiento mucho antes de que aparezcan s\u00edntomas evidentes. Si desea obtener m\u00e1s informaci\u00f3n sobre los bancos de condensadores, lea <a href=\"https:\/\/zmgs-global.com\/es\/what-is-the-lifespan-of-a-capacitor-bank.html\/\"><strong>\u00bfCu\u00e1l es la vida \u00fatil de un banco de condensadores?<\/strong><\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4476aff elementor-widget elementor-widget-heading\" data-id=\"4476aff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span class=\"ez-toc-section\" id=\"FAQ\"><\/span>Preguntas frecuentes<span class=\"ez-toc-section-end\"><\/span><\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18d497a elementor-widget elementor-widget-n-accordion\" data-id=\"18d497a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Acorde\u00f3n. Abre los enlaces con la tecla Intro o la barra espaciadora, ci\u00e9rralos con la tecla Esc y navega con las teclas de flecha\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2600\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-2600\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfCon qu\u00e9 frecuencia se debe inspeccionar un banco de condensadores? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2600\" class=\"elementor-element elementor-element-a6d1ae2 e-con-full e-flex e-con e-child\" data-id=\"a6d1ae2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0bbf866 elementor-widget elementor-widget-text-editor\" data-id=\"0bbf866\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>La frecuencia de las inspecciones depende del entorno operativo y del nivel de importancia de la instalaci\u00f3n. La mayor\u00eda de las instalaciones industriales se benefician de una inspecci\u00f3n visual trimestral y de una evaluaci\u00f3n el\u00e9ctrica m\u00e1s detallada una vez al a\u00f1o. Los entornos hostiles \u2014altas temperaturas, condiciones polvorientas, alta carga arm\u00f3nica\u2014 requieren una atenci\u00f3n m\u00e1s frecuente, tal vez con revisiones visuales mensuales. Las instalaciones de servicios p\u00fablicos suelen seguir los programas de mantenimiento especificados por las normas de confiabilidad. La clave es la constancia, m\u00e1s que una atenci\u00f3n ocasional y aleatoria.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2601\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2601\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfSe puede realizar una prueba en un banco de condensadores mientras est\u00e1 energizado? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2601\" class=\"elementor-element elementor-element-e65e8b7 e-con-full e-flex e-con e-child\" data-id=\"e65e8b7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e278241 elementor-widget elementor-widget-text-editor\" data-id=\"e278241\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Algunas pruebas pueden realizarse de forma segura en equipos bajo tensi\u00f3n, mientras que otras requieren obligatoriamente que se desconecte la tensi\u00f3n. La medici\u00f3n de corriente con amper\u00edmetros de pinza se realiza de manera segura con la t\u00e9cnica adecuada y el equipo de protecci\u00f3n personal apropiado. La termograf\u00eda requiere espec\u00edficamente que el equipo est\u00e9 energizado y bajo carga. Sin embargo, las pruebas de capacitancia y la inspecci\u00f3n interna requieren la desconexi\u00f3n total de la energ\u00eda, procedimientos adecuados de bloqueo y etiquetado, y la descarga verificada de la energ\u00eda almacenada. Los condensadores retienen la carga incluso despu\u00e9s de la desconexi\u00f3n; deben descargarse a trav\u00e9s de resistencias adecuadas antes de realizar cualquier trabajo manual.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2602\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2602\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 indica que un banco de condensadores necesita ser reemplazado en lugar de reparado? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-minus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h384c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-plus\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M416 208H272V64c0-17.67-14.33-32-32-32h-32c-17.67 0-32 14.33-32 32v144H32c-17.67 0-32 14.33-32 32v32c0 17.67 14.33 32 32 32h144v144c0 17.67 14.33 32 32 32h32c17.67 0 32-14.33 32-32V304h144c17.67 0 32-14.33 32-32v-32c0-17.67-14.33-32-32-32z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2602\" class=\"elementor-element elementor-element-57434bf e-con-full e-flex e-con e-child\" data-id=\"57434bf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-15ac788 elementor-widget elementor-widget-text-editor\" data-id=\"15ac788\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Hay varios factores que inclinan la balanza hacia la sustituci\u00f3n. Cuando varias unidades de condensadores han fallado en un breve periodo de tiempo, es probable que las unidades restantes, de edad similar, est\u00e9n a punto de fallar, por lo que seguir sustituyendo unidades individuales deja de ser viable. Si el banco de condensadores utiliza materiales diel\u00e9ctricos obsoletos o contiene PCB, la sustituci\u00f3n es obligatoria independientemente de su estado operativo. Cuando los costos de reparaci\u00f3n se acercan al 50-60 % del costo de sustituci\u00f3n, resulta m\u00e1s rentable invertir en equipo nuevo con garant\u00eda vigente y dise\u00f1o moderno.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"A capacitor bank that isn&#8217;t working properly does more than just waste money. It leaves power factor uncorrected, allows utility penalties to accumulate, and potentially creates safety hazards. Yet many installations run for years without anyone actually verifying proper operation. The question of how to check if a capacitor bank is working seems straightforward. In [&hellip;]","protected":false},"author":8,"featured_media":760,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[47],"tags":[],"class_list":["post-2155","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowledge"],"acf":[],"_links":{"self":[{"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/posts\/2155","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/comments?post=2155"}],"version-history":[{"count":0,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/posts\/2155\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/media\/760"}],"wp:attachment":[{"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/media?parent=2155"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/categories?post=2155"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zmgs-global.com\/es\/wp-json\/wp\/v2\/tags?post=2155"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}