{"id":156,"date":"2025-08-08T16:16:49","date_gmt":"2025-08-08T08:16:49","guid":{"rendered":"https:\/\/mediumslateblue-chimpanzee-835813.hostingersite.com\/product\/low-valtage-shunt-capacitor-of-the-self-healing-2"},"modified":"2025-12-23T10:34:41","modified_gmt":"2025-12-23T02:34:41","slug":"high-voltage-start-shunt-electrical-reactor","status":"publish","type":"product","link":"https:\/\/zmgs-global.com\/ar\/product\/high-voltage-start-shunt-electrical-reactor","title":{"rendered":"High Voltage Start Shunt Electrical Reactor"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u062c\u062f\u0648\u0644 \u0627\u0644\u0645\u062d\u062a\u0648\u064a\u0627\u062a<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/zmgs-global.com\/ar\/product\/high-voltage-start-shunt-electrical-reactor\/#Code_and_implication\" >Code and implication<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/zmgs-global.com\/ar\/product\/high-voltage-start-shunt-electrical-reactor\/#Application\" >\u0627\u0644\u062a\u0637\u0628\u064a\u0642<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/zmgs-global.com\/ar\/product\/high-voltage-start-shunt-electrical-reactor\/#Normal_ambient_condition\" >Normal ambient condition<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/zmgs-global.com\/ar\/product\/high-voltage-start-shunt-electrical-reactor\/#Main_Technical_Data\" >Main Technical Data<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/zmgs-global.com\/ar\/product\/high-voltage-start-shunt-electrical-reactor\/#Specification_Dimensions\" >Specification &amp; Dimensions<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/zmgs-global.com\/ar\/product\/high-voltage-start-shunt-electrical-reactor\/#Wiring_Diagram\" >Wiring Diagram<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Code_and_implication\"><\/span><strong>Code and implication<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image is-resized\"><img decoding=\"async\" src=\"https:\/\/www.zmgs-global.com\/static\/upload\/image\/20250321\/1742546271188089.jpg\" alt=\"12.jpg\" style=\"width:662px;height:auto\"\/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Application\"><\/span><strong>\u0627\u0644\u062a\u0637\u0628\u064a\u0642<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><strong>ZHIMING\u00a0\u00a0<\/strong>brand of\u00a0QKSG\/QKSC dry-core starter high voltage start shunt electrical reactors utilizes premium imported silicon steel laminations. The core design features uniformly segmented columns with multiple epoxy-insulated air gaps, bonded using high-temperature structural adhesives to maintain gap stability during operation.<br>Core end faces are treated with specialized silicon steel adhesive, ensuring rigid lamination bonding that significantly reduces operational noise while enhancing corrosion resistance.<br>Coils employ encapsulated winding technology, with primary insulation vacuum-impregnated using high-temperature insulating varnish. This process delivers exceptional dielectric properties, high mechanical integrity, and resistance to cracking under motor starting inrush currents and thermal shocks.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Normal_ambient_condition\"><\/span><strong>Normal ambient condition<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Altitude: &lt;1000m<br>Working temperature: -25~+45\u00b0C<br>The mounting site is free from fire hazards, explosion risks, flooding, strong chemical corrosion, and similar dangers. Following each start, the equipment must cool for 6 hours before restarting.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Main_Technical_Data\"><\/span><strong>Main Technical Data<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>\u25cf The dry start reactor is smaller than the traditional oil-immersed reactor and air core reactor. Small, lightweight, small footprint, simple structure, easy installation. Features;<br>\u25cfThe temperature resistance level reaches F grade(155\u00b0C);<br>\u25cfThe dry core starter reactor loss is lower than that of the oil-immersed reactor;<br>\u25cfThe noise of the dry core starter reactor is not greater than the national standard (65dB).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Specification_Dimensions\"><\/span><strong>Specification &amp; Dimensions<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Type<\/td><td>Start capacity<\/td><td>Rated voltage<\/td><td>Dimension <br>L x W x H<\/td><td>Driven motor power<\/td><\/tr><tr><td>QKSG-220<\/td><td>393&nbsp;<\/td><td rowspan=\"17\">6kV,10kV<\/td><td>760x400x835<\/td><td>&nbsp;&nbsp; 220&nbsp;<\/td><\/tr><tr><td>QKSG-250<\/td><td>445&nbsp;<\/td><td>760x400x835<\/td><td>&nbsp;&nbsp; 250&nbsp;<\/td><\/tr><tr><td>QKSG-280<\/td><td>493&nbsp;<\/td><td>760x400x835<\/td><td>&nbsp;&nbsp; 280&nbsp;<\/td><\/tr><tr><td>QKSG-315<\/td><td>553&nbsp;<\/td><td>805x450x875<\/td><td>&nbsp;&nbsp; 315&nbsp;<\/td><\/tr><tr><td>QKSG-355<\/td><td>620&nbsp;<\/td><td>805x450x875<\/td><td>&nbsp;&nbsp; 355&nbsp;<\/td><\/tr><tr><td>QKSG-400<\/td><td>700&nbsp;<\/td><td>805x450x875<\/td><td>&nbsp;&nbsp; 400&nbsp;<\/td><\/tr><tr><td>QKSG-450<\/td><td>787&nbsp;<\/td><td>865x450x920<\/td><td>&nbsp;&nbsp; 450&nbsp;<\/td><\/tr><tr><td>QKSG-500<\/td><td>854&nbsp;<\/td><td>865x450x920<\/td><td>&nbsp;&nbsp; 500&nbsp;<\/td><\/tr><tr><td>QKSG-560<\/td><td>963&nbsp;<\/td><td>865x450x920<\/td><td>&nbsp;&nbsp; 560&nbsp;<\/td><\/tr><tr><td>QKSG-630<\/td><td>1081&nbsp;<\/td><td>865x450x920<\/td><td>&nbsp;&nbsp; 630&nbsp;<\/td><\/tr><tr><td>QKSG-710<\/td><td>1215&nbsp;<\/td><td>865x450x920<\/td><td>&nbsp;&nbsp; 710&nbsp;<\/td><\/tr><tr><td>QKSG-800<\/td><td>1366&nbsp;<\/td><td>895x450x960<\/td><td>&nbsp;&nbsp; 800&nbsp;<\/td><\/tr><tr><td>QKSG-900<\/td><td>1538&nbsp;<\/td><td>895x450x960<\/td><td>&nbsp;&nbsp; 900&nbsp;<\/td><\/tr><tr><td>QKSG-1000<\/td><td>1844&nbsp;<\/td><td>895x450x960<\/td><td>&nbsp;&nbsp; 1000&nbsp;<\/td><\/tr><tr><td>QKSG-1120<\/td><td>2040&nbsp;<\/td><td>955x450x1015<\/td><td>&nbsp;&nbsp; 1120&nbsp;<\/td><\/tr><tr><td>QKSG-1250<\/td><td>2273&nbsp;<\/td><td>955x450x1015<\/td><td>&nbsp;&nbsp; 1250&nbsp;<\/td><\/tr><tr><td>QKSG-1400<\/td><td>2543&nbsp;<\/td><td>955x450x1015<\/td><td>&nbsp;&nbsp; 1400&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Note: <\/strong>Other special specification models are supplied according to user requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wiring_Diagram\"><\/span>Wiring Diagram<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p><img decoding=\"async\" src=\"https:\/\/www.zmgs-global.com\/static\/upload\/image\/20250610\/1749541558173210.png\" alt=\"image.png\"><\/p>","protected":false},"excerpt":{"rendered":"Code and implication Application ZHIMING\u00a0\u00a0brand of\u00a0QKSG\/QKSC dry-core starter high voltage start shunt electrical reactors utilizes premium imported silicon steel laminations. The core design features uniformly segmented columns with multiple epoxy-insulated air gaps, bonded using high-temperature structural adhesives to maintain gap stability during operation.Core end faces are treated with specialized silicon steel adhesive, ensuring rigid lamination [&hellip;]","protected":false},"featured_media":267,"menu_order":0,"template":"","meta":[],"products":[14],"class_list":["post-156","product","type-product","status-publish","has-post-thumbnail","hentry","products-high-voltage-power-reactor"],"acf":[],"_links":{"self":[{"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/product\/156","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/product\/156\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/media\/267"}],"wp:attachment":[{"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/media?parent=156"}],"wp:term":[{"taxonomy":"products","embeddable":true,"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/products?post=156"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}