{"id":1136,"date":"2025-10-25T10:30:00","date_gmt":"2025-10-25T02:30:00","guid":{"rendered":"https:\/\/zmgs-global.com\/?post_type=product&#038;p=1136"},"modified":"2025-12-22T14:51:14","modified_gmt":"2025-12-22T06:51:14","slug":"ggd-low-voltage-reactive-power-compensation-cabinet","status":"publish","type":"product","link":"https:\/\/zmgs-global.com\/ar\/product\/ggd-low-voltage-reactive-power-compensation-cabinet","title":{"rendered":"GGD Low Voltage Reactive Power Compensation Cabinet"},"content":{"rendered":"<h1 class=\"wp-block-heading\"><strong>Product Overview<\/strong><\/h1>\n\n\n\n<p>The <strong>GGD Low Voltage Reactive Power Compensation Cabinet<\/strong> is a fixed installation type power distribution and reactive compensation device designed for AC 50\/60 Hz systems with rated operating voltage up to 690 V.<br>It is mainly used for industrial and commercial power distribution networks to <strong>improve power factor<\/strong>, <strong>reduce reactive current<\/strong>, <strong>stabilize voltage<\/strong>, and <strong>enhance overall power quality<\/strong>.<\/p>\n\n\n\n<p>The cabinet adopts a modular design with reliable electrical performance, convenient maintenance, and strong adaptability to various load conditions.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\"><strong>Main Functions<\/strong><\/h1>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Automatic Power Factor Compensation:<\/strong> Equipped with intelligent reactive power controller to automatically switch capacitor banks according to load changes.<\/li>\n\n\n\n<li><strong>Voltage Stabilization:<\/strong> Reduces voltage drops in distribution lines and improves power supply quality.<\/li>\n\n\n\n<li><strong>Energy Saving:<\/strong> Decreases line losses and transformer loading, effectively reducing energy consumption.<\/li>\n\n\n\n<li><strong>Protection Functions:<\/strong> Provides overvoltage, undervoltage, overcurrent, and phase-loss protection.<\/li>\n\n\n\n<li><strong>Real-Time Monitoring:<\/strong> Front panel instruments display voltage, current, power factor, and other electrical parameters.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h1 class=\"wp-block-heading\"><strong>Technical Specifications<\/strong><\/h1>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Item<\/th><th>Specification<\/th><\/tr><\/thead><tbody><tr><td><strong>Rated Voltage<\/strong><\/td><td>AC 380 V \/ 400 V \/ 415 V (customizable up to 690 V)<\/td><\/tr><tr><td><strong>Rated Frequency<\/strong><\/td><td>50 Hz \/ 60 Hz<\/td><\/tr><tr><td><strong>Rated Compensation Capacity<\/strong><\/td><td>30 \u2013 1000 kvar (modular combination)<\/td><\/tr><tr><td><strong>Control Mode<\/strong><\/td><td>Automatic \/ Manual (via intelligent controller)<\/td><\/tr><tr><td><strong>Protection Class<\/strong><\/td><td>IP30 ~ IP40 (depending on configuration)<\/td><\/tr><tr><td><strong>Ambient Temperature<\/strong><\/td><td>\u221225 \u00b0C ~ +45 \u00b0C<\/td><\/tr><tr><td><strong>Cooling Method<\/strong><\/td><td>Natural ventilation or forced air cooling<\/td><\/tr><tr><td><strong>Installation Type<\/strong><\/td><td>Indoor floor-standing, front operation and maintenance<\/td><\/tr><tr><td><strong>Standard Compliance<\/strong><\/td><td>IEC 61439-2, GB 7251.12-2013 (Low-voltage switchgear and controlgear assemblies)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h1 class=\"wp-block-heading\"><strong>\u0627\u0644\u0645\u0632\u0627\u064a\u0627<\/strong><\/h1>\n\n\n\n<p>\u2705 Stable and reliable operation<br>\u2705 Easy installation and modular expansion<br>\u2705 Intelligent control with automatic switching<br>\u2705 Compatible with harmonic suppression components<br>\u2705 Extended equipment life and reduced operating cost<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"Product Overview The GGD Low Voltage Reactive Power Compensation Cabinet is a fixed installation type power distribution and reactive compensation device designed for AC 50\/60 Hz systems with rated operating voltage up to 690 V.It is mainly used for industrial and commercial power distribution networks to improve power factor, reduce reactive current, stabilize voltage, and [&hellip;]","protected":false},"featured_media":1137,"menu_order":0,"template":"","meta":[],"products":[28],"class_list":["post-1136","product","type-product","status-publish","has-post-thumbnail","hentry","products-panel-cabinet"],"acf":[],"_links":{"self":[{"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/product\/1136","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/product\/1136\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/media\/1137"}],"wp:attachment":[{"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/media?parent=1136"}],"wp:term":[{"taxonomy":"products","embeddable":true,"href":"https:\/\/zmgs-global.com\/ar\/wp-json\/wp\/v2\/products?post=1136"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}